Eaton Crouse-Hinds ENR22201 S752 Receptacle - NEC/CEC
Part Number: ENR22201 S752
Manufacturer
Eaton Crouse-Hinds
Part number
ENR22201 S752
Category
Quick Summary
Ark-Gard ENR Value receptacle assembly provides rugged, code-compliant power connections for hazardous-area equipment. In demanding plants, corrosion, dirt, and vibration threaten uptime and inflate maintenance costs unless you employ proven, durable hardware. It carries NEC/CEC hazardous-location ratings with Class I, II, III divisions and a NEMA 12 enclosure, backed by a corrosion-free epoxy powder finish to withstand harsh environments. This design supports a two-gang, dead-end configuration with a 125 VAC, 20 A rating and a broad 50–400 Hz range, aligning with diverse industrial loads. For OEMs and service teams, it offers predictable performance, fast installation, and long-term cost efficiency in hazardous locations.
Product Information
Extended Description
ENR22201 S752 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ark-Gard ENR Value receptacle assembly, 20A, Double, 50-400 Hz, Copper-free aluminum, 5-20R, Two-gang, Dead end, 3/4", 125 Vac, Corro-free epoxy powder finish
Product Name
Eaton Crouse-Hinds series Ark-Gard ENR Value receptacle assembly
Catalog Number
ENR22201 S752
Product Length/Depth
7.56 in
Product Height
6.72 in
Product Width
8 in
Product Weight
13.4 lb
UPC
782274787367
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class III Class II, Division 2
NEMA Rating
12 9 3 7
Number of gangs
Two-gang
Amperage Rating
20A
Voltage rating
125 Vac
Style
Dead end
Trade size
3/4"
NEMA configuration
5-20R
Cover type
Double
Material
Copper-free aluminum
Frequency rating
50-400 Hz
Special features
Corro-free epoxy powder finish
Ark-Gard ENR Value Explosionproof NEMA Locking Devices catalog page
Ark-Gard ENP, ENR, ENC Explosionproof NEMA Locking Devices Canadian certification - ENR and ENP
Ark-Gard ENP, ENR, ENC Explosionproof NEMA Locking Devices Canadian certification - ENR and ENP
IF 344 - Ark-Gard ENR Receptacles ENP Model M97 Plugs
IF 344 - Ark-Gard ENR Receptacles ENP Model M97 Plugs
Eaton Specification Sheet - ENR22201 S752
20A 125 VAC with a 50–400 Hz range provides broad compatibility across motors, drives, and control panels, reducing part variety and stocking costs while simplifying wiring in hazardous areas. This translates to shorter project timelines and lower lifecycle costs as equipment upgrades occur. Copper-free aluminum construction delivers corrosion resistance and lighter weight, easing installation and reducing mounting stress in vibration-prone environments, particularly in offshore and chemical facilities where copper-containing components pose challenges. The corro-free epoxy powder finish guards against moisture, chemicals, and abrasion, extending service life and minimizing touch-up maintenance after inspections. The two-gang, dead-end configuration with a 3/4" trade size and double cover ensures a compact, field-ready footprint, compatible with standard enclosures and simplifying retrofits in existing plants. NEC/CEC compliance plus Class I, II, III hazard-location ratings and NEMA 12 protection provide regulatory confidence, reducing approval time and risk during audits, while delivering safer, easier maintenance in demanding installations. These features collectively support faster installations, lower repair costs, and sustained reliability for industrial electrical systems.
Get a Quick Quote for a Eaton Crouse-Hinds ENR22201 S752
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds ENR22201 S752?
Enquire Now
FAQs
The ENR22201 S752 uses a two-gang, NEMA 5-20R configuration at 125 VAC and 20 A, with a 3/4 inch trade size. Its design aligns with common hazardous-location panels and standard plugs, reducing the need for specialized adapters and simplifying retrofits in Class I, II, and III environments.
This receptacle assembly is rated for NEC/CEC hazardous locations with Class I, Division 1 and 2, Class II Division 1 and 2, and Class III. Combined with a NEMA 12 enclosure, it provides robust protection against dust, water ingress, and chemical exposure, streamlining regulatory approvals and audits.
Yes. The ENR22201 S752 is designed for compatibility with Ark-Gard ENR Value devices and standard two-gang enclosures, enabling straightforward retrofits without significant panel modification. The 3/4" trade size and 5-20R configuration support efficient integration with existing power distribution layouts.
Consider mounting in vibration-prone or damp locations using the copper-free aluminum housing and corrosion-free epoxy finish to minimize wear. Ensure proper gromming and sealing per installation sheets, and verify that the area classification aligns with Class I, II, III definitions to maintain compliance.
Ark-Gard ENR Value combines durable materials, corrosion resistance, and NEC/CEC compliance with a practical two-gang, dead-end form factor. The result is faster installations, longer service life, lower maintenance costs, and improved uptime for critical equipment in hazardous locations.