Eaton Crouse-Hinds ENR12202 M4 - Explosionproof Receptacle

Part Number: ENR12202 M4
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
ENR12202 M4

Quick Summary

Eaton Crouse-Hinds ENR Premier receptacle assembly provides safe, reliable power in hazardous-area installations. End users often face downtime and non-compliant enclosures when selecting equipment for demanding environments, which drives maintenance costs and safety risk. This receptacle line carries NEC/CEC compliance, Hazardous/Classified Locations area classification, and a robust NEMA rating of 3, 3R, 7, 9, 12 to support reliable operation in harsh conditions. By pairing a copper-free aluminum body with a compact two-gang footprint, ENR12202 M4 delivers easy installation, long-term corrosion resistance, and consistent plug performance. For facilities pursuing safer, regulated power distribution, it also enables streamlined procurement workflows and standardized equipment across multi-site operations.

Product Information

Extended Description

ENR12202 M4 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ark-Gard ENR Premier receptacle assembly, 20A, Double, 50-400 Hz, Copper-free aluminum, 6-20R, Two-gang, Dead end, 1/2", 250 Vac
Product Name
Eaton Crouse-Hinds series Ark-Gard ENR Premier receptacle assembly
Catalog Number
ENR12202 M4
Product Length/Depth
6.78 in
Product Height
6.75 in
Product Width
7.56 in
Product Weight
0.999 lb
UPC
662276174368
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 3R 7 9 12
Number of gangs
Two-gang
Amperage Rating
20A
Voltage rating
250 Vac
Style
Dead end
Trade size
1/2"
NEMA configuration
6-20R
Cover type
Double
Material
Copper-free aluminum
Frequency rating
50-400 Hz
Feature: Amperage Rating is 20A at 250 Vac. Business Impact: Supports common motor loads and lighting circuits in hazardous areas without oversizing equipment, reducing upfront cost and heat generation. Application: Two-gang ENR Premier receptacle in demanding installations where space and compliance matter. Feature: Copper-free aluminum construction. Business Impact: Delivers lightweight, corrosion-resistant hardware that lowers maintenance costs and extends service life in corrosive environments. Application: Outdoor or marine-rated hazardous locations where metal compatibility matters. Feature: NEMA configuration 6-20R with Double cover. Business Impact: Ensures secure, weather-resistant connections and predictable mating with locking devices, reducing mis-wiring risk and downtime. Application: Industrial plants with frequent plug/unplug cycles and demanding enclosures. Feature: Frequency rating 50-400 Hz. Business Impact: Supports global equipment fleets and variable-speed drives without reconfiguration, improving cross-site deployment efficiency. Application: Multi-region automation installations and power distribution networks. Feature: Trade size 1/2" and two-gang Dead end style. Business Impact: Simplifies conduit entry and wiring density, enabling faster field terminations and cleaner panel layouts. Application: Compact control cabinets and hazardous-area motor circuits. Feature: Area classification Hazardous/Classified Locations with NEC/CEC compliance and NEMA ratings. Business Impact: Provides proven safety and regulatory alignment, reducing risk of non-compliance penalties and rework. Application: Refineries, chemical plants, offshore platforms, and other high-risk facilities. Insight: Installation compatibility with Ark-Gard ENR Premier devices and related accessories supports faster sourcing, standardized training, and consistent lifecycle management across facilities. This makes ENR12202 M4 a practical choice for project teams targeting reliability, safety, and total cost of ownership.

Get a Quick Quote for a Eaton Crouse-Hinds ENR12202 M4

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds ENR12202 M4? Enquire Now

FAQs

ENR12202 M4 uses a 6-20R NEMA configuration in a two-gang, dead-end assembly rated for 250 VAC and 20 A. The copper-free aluminum body provides corrosion resistance, while the double cover offers protection against dust and moisture intrusion. This combination supports reliable, lockable connections in hazardous areas and simplifies spare-parts planning for maintenance teams.
The ENR12202 M4 is designed to meet NEC/CEC standards for hazardous locations and is rated for Hazardous/Classified Locations. It carries a NEMA rating set (3, 3R, 7, 9, 12) to ensure appropriate enclosure protection. These certifications help ensure regulatory compliance, safer operation, and consistent performance across industrial environments, reducing regulatory risk and enabling easier audits.
Yes. ENR12202 M4 is specified for Class I, Division 1 and Division 2, Class II, Division 1 and 2, Class III environments, aligning with NEC hazardous-location requirements. Its explosionproof construction and Ark-Gard ENR Premier design mitigate ignition risks, supporting compliant installation in equipment rooms, process areas, and offshore platforms where flammable atmospheres may be present.
Plan for a copper-free aluminum housing with a 1/2" trade size and a two-gang footprint to fit standard enclosures. Verify that the conduit entries and wiring methods meet local codes, ensure correct lockout/tagout practices, and use compatible Ark-Gard ENR covers when performing maintenance or replacement. The product’s weight around 1 lb aids handling in confined spaces.
The aluminum construction reduces corrosion-related maintenance and weight, contributing to lower lifecycle costs. The robust NEC/CEC compliance and NEMA protection lessen the likelihood of non-conformance penalties and unplanned downtime. Over multiple sites, standardized ENR Premier receptacles simplify training, spares management, and future upgrades, delivering a favorable total cost of ownership.