EIDC3200 S784 EID disconnect switch provides rugged, explosionproof isolation for hazardous locations. In demanding facilities, safe isolation, reliable performance, and regulatory compliance are constant challenges for engineers and maintenance teams. This unit carries NEC/CEC compliance and hazardous-location ratings including Class I Zone 1, Class I Division 2, Class I Zone 2, and Class II Division 1, with NEMA 4/3R/7/9 enclosures to support safe operation in harsh environments. Copper-free aluminum construction reduces weight while withstanding temperature and chemical exposure, and the auxiliary contact enables status signaling or interlocking with safety systems. Designed for explosionproof protection in oil, gas, chemical, and mining applications, it also supports efficient installation and ongoing maintenance within EID-series assemblies.

Product Information

Extended Description

EIDC3200 S784 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EID disconnect switch, 200A, With switch, Non-fused, 15 HP/75 HP/150 HP/200 HP, Copper-free aluminum, Auxiliary contact (single block), 240-600 Vac/250 Vdc
Product Name
Eaton Crouse-Hinds series EID disconnect switch
Catalog Number
EIDC3200 S784
Product Length/Depth
17.44 in
Product Height
29.44 in
Product Width
13.19 in
Product Weight
167 lb
UPC
662276474024
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2 Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
4 3 3R 7 9
Enclosure type
With switch
Fusing
Non-fused
Amperage Rating
200A
Horsepower
15 hp/75 hp/150 hp/200 hp
Material
Copper-free aluminum
Special features
Auxiliary contact (single block)
Feature: Explosionproof construction for hazardous locations → Business Impact: Enables compliant operation in Class I/II environments and reduces risk of ignition in oil, gas, and chemical plants → Application: Suitable for Class I Zone 1 and Zone 2 applications with NEC/CEC compliance and rugged enclosure ratings. Feature: 200A amperage rating with 15/75/150/200 HP options and dual voltage capability (240-600 Vac / 250 Vdc) → Business Impact: Supports a wide range of equipment and motor loads, lowering system integration costs and downtime → Application: Industrial power control in hazardous facilities. Feature: Non-fused design → Business Impact: Simplifies maintenance, reduces spare parts, and improves selective coordination for feeders and distribution panels → Application: Downstream switching in hazardous area distributions. Feature: Copper-free aluminum housing → Business Impact: Lighter enclosure with excellent corrosion resistance and durability under harsh conditions → Application: Outdoor or corrosive environments in mining and chemical plants. Feature: Auxiliary contact (single block) → Business Impact: Facilitates signaling and interlocking with safety systems, enabling safer start/stop sequences → Application: Control interlocks and remote status monitoring in hazardous installations. Feature: With-switch enclosure and compact footprint (17.44 in depth, 29.44 in height, 13.19 in width) → Business Impact: Easier field installation and integration with existing EID-series assemblies, reducing installation time and risk → Application: Retrofit projects and new builds in industrial facilities.

Get a Quick Quote for a Eaton Crouse-Hinds EIDC3200 S784

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EIDC3200 S784? Enquire Now

FAQs

EIDC3200 S784 is designed for EID-series assemblies and aligns with standard explosionproof enclosures used in Class I/II hazardous locations. Its dimensions and mounting footprint support straightforward retrofit or new-install projects, while the 17.44 in depth and 29.44 in height provide ample space for wiring, auxiliary contacts, and interlock accessories. Compatibility is enhanced by the non-fused design, which simplifies control schematics and reduces troubleshooting time.
This model provides a 200A amperage rating with horsepower options of 15/75/150/200 HP. It operates across a broad voltage window of 240-600 Vac and 250 Vdc, enabling flexible integration with motor starters and downstream protection devices in hazardous-area facilities. The non-fused configuration supports clean coordination with upstream protection and simplified diagnostics.
Yes. The unit carries NEC/CEC compliance with hazardous-location ratings including Class I Zone 1, Class I Division 2, and Class I Zone 2, along with Class II Division 1. It also aligns with NEMA ratings 4, 3, 3R, 7, and 9. These certifications support safe operation in oil, gas, chemical, and mining environments and assist with regulatory documentation and audits.
The auxiliary contact (single block) enables real-time status signaling and simple interlock integration with safety systems, reducing commissioning time and improving fault detection. In routine maintenance, you can verify switch status without opening the enclosure, which minimizes exposure to hazardous conditions and speeds up preventive maintenance tasks.
Non-fused designs reduce fault-related maintenance and spare-part requirements, while robust copper-free aluminum construction extends service life in harsh environments. Combined with reliable isolation control and NEC/CEC compliance, this translates to shorter downtime, safer operations, and predictable maintenance budgets in process-heavy industries like oil, gas, and chemical processing.