Eaton Crouse-Hinds EJB241810 Junction Box - IP66 Hazardous

Part Number: EJB241810
Manufacturer
Eaton Crouse-Hinds
Part number
EJB241810

Quick Summary

EJB241810 junction box from Eaton Crouse-Hinds protects critical control electronics in hazardous locations. Engineers often wrestle with ingress, corrosion, and regulatory hurdles when deploying equipment in Class I/II/III environments. This enclosure carries NEC/CEC certifications and lists Class I Division 1 and 2, Class II Division 1 and 2, Class III, plus IP66 and multiple NEMA ratings, ensuring code compliance across global sites. With a copper-free aluminum body and a 24 x 18 x 10 in footprint, it offers rugged protection and flexible mounting for heavy panels. Design teams gain faster installation and predictable lifecycle costs by choosing this explosion-proof junction box for hazardous locations, matching robust protection with practical, job-ready compliance.

Product Information

Extended Description

EJB241810 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EJB junction box, 24" x 18" x 10", Without hinge, Copper-free aluminum, Style C
Product Name
Eaton Crouse-Hinds series EJB junction box
Catalog Number
EJB241810
Product Length/Depth
14.25 in
Product Height
23.56 in
Product Width
29.625 in
Product Weight
273 lb
UPC
782274017761
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Zone 1 Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 3R 4 7 9
Ingress protection (IP) ratings
IP66
Enclosure size
24" x 18" x 10"
Style
C
Material
Copper-free aluminum
Hinge
Without hinge
Material and protective rating drive long-term reliability. The copper-free aluminum construction delivers excellent corrosion resistance in harsh environments, while IP66 and established NEMA ratings shield sensitive electronics from dust and water ingress. Business impact: reduced maintenance, fewer field repairs, and longer service intervals in chemical plants and outdoor installations. Application: use in outdoor substations and process areas where rugged protection is required. Size and design flexibility enable easier integration. The 24 x 18 x 10 inch footprint supports larger control assemblies, and the hinge-less Style C body simplifies sealing and inspection while reducing failure points. Business impact: faster commissioning, lower lifecycle costs, and dependable performance in demanding settings. Application: retrofits and new builds with heavy equipment enclosures. Certifications and compliance provide peace of mind. NEC/CEC conformity, Class I/II/III ratings, and IP66/NEMA 3,3R,4,7,9 ensure project-wide regulatory alignment. Business impact: streamlined procurement, consistent documentation, and global applicability. Application: multinational projects with varied standards. Engineering workflow compatibility boosts productivity. Access to CAD drawings and SP3D design packages reduces design time and minimizes errors. Business impact: accelerated delivery and improved project predictability. Application: engineering teams integrating enclosures into complex systems. Weight and handling considerations are essential. The model’s 273 lb weight necessitates proper lifting and anchoring during installation, reducing on-site surprises. Application: heavy-duty installations requiring reliable mounting solutions.

Get a Quick Quote for a Eaton Crouse-Hinds EJB241810

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EJB241810? Enquire Now

FAQs

EJB241810 is certified for NEC/CEC compliance with Class I Division 1 and 2 (as well as Class II and III), making it suitable for hazardous-location installations. Its IP66 and NEMA ratings further ensure protection against dust and water ingress, simplifying field acceptance across global sites.
The enclosure size is 24 x 18 x 10 inches, with general dimensions listed as 14.25 in length, 23.56 in height, and 29.625 in width in the spec set. The unit weighs 273 pounds, indicating a need for appropriate lifting and mounting equipment during installation.
The EJB241810 carries NEC/CEC certifications with Hazardous Location ratings including Class I Division 1 and 2, Class II Division 1 and 2, and Class III, plus protection levels IP66 and a range of NEMA ratings: 3, 3R, 4, 7, 9, ensuring compliance across multiple international standards.
Eaton provides downloadable CAD assets and SP3D design packages for the EJB241810, enabling accurate modeling, collision checks, and faster integration into electrical and process system layouts, which reduces design risk and project timelines.
Plan for heavy-duty mounting and lifting due to the 273 lb weight, ensure proper anchoring, maintain seal integrity for IP66 protection, and account for no hinge design which simplifies sealing but may affect access requirements during maintenance.