ENRX21202 S752 Ark-Gard receptacle assembly delivers rugged power connectivity for hazardous-area equipment. In harsh environments, downtime and safety compliance gaps can cost you time and money. This unit carries Hazardous/Classified Locations approvals, NEC/CEC compliance, and IP66/NEMA 4X protection for reliable operation. Copper-free aluminum with an external epoxy coating reduces corrosion risks, while a 3/4 inch trade size and 6-20R configuration simplify field wiring and panel integration. Designed for single-gang installations in 50-400 Hz systems, it helps you meet industry standards without sacrificing performance. This translates to lower maintenance costs and faster commissioning for hazardous-location projects.

Product Information

Extended Description

ENRX21202 S752 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ark-Gard ENRX receptacle assembly, 20A, Single cover, 50-400 Hz, Copper-free aluminum, 6-20R, Single-gang, External epoxy coating, Dead end, 3/4", 250 Vac
Product Name
Eaton Crouse-Hinds series Ark-Gard ENRX receptacle assembly
Catalog Number
ENRX21202 S752
Product Length/Depth
7.5 in
Product Height
6.97 in
Product Width
3.5 in
Product Weight
4.4 lb
UPC
662277119412
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Number of gangs
Single-gang
Amperage Rating
20A
Voltage rating
250 Vac
Style
Dead end
Trade size
3/4"
NEMA configuration
6-20R
Cover type
Single
Material
Copper-free aluminum
Frequency rating
50-400 Hz
Special features
External epoxy coating
The ENRX21202 S752 Receptacle Assembly is built to meet Class I, Division 2 and Zone 2 requirements while delivering IP66 and NEMA 4X protection. This combination reduces the risk of ignition sources and water ingress, enabling safe operation in explosive atmospheres. You gain regulatory confidence during audits and avoid costly redesigns when process conditions change. A 20A, 250 VAC rating and a 6-20R NEMA configuration provide straightforward compatibility with common industrial equipment. The 3/4 inch trade size simplifies conduit and cable entry, while the single-gang footprint saves panel space and minimizes installation time. The copper-free aluminum construction with external epoxy coating improves corrosion resistance in chemical, marine, and dusty environments. With a frequency rating of 50-400 Hz, the ENRX21202 supports mixed-power environments without derating. Its external epoxy coating and rugged enclosure guard against abrasion and chemical exposure, reducing maintenance intervals. In addition, the single cover design eases field service and replacement, helping maintenance teams accelerate outages and shorten downtime. Ark-Gard ENRX devices are widely adopted in oil and gas, mining, and shipboard applications due to reliable sealing and modular configuration. Field-installers appreciate the clear NEMA/IEC alignment, while procurement benefits from a standardized solution across sites.

Get a Quick Quote for a Eaton Crouse-Hinds ENRX21202 S752

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds ENRX21202 S752? Enquire Now

FAQs

For Zone 2 installations, ensure the receptacle is mounted in a single-gang enclosure with appropriate sealing and a compatible cover. Use 3/4" tradesize wiring entries and route conductors through a suitable conduit system. The IP66/NEMA 4X construction supports exposure to dust, water jets, and corrosive elements, reducing ingress risk during maintenance.
The unit is rated 20A at 250 VAC with a frequency range of 50-400 Hz and a 6-20R NEMA configuration. It uses copper-free aluminum housing with external epoxy coating for corrosion resistance and features IP66 protection plus NEMA 4X sealing for harsh environments.
Yes. ENRX21202 S752 is designed for Hazardous/Classified Locations, meeting Class I Division 2 and Zone 2 requirements. It provides robust protection against moisture, dust, and ignition risks, enabling safe operation for equipment like pumps, motors, and control panels in hazardous areas.
The receptacle supports NEC/CEC standards, Hazardous/Classified Locations classifications, IP66 ingress protection, and NEMA 4X enclosure rating. It is designed for external epoxy-coated copper-free aluminum construction to withstand challenging industrial and marine conditions.
Longer service life is driven by corrosion-resistant materials and an external epoxy coating, reducing replacement intervals. The single-gang, compact footprint simplifies installation and future upgrades, lowering commissioning time and maintenance labor. Overall, this translates to lower downtime, simpler audits, and a favorable total cost of ownership for hazardous-location projects.