Eaton Crouse-Hinds EJB181206 S598 Junction Box - IP66

Part Number: EJB181206 S598
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EJB181206 S598

Quick Summary

The Eaton Crouse-Hinds EJB181206 S598 junction box protects electrical terminations in hazardous locations. Installers face corrosion, moisture ingress, and tough maintenance in harsh environments, which can drive downtime and cost. It carries NEC/CEC compliance, UL certifications, and IP66 ingress protection, plus hazardous-location ratings like Class I, Zone 1 and Division 1, for broad market acceptance. Designed with copper-free aluminum and a left-side hinge, it delivers durable performance while simplifying field installation and service, making it an ideal explosionproof enclosure choice for demanding facilities. This enclosure supports efficient wiring layouts and compatible accessories, helping engineers meet project timelines and OPEX targets across multiple industries.

Product Information

Extended Description

EJB181206 S598 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EJB junction box, 18" x 12" x 6", With hinge, Copper-free aluminum, Hinges mounted on left side, Style C
Product Name
Eaton Crouse-Hinds series EJB junction box
Catalog Number
EJB181206 S598
Product Length/Depth
8.875 in
Product Height
17.31 in
Product Width
23.31 in
Product Weight
120 lb
UPC
782274438795
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 1 Class III Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class II, Division 2
NEMA Rating
9 3R 7 4 3
Ingress protection (IP) ratings
IP66
Enclosure size
18" x 12" x 6"
Style
C
Material
Copper-free aluminum
Hinge
With hinge
Special features
Hinges mounted on left side
Feature: IP66 ingress protection and durable NEMA compatibility. Business Impact: Provides reliable dust and water ingress resistance, reducing field failures and service calls in outdoor and harsh indoor environments. Application: chemical plants, wastewater treatment, and outdoor utility installations. Feature: Hazardous-location ratings with NEC/CEC compliance. Business Impact: Enables safe operation in Class I/Zone 1, Divisions 1 and 2, and Class II environments, ensuring regulatory adherence and smoother procurement. Application: oil & gas facilities, mining, and offshore platforms. Feature: Copper-free aluminum construction. Business Impact: Improves corrosion resistance while reducing weight and freight costs; lowers lifecycle maintenance and downtime. Application: remote installations and installations exposed to corrosive atmospheres. Feature: Left-side hinges with Style C configuration. Business Impact: Simplifies access for wiring terminations and routine maintenance, shortening service windows and improving uptime. Application: control rooms, process plants, and field-installed enclosures. Feature: Large interior footprint (18" x 12" x 6") with 120 lb weight rating. Business Impact: Accommodates complex terminations and cable routes, improving wiring efficiency and reducing panel fabrication time. Application: multi-cable terminations in hazardous locations and high-density control panels. Feature: UL certifications and broad NEMA ratings. Business Impact: Provides third-party validation for compliance across markets, accelerating project approvals. Application: regulated industries seeking proven safety and performance.

Get a Quick Quote for a Eaton Crouse-Hinds EJB181206 S598

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EJB181206 S598? Enquire Now

FAQs

This enclosure follows standard 18" x 12" x 6" footprint with Style C configuration and left-side hinges, making it compatible with common mounting patterns and accessories. Its copper-free aluminum body reduces weight without compromising strength, easing field installation and retrofits in hazardous locations.
Key specs include IP66 ingress protection, NEMA ratings (9, 3R, 7, 4, 3), and NEC/CEC compliance with Class I, Zone 1 and Division 1 classifications. UL certification support further validates safety, enabling compliant installations in oil & gas, chemical plants, and mining projects.
Yes. The enclosure is designed for hazardous locations with explosionproof characteristics and IP66 protection, suitable for chemical processing, oil & gas, mining, and other environments requiring robust exterior protection and regulatory compliance.
NEC/CEC compliance, UL certifications, and listed NEMA ratings streamline approval processes, reduce field rework, and support procurement across regulated industries. This minimizes certification risk and helps ensure installations meet mandatory safety standards.
Copper-free aluminum provides corrosion resistance, reducing replacement needs in harsh environments. Left-side hinges facilitate quicker access for inspections and terminations, lowering maintenance time and improving overall uptime for critical electrical infrastructure.