Eaton Crouse-Hinds EYS6 SA Conduit Sealing Fitting - Hazardous Locations

Part Number: EYS6 SA
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EYS6 SA

Quick Summary

The EYS6 SA conduit sealing fitting is a rugged sealing solution for hazardous-location enclosures in industrial plants. Engineers often struggle with maintaining seal integrity under vibration, limited space, and complex installation sequences. This product carries NEC/CEC certifications and explicit Hazardous/Classified Locations ratings including Class I Division 1 and 2, Class II Division 1 and 2, and Class III, providing confidence across upstream and downstream operations. Vertical or horizontal sealing flexibility supports precise fit in tight conduits and variable orientations. By combining lightweight copper-free aluminum with robust sealing, it helps reduce weight, downtime, and total cost of ownership while enabling compliant, proactive maintenance practices.

Product Information

Extended Description

EYS6 SA Eaton Crouse-Hinds: Eaton Crouse-Hinds series EYS conduit sealing fitting, Female, Copper-free aluminum, Vertical or horizontal, 2"
Product Name
Eaton Crouse-Hinds series EYS conduit sealing fitting
Catalog Number
EYS6 SA
Product Length/Depth
5.2 in
Product Height
3.6 in
Product Width
9.3 in
Product Weight
1.95 lb
UPC
782274275772
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
Sealing position
Vertical or horizontal
Gender
Female
Trade size
2"
Material
Copper-free aluminum
Feature: Sealing position offers vertical or horizontal orientation. Business Impact: installation flexibility reduces field rework and inventory complexity. Application: ideal for control panels and enclosures in constrained spaces where seal alignment matters.\n\nFeature: Copper-free aluminum construction. Business Impact: delivers lighter weight with strong corrosion resistance, improving ease of handling and long-term durability in harsh environments. Application: suits oil & gas, mining, and chemical processing facilities exposed to aggressive atmospheres.\n\nFeature: NEC/CEC compliance with hazardous-location ratings. Business Impact: accelerates approvals, minimizes risk, and supports regulatory-driven projects. Application: mandatory for projects in Hazardous/Classified Locations across North America.\n\nFeature: 2 inch trade size and female gender. Business Impact: streamlines procurement and compatibility with standard conduit systems, reducing field adaptation time. Application: retrofit and new-build installations in industrial facilities.\n\nFeature: Vertical or horizontal sealing capability plus certified installation guidance (IF 287). Business Impact: faster commissioning, fewer install errors, and consistent performance. Application: field teams deploying across multiple zones and orientations.

Get a Quick Quote for a Eaton Crouse-Hinds EYS6 SA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EYS6 SA? Enquire Now

FAQs

For proper installation, follow the IF 287 conduit sealing instructions and ensure the sealing orientation matches the enclosure layout. Verify the 2" trade size, female configuration, and copper-free aluminum construction are compatible with your conduit system. Use appropriate gaskets and tighten per manufacturer guidance to prevent leaks in hazardous locations. Field teams should plan orientation in advance to minimize rework in tight spaces.
Key specifications include 2" trade size, female gender, copper-free aluminum material, sealing position vertical or horizontal, and a datasheet-confirmed length of 5.2 in, height of 3.6 in, and width of 9.3 in. It weighs 1.95 lb and is UPC 782274275772. It is designed for NEC/CEC compliance with Class I, Division 1 & 2, Class II Division 1 & 2, and Class III ratings for hazardous locations.
Yes. The EYS6 SA is certified for Hazardous/Classified Locations under NEC/CEC standards, including Class I Division 1 & 2, Class II Division 1 & 2, and Class III. This makes it appropriate for electrical enclosures in oil and gas, chemical processing, mining, and other environments where hazardous atmospheres require explosion-protected sealing.
The EYS6 SA carries NEC/CEC standards with explicit hazardous-location ratings (Class I, Division 1 & 2; Class II, Division 1 & 2; Class III) and area classification of Hazardous/Classified Locations. This compliance supports code approvals, project qualification, and safer operation in regulated industries, including cross-border projects that necessitate Canadian certifications as referenced in product documentation.
Installing the EYS6 SA delivers measurable ROI through enhanced seal integrity, reduced field rework due to orientation flexibility, and faster commissioning thanks to notes and installation guidance. Its lighter copper-free aluminum construction improves handling, while certified hazardous-location ratings reduce compliance risk and potential downtime in critical process areas.