Eaton EKC80 Condulet Outlet Body - Hazardous Locations

Part Number: EKC80
Manufacturer
Eaton Crouse-Hinds
Part number
EKC80

Quick Summary

EKC80 Condulet outlet body is an explosion-proof conduit enclosure designed for rugged terminations in hazardous locations. In industrial facilities, inconsistent protection and undersized enclosures drive maintenance delays and safety risks. The unit carries NEC/CEC compliance and area classifications for Hazardous/Classified Locations, with NEMA ratings 7 and 9, providing reliable performance in demanding environments. Built from Feraloy iron alloy and sized for a 3 inch trade conduit, it offers ample internal space and durability for long-term service. By standardizing on this EKC80, engineers simplify procurement and maintenance planning while protecting critical instrumentation and power feeds.

Product Information

Extended Description

EKC80 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet EKC conduit outlet body with cover, Feraloy iron alloy, 3"
Product Name
Eaton Crouse-Hinds series Condulet EKC conduit outlet body with cover
Catalog Number
EKC80
Product Length/Depth
21.75 in
Product Height
6.63 in
Product Width
6 in
Product Weight
43.2 lb
UPC
782274744674
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
7 9
Trade size
3"
Material
Feraloy iron alloy
Feature: Explosion-proof EKC80 Condulet body provides rugged protection for conduit terminations in hazardous locations. Business Impact: This durability reduces maintenance intervals and protects critical power and control circuits in process plants. Application: Use in chemical, oil and gas, and mining facilities where safety and reliability matter. Feature: 3 inch trade size with a 21.75 inch length and generous internal volume. Business Impact: Simplifies wiring routing and minimizes field splices, cutting installation time and error. Application: Ideal for large motor feeders and control circuits in space-constrained enclosures across manufacturing lines. Feature: Feraloy iron alloy construction. Business Impact: Provides high strength and corrosion resistance for outdoor and harsh chemical environments, extending service life and reducing replacement costs. Application: Suitable for outdoor process skids, chemical plants, and mining equipment enclosures. Feature: NEC/CEC compliance, area classifications, and NEMA ratings 7 and 9. Business Impact: Ensures regulatory compliance, improves audit readiness, and supports UL certification pathways. Application: Required for facilities in hazardous locations needing reliable explosion-proof protection for splices and terminations. Feature: OE/EKC Condulet compatibility and catalog availability. Business Impact: Enables standardization across sites, easier procurement, and fast integration with existing conduit fittings. Application: Retrofit projects and new builds using 3 inch conduit systems.

Get a Quick Quote for a Eaton Crouse-Hinds EKC80

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EKC80? Enquire Now

FAQs

Follow Eaton's installation guidelines as outlined in the EKC80 specification sheet. Use appropriate gaskets and seals, mount per the chassis dimensions, connect conductors to the internal terminations, and ensure proper grounding and enclosure sealing. The 3" trade size supports substantial conductor routing, and the assembly is designed for reliable performance in Class I/II/III hazardous locations per NEC/CEC.
EKC80 carries NEC/CEC compliance for hazardous locations and supports area classifications for Hazardous/Classified Locations. It is rated under NEMA 7 and 9 and is designed for Class I Division 1 and 2, Class II Division 1 and 2, and Class III environments. UL certification documentation is available, ensuring regulatory assurance for industrial installations.
Yes. EKC80 is engineered for hazardous locations and is compatible with Class I Division 1 and 2 environments. Its explosion-proof construction and 3" trade-size conformance ensure safe splices and terminations in demanding facilities such as chemical plants and oil refineries, while meeting NEC/CEC standards and NEMA 7/9 ratings.
The EKC80 features a 3 inch trade size with overall dimensions of 21.75 inches in length, 6.63 inches in height, and 6 inches in width, and it weighs 43.2 pounds. These dimensions provide substantial internal volume for wiring while maintaining a compact footprint suitable for rugged industrial installations.
EKC80 delivers long-term value by combining explosion-proof protection with robust Feraloy iron alloy construction, reducing maintenance and replacement costs in hazardous environments. Its NEC/CEC compliance and NEMA ratings simplify audits, while standard 3" conduit compatibility and OE/EKC family integration streamline procurement, installation, and spares management across multiple sites.