Eaton Crouse-Hinds EIDD3400 Disconnect Switch - Hazardous

Part Number: EIDD3400
Manufacturer
Eaton Crouse-Hinds
Part number
EIDD3400

Quick Summary

EIDD3400 disconnect switch from Eaton Crouse-Hinds provides safe, reliable isolation for industrial electrical systems. In hazardous locations, engineers often struggle to find a non-fused, rugged solution that withstands aggressive environments and regulatory scrutiny. This unit carries NEC/CEC compliance and hazard-area ratings, plus NEMA configurations 3, 3R, 4, 7, and 9 for versatile protection. By combining copper-free aluminum construction with a built-in switch and broad horsepower support, it streamlines panel design, reduces total cost of ownership, and improves uptime in oil and gas, chemical processing, mining, and other harsh-industrial applications. It also supports integration with standard protection equipment inventories while delivering install-time efficiency and long-term maintenance predictability.

Product Information

Extended Description

EIDD3400 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EID disconnect switch, 400A, With switch, Non-fused, 50 HP/125 HP/250 HP/350 HP, Copper-free aluminum, 240-600 Vac/250 Vdc
Product Name
Eaton Crouse-Hinds series EID disconnect switch
Catalog Number
EIDD3400
Product Length/Depth
17.19 in
Product Height
41.22 in
Product Width
13.49 in
Product Weight
258 lb
UPC
662276490598
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Zone 1 Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class III
NEMA Rating
3 3R 4 7 9
Enclosure type
With switch
Fusing
Non-fused
Amperage Rating
400A
Horsepower
50 hp/125 hp/250 hp/350 hp
Material
Copper-free aluminum
Feature: The EIDD3400 delivers a 400 A amperage rating with a horsepower range of 50/125/250/350, enabling it to isolate motors and loads across common industrial drives. This broad motor ratings profile translates to measurable business impact: fewer devices to stock, simpler protection coordination, and reduced installation time. The unit supports 240-600 Vac and 250 Vdc, making it suitable for a wide variety of plant feeders and MCCs in hazardous areas, including oil, gas, chemical processing, and mining facilities. It also supports energy-efficient motor control strategies by providing a single, compliant disconnect across multiple line voltages. This compatibility supports energy efficiency and streamlined procurement across multi-site facilities. | Feature: It comes non-fused and with a built-in switch, delivering a compact, ready-to-wire isolation point. The non-fused design reduces maintenance complexity and eliminates external fuses, decreasing spare parts inventory and downtime during replacement. In practice, technicians can rapidly disconnect power for lockout-tagout procedures and safe maintenance without swapping fuses or adding components. This integrated approach also simplifies panel layouts and improves fault isolation during commissioning. | Feature: Copper-free aluminum construction provides corrosion resistance and durability in harsh environments, while maintaining a robust enclosure for long service life. This material choice reduces overall weight relative to copper-bearing alternatives and improves heat dissipation in enclosed spaces. The enclosure’s rugged design withstands vibration, temperature swings, and chemical exposure common in hazardous locations, delivering lower maintenance costs over the life of the asset. | Feature: The EIDD3400 is an enclosure-with-switch option that aligns with standard installation practices, including 17.19 in depth, 41.22 in height, and 13.49 in width, supporting compatibility with existing switchgear footprints. NEMA ratings 3, 3R, 4, 7, 9 and NEC/CEC compliance ensure readiness for hazardous and classified locations across global markets. The availability of design resources—3D CAD packs, spec sheets, and installation instructions—streamlines design reviews, reduces commissioning time, and helps procurement lock in a reliable, standards-driven solution.

Get a Quick Quote for a Eaton Crouse-Hinds EIDD3400

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EIDD3400? Enquire Now

FAQs

The EIDD3400 is designed for Class I hazardous locations and classified areas, supporting NEC/CEC compliance with NEC ratings for Division and Zone classifications. It is suitable for oil and gas, chemical processing, mining, and other environments where rugged, code-compliant isolation is required.
It provides 400 A amperage with HP ratings of 50/125/250/350, operating from 240 to 600 Vac or 250 Vdc, and is non-fused with an integrated switch for straightforward isolation.
Yes. The unit is an enclosure-with-switch design with dimensions 17.19 in L x 41.22 in H x 13.49 in W and weighs 258 lb, making it compatible with common switchgear footprints and control panel layouts.
It carries NEC/CEC compliance and hazardous-location ratings, with NEMA 3, 3R, 4, 7, 9 protection, suitable for Class I Division 1/2 and Zone 1/2, as well as other hazardous environments.
With an integrated switch and non-fused design, maintenance is simplified, spare parts are reduced, and commissioning is faster. Access to CAD drawings, spec sheets, and installation instructions accelerates design reviews and project timelines, delivering a favorable total cost of ownership in harsh plants.