Eaton Crouse-Hinds EJB361810 Junction Box - IP66

Part Number: EJB361810
Manufacturer
Eaton Crouse-Hinds
Part number
EJB361810

Quick Summary

Eaton Crouse-Hinds EJB361810 junction box provides rugged, hazardous-location enclosure for cable terminations in industrial facilities. The challenge of deploying large, corrosion-resistant enclosures in harsh environments is often maintenance-heavy and behind schedule. It carries NEC and CEC compliance, IP sixty six ingress protection, and hazardous-location approvals such as Class I Division one and Zone one, with compatible NEMA ratings for versatile installation. With copper-free aluminum construction and a large thirty six by eighteen by ten inch footprint, it supports fast installation and long-term reliability. Designed for oil, gas, chemical, and general industrial automation applications, it helps ensure safety, regulatory alignment, and lower total cost of ownership.

Product Information

Extended Description

EJB361810 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EJB junction box, 36" x 18" x 10", Without hinge, Copper-free aluminum, Style C
Product Name
Eaton Crouse-Hinds series EJB junction box
Catalog Number
EJB361810
Product Length/Depth
41.9 in
Product Height
13.69 in
Product Width
23.9 in
Product Weight
396 lb
UPC
782274785448
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III Class I, Zone 1 Class I, Zone 2
NEMA Rating
3 3R 4 7 9
Ingress protection (IP) ratings
IP66
Enclosure size
36" x 18" x 10"
Style
C
Material
Copper-free aluminum
Hinge
Without hinge
Feature: copper-free aluminum construction. Business Impact: reduces corrosion, extending enclosure life in aggressive environments and lowering replacement costs. Application: chemical plants and offshore facilities where longevity matters. Feature: large enclosure footprint with 36 by 18 by 10 inch size. Business Impact: accommodates multiple terminations and future wiring expansions without rework. Application: control panel expansions in hazardous zones. Feature: Style C without hinge. Business Impact: simplifies sealing, lowers maintenance, and speeds retrofit projects. Application: retrofit or new builds where dependable gasket integrity is essential. Feature: IP sixty six ingress protection. Business Impact: minimizes dust and water ingress, reducing field service interruptions. Application: outdoor or damp indoor locations with demanding exposure. Feature: NEC/CEC compliance and hazardous-location approvals. Business Impact: streamlines compliance workflows and accelerates regulatory approvals. Application: installation in Class I and Zone one environments across energy, chemical, and processing sectors. Feature: NEMA ratings three, three R, four, seven, nine. Business Impact: supports diverse equipment protection needs across varied installation scenarios. Application: combination of indoor and outdoor installations requiring versatile protection classes. Feature: thirty six by eighteen by ten inch enclosure size with copper-free aluminum and IP66 rating. Business Impact: combines robust protection with manageable handling for larger systems. Application: industrial control cabinets where space and performance matter. Feature: 3D CAD drawing package and installation guidance in downloads. Business Impact: reduces engineering time, minimizes field modifications, and accelerates commissioning. Application: project design and on-site assembly for expedited deployment.

Get a Quick Quote for a Eaton Crouse-Hinds EJB361810

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EJB361810? Enquire Now

FAQs

Yes, the EJB361810 is designed for hazardous locations and carries NEC/CEC compliance with protections suitable for Class I Division one and Zone one environments, along with IP sixty six ingress protection for rugged outdoor and challenging indoor conditions.
The enclosure is copper-free aluminum, Style C, without hinge, and sized at thirty six by eighteen by ten inches. It carries an IP sixty six rating and a UPC for tracking, with a weight suitable for robust industrial use and a construction designed to withstand demanding environments.
It supports NEC and CEC standards, hazardous-location approvals including Division one and Zone one classifications, and compatible NEMA ratings such as three, three R, four, seven, and nine, enabling safe operation in oil, gas, and chemical facilities.
Plan for a proper sealing interface with copper-free aluminum, use appropriate mounting hardware for hazardous locations, reference the installation sheets, and leverage the provided CAD drawings to minimize field modifications and ensure a code-compliant, reliable setup.
Choosing this enclosure improves reliability in harsh environments, reduces maintenance intervals, accelerates project timelines with ready-made drawings and documentation, and supports regulatory compliance, delivering a lower total cost of ownership for hazardous-location electrical infrastructure.