Eaton Crouse-Hinds EIDC3200 S214 S784 Disconnect Switch - Hazardous Locations
Part Number: EIDC3200 S214 S784
Manufacturer
Eaton Crouse-Hinds
Part number
EIDC3200 S214 S784
Quick Summary
The EID disconnect switch is a rugged isolation device designed for hazardous-location motor control in industrial plants. It delivers safe electrical isolation in Class I, Zone 2 and other classified locations, reducing arc flash risk during maintenance. This model carries NEC/CEC compliance and multiple NEMA ratings (4, 7, 9, 3R), supporting reliable operation in harsh environments. Procurement teams rely on its copper-free aluminum housing, 200 A amperage rating, and non-fused design to simplify compliance and reduce spare-part costs. By integrating auxiliary contacts and an external ground lug, it enables straightforward integration with 240-600 VAC systems while maintaining essential HP options and longevity in demanding industrial settings.
Product Information
Extended Description
EIDC3200 S214 S784 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EID disconnect switch, 200A, With switch, Non-fused, 15 HP/75 HP/150 HP/200 HP, Copper-free aluminum, Auxiliary contact (single block), external ground lug, 240-600 Vac/250 Vdc
Product Name
Eaton Crouse-Hinds series EID disconnect switch
Catalog Number
EIDC3200 S214 S784
Product Length/Depth
17.44 in
Product Height
29.44 in
Product Width
13.19 in
Product Weight
149 lb
UPC
662276708112
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Zone 2 Class II, Division 1 Class III Class I, Division 1 Class I, Zone 1 Class I, Division 2
NEMA Rating
4 7 9 3 3R
Enclosure type
With switch
Fusing
Non-fused
Amperage Rating
200A
Horsepower
15 hp/75 hp/150 hp/200 hp
Material
Copper-free aluminum
Special features
Auxiliary contact (single block), external ground lug
SP3D Design Package - EID Explosionproof Compact Disconnect Switches
EID Series Explosionproof, Compact Disconnect Switches Brochure
EID Series Explosionproof, Compact Disconnect Switches catalog page
EID Explosionproof, Compact Disconnect Switches Canadian certification
EID Explosionproof, Compact Disconnect Switches Canadian certification
IF 1697 - EID 200A and 400A Disconnect
IF 1697 - EID 200A and 400A Disconnect
Eaton Specification Sheet - EIDC3200 S214 S784
Eaton Specification Sheet - EIDC3200 S214 S784
Feature: Copper-free aluminum enclosure provides corrosion resistance and lighter weight. Business Impact: easier handling on site, reduced structural support needs, and longer service life in harsh environments. Application: offshore platforms and chemical plants where exposure to corrosive agents is common. Feature: 200 A amperage rating with non-fused design enables safe isolation for large motors and simplifies the supply chain. Application: manufacturing lines with 15 to 200 HP motors requiring reliable, code-compliant disconnects. Feature: Auxiliary contact (single block) and external ground lug support remote signaling and safer grounding. Application: PLC integration, interlocking schemes, and safer maintenance in hazardous zones. Feature: Explosionproof, hazard-location capable enclosure with NEC/CEC and NEMA 4/7/9/3R ratings ensures compliance and protection across environments. Application: oil & gas, chemical processing, and mining installations. Feature: Dimensions and weight of 17.44 in depth, 29.44 in height, 13.19 in width, and 149 lb offer straightforward cabinet integration. Application: retrofit projects and new installations in space-constrained electrical rooms.
Get a Quick Quote for a Eaton Crouse-Hinds EIDC3200 S214 S784
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EIDC3200 S214 S784?
Enquire Now
FAQs
Installation in hazardous locations requires following the EID series installation guidance and applicable local codes. Use the external ground lug and the single-block auxiliary contact to support wiring, ensure enclosure integrity for Class I Zone 2 environments, and connect to 240-600 VAC circuits. Refer to IF 1697 instruction sheets for step-by-step mounting and wiring practices to maintain explosion-protection ratings.
Key specs include a 200 A amperage rating, 15/75/150/200 HP range, and operating voltage of 240-600 VAC with 250 VDC capability. It uses copper-free aluminum, is non-fused, features an auxiliary contact (single block), and includes an external ground lug for reliable grounding and control wiring in hazardous locations.
Yes. The EIDC3200 S214 S784 carries NEC/CEC compliance and hazardous-location ratings that cover Class I, Zone 2 and related classifications, along with suitable NEMA ratings (4, 7, 9, 3R) to meet protective enclosure requirements in challenging environments.
It's ideal for oil and gas, chemical processing, mining, and water-treatment facilities where safe motor isolation is required in hazardous locations. With a 200 A rating and HP range up to 200 HP, it supports medium-to-large motor control while maintaining robust enclosure protection and ease of maintenance.
Documentation includes installation sheets such as IF 1697, brochures, and catalogs, plus 3D design packages for EID Explosionproof Compact Disconnect Switches. You’ll also find datasheets and certification reports to assist with compliance, along with a catalog page that details components and accessory options like auxiliary contacts and ground lug fittings.