Eaton Crouse-Hinds EPCS2217A Snap Switch - IP66
Part Number: EPCS2217A
Manufacturer
Eaton Crouse-Hinds
Part number
EPCS2217A
Quick Summary
EPCS2217A is a rugged snap switch for hazardous locations, delivering reliable control in industrial environments. Many engineers struggle with equipment that must survive dust, water, and explosive atmospheres while keeping installation straightforward. This unit meets NEC/CEC standards and IP66 protection, with hazardous location classifications for Class I and II environments. Its copper-free aluminum body and 1/2" NPT entry help reduce weight, simplify wiring, and lower lifecycle costs. This translates to safer startup, easier compliance audits, and predictable maintenance cycles for plants operating in remote or offshore sites. Designed for surface mounting and single-gang installations, it streamlines retrofits and new builds alike.
Product Information
Extended Description
EPCS2217A Eaton Crouse-Hinds: Eaton Crouse-Hinds series Pauluhn EPCS snap switch, 20A, Single-pole, With switch, 1/2" NPT entry, Copper-free aluminum, Single-gang, Surface mount, Dead end, Double-throw (ON/OFF/ON), 120-277 Vac
Product Name
Eaton Crouse-Hinds series Pauluhn EPCS snap switch
Catalog Number
EPCS2217A
Product Length/Depth
3.75 in
Product Height
6.38 in
Product Width
4.88 in
Product Weight
4.5 lb
UPC
662276391413
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2
Ingress protection (IP) ratings
IP66
Enclosure type
With switch
Type
Double-throw (ON/OFF/ON)
Amperage Rating
20A
Voltage rating
120-277 Vac
Number of gangs
Single-gang
Style
Dead end
Entry size
1/2" NPT
Material
Copper-free aluminum
Special features
Surface mount
Pauluhn EPCS Explosionproof Marine Snap Switch catalog page
IF LBL 1500 - EPCS221 Locking Switch
Eaton Specification Sheet - EPCS2217A
Copper-free aluminum construction provides robust corrosion resistance while keeping weight low, supporting easier handling during installation and service in marine and chemical environments. This material choice reduces refurbishment frequency and total cost of ownership in offshore platforms and processing facilities, where salt spray and chemicals accelerate wear. The EPCS2217A is well suited for retrofit projects in single-gang enclosures, and its copper-free body helps meet environmental sustainability goals. For technicians, the combination of strength and lighter weight translates to faster commissioning and safer handling in confined spaces. IP66 protection guards against dust ingress and powerful water exposure, minimizing nuisance trips and unplanned downtime in rugged sites such as offshore rigs and chemical plants. The enclosure design works in tandem with the snap switch mechanism to maintain reliable operation even when routine washdowns occur. Combined with NEC/CEC compliance and hazardous-location classifications (Class I and II), it simplifies regulatory documentation and inspection readiness for plant upgrades and new builds. With a 20A amperage rating and 120–277 VAC voltage range, the EPCS2217A supports typical control circuits for motors, fans, and process equipment across industrial automation architectures. The double-throw ON/OFF/ON configuration enables safe in-line switching and easy isolation for maintenance without removing power to the entire panel. Built for surface-mount installation and dead-end wiring, this unit also accommodates diverse wiring schemes and simplifies accessories selection. Compact footprint with single-gang, surface-mount design and 1/2" NPT entry streamlines wiring, conduit connections, and field wiring layouts. It reduces panel depth requirements and speeds up retrofits in existing installations, while the surface-mount option improves accessibility for inspection and testing in hazardous areas. The combination of small size and robust enclosure helps align with best practices for explosion-protected control devices. Industry-grade certifications and marine-rated construction support consistent performance in hazardous/classified locations, enabling dependable operation under challenging temperature and vibration conditions. The device aligns with NEC/CEC requirements, supports compliance programs, and contributes to safer start-up, ongoing maintenance, and predictable ROI for capital projects in oil, gas, mining, and chemical sectors.
Get a Quick Quote for a Eaton Crouse-Hinds EPCS2217A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EPCS2217A?
Enquire Now
FAQs
Install the EPCS2217A in a single-gang, surface-mount enclosure with 1/2" NPT conduit entry. Ensure it is used in accordance with NEC/CEC guidelines and the device’s hazardous-location classifications (Class I, II; Divisions 1 and 2). Use the provided installation instructions (IF LBL 1500) for locking switch configurations and proper mounting torque to maintain IP66 integrity and safe operation.
The EPCS2217A supports 20A at 120–277 VAC in a double-throw (ON/OFF/ON) configuration. It is a single-pole unit with a 1/2" NPT entry and copper-free aluminum housing, designed for surface mounting and dead-end wiring in hazardous locations. Its IP66 rating ensures protection against dust and powerful water jets during routine maintenance.
Yes. The EPCS2217A is designed for hazardous and classified locations with IP66 ingress protection and a copper-free aluminum body, making it well-suited for marine and offshore environments where corrosion resistance and rugged construction are essential for reliable operation.
The unit carries NEC/CEC standards compliance and hazardous-location classifications (Class I, Division 1 and 2; Class II, Division 1 and 2). It is intended for use in Hazardous/Classified Locations, with IP66 protection to withstand demanding industrial conditions and washdown protocols.
The copper-free aluminum construction and sealed IP66 enclosure reduce corrosion-related maintenance and downtime, while straightforward wiring and a compact single-gang footprint speed commissioning. These factors contribute to lower lifecycle costs and a faster return on investment for capital projects in oil, gas, mining, and chemical sectors.