Eaton Crouse-Hinds EJB121206 S598 Junction Box - IP66

Part Number: EJB121206 S598
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EJB121206 S598

Quick Summary

EJB121206 S598 is a rugged junction box designed to protect electrical connections in hazardous locations. This enclosure helps prevent ingress, corrosion, and unplanned downtime in harsh environments where safety and reliability matter most. It carries NEC/CEC compliance and multiple hazardous-area ratings, including Class I, Division 1 and Zone 1, plus IP66 and a broad NEMA lineup (3, 3R, 4, 7, 9), ensuring suitability for demanding industrial settings. The copper-free aluminum construction delivers strong durability with lighter weight, while hinges mounted on the left side simplify service and maintenance. For engineers and procurement teams, this enclosure combines robust protection with straightforward installation and long-term lifecycle value, reducing risk and total cost of ownership.

Product Information

Extended Description

EJB121206 S598 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EJB junction box, 12" x 12" x 6", With hinge, Copper-free aluminum, Hinges mounted on left side, Style C
Product Name
Eaton Crouse-Hinds series EJB junction box
Catalog Number
EJB121206 S598
Product Length/Depth
17.06 in
Product Height
17.06 in
Product Width
8.88 in
Product Weight
95 lb
UPC
782274515595
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Zone 1 Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 3R 4 7 9
Ingress protection (IP) ratings
IP66
Enclosure size
12" x 12" x 6"
Style
C
Material
Copper-free aluminum
Hinge
With hinge
Special features
Hinges mounted on left side
Copper-free aluminum construction delivers rugged protection with reduced weight, boosting handling efficiency and installation safety in busy facilities. This material choice also lowers long-term corrosion-related maintenance costs in chemical, mining, and power environments. IP66, combined with NEMA ratings 3, 3R, 4, 7, 9 and NEC/CEC compliance, minimizes ingress risk and accelerates inspections, supporting faster permits and safer operation in oil, gas, and refinery settings. Left-side hinges and Style C design simplify service, inspection, and wiring termination, cutting maintenance time and improving field productivity. The 12" x 12" x 6" enclosure size provides ample internal volume for connectors and glands, reducing the need for multiple boxes and facilitating clean, compliant layouts. Copper-free aluminum also contributes to lower total cost of ownership through corrosion resistance and lighter handling, helping field crews assemble and upgrade enclosures more efficiently. In demanding environments where downtime is costly, this enclosure offers predictable performance and long service life with minimal risk.

Get a Quick Quote for a Eaton Crouse-Hinds EJB121206 S598

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EJB121206 S598? Enquire Now

FAQs

When installing the EJB121206 S598, plan for a left-side hinged cover to simplify access during maintenance. Mounting should follow the enclosure’s 12x12x6 footprint and use appropriate hardware compatible with copper-free aluminum. Ensure wiring terminations remain within the NEMA 3/3R/4/7/9 ratings and that the site complies with NEC/CEC and local hazardous-location requirements. The IP66 rating helps specify sealing needs for dust and water ingress, reducing rework after commissioning.
The enclosure carries Area classification for Hazardous/Classified Locations and NEC/CEC standards, with IP66 ingress protection and a NEMA rating lineup of 3, 3R, 4, 7, 9. These certifications indicate suitability for Class I/II/III environments, Zone 1/2 areas, and harsh industrial conditions, facilitating regulatory approvals, safety compliance, and installation in mining, oil & gas, and chemical processing facilities.
Yes. The enclosure is designed for hazardous locations and supports multiple hazardous-area ratings (Class I, Division 1/Zone 1, etc.), IP66 protection, and rugged copper-free aluminum construction. Its Style C design and left-hinged lid simplify field wiring and inspections, making it a practical choice for mining, oil/gas, and chemical processing where durability, safety, and regulatory compliance are critical.
Key standards to verify include NEC/CEC compliance for hazardous locations, IP66 for water and dust ingress protection, and the relevant NEMA ratings (3, 3R, 4, 7, 9). Also confirm the area classifications for Class I/II/III locations and Zone 1/2 applicability. In addition, Canadian and other regional certifications may be referenced in the catalog and UL reports.
Maintenance benefits arise from copper-free aluminum’s corrosion resistance and high ingress protection, which reduce repainting and corrosion-related servicing. The left-hinged Style C design speeds inspections and terminations, lowering labor costs. ROI improves through longer service life, fewer replacements, and easier upgrade paths in hazardous environments, while meeting stringent safety and compliance requirements.