Eaton Crouse-Hinds FMVA15LCY-UNV1-76-M25 LED Floodlight - IP66
Part Number: FMVA15LCY-UNV1-76-M25
Manufacturer
Eaton Crouse-Hinds
Part number
FMVA15LCY-UNV1-76-M25
Category
Quick Summary
FMVA LED floodlight from Eaton Crouse-Hinds delivers high-output area illumination for hazardous locations. In challenging environments, operators face inconsistent brightness, lens damage, and maintenance costs that disrupt productivity. It carries IECEx/ATEX certifications, NEC/CEC compliance, IP66 ingress protection, and a rugged NEMA 4X housing to meet global safety requirements. The dimmable driver, wide voltage range, and efficient 15,000-lumen performance help plants reduce energy use, downtime, and total cost of ownership. Designed for oil refineries, chemical plants, offshore facilities, and outdoor yards, the FMVA's robust build minimizes replacement cycles while keeping operators well-lit. By aligning with DLC references and offering easy integration with existing power systems, it supports safer, more resilient facilities.
Product Information
Extended Description
FMVA15LCY-UNV1-76-M25 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Champ FMVA LED floodlight, Cool white, Dimmable driver, 25mm entry, 500W equiv, Heat and impact resistant glass lens, 15000 lumens, 140 lm/W, Die cast alum, Yoke mount, 100-277 Vac, 108-250 Vdc, 113W, 7x6 optics
Product Name
Eaton Crouse-Hinds series Champ FMVA LED floodlight
Catalog Number
FMVA15LCY-UNV1-76-M25
Product Length/Depth
15.5 in
Product Height
12 in
Product Width
7 in
Product Weight
31.8 lb
UPC
662276885004
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC IECEx/ATEX
NEC hazardous rating
Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class III
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lamp type
LED
Lumens
15000
Lumens per watt
140
Color temperature
Cool white
Mounting Method
Yoke
Voltage rating
100-277 Vac, 108-250 Vdc
Frequency rating
50/60 Hz
Optical distribution
7x6
Entry size
25 mm
Lens material
Heat and impact resistant glass
Wattage
113W
Dimming
Dimmable driver
Equivalent luminaire
500W
Power factor
> 0.90
Material
Die cast aluminum
SP3D Design Package - Champ FMVA LED Hazardous Area Floodlights
Crouse-Hinds series DLC approved lighting products
Crouse-Hinds series DLC approved lighting products
Crouse-Hinds series Champ FMVA LED Floodlights - 9,000 to 15,000 lumens catalog page
Champ FMVA LED Hazardous Area Floodlights IECEx Certificate of Conformity
Champ FMVA LED Hazardous Area Floodlights IECEx Certificate of Conformity
Champ FMVA LED Hazardous Area Floodlights IECEx Certificate of Conformity
Champ FMVA LED Hazardous Area Floodlights IECEx Certificate of Conformity
Champ FMVA LED Hazardous Area Floodlights IECEx Certificate of Conformity
Champ FMVA LED Hazardous Area Floodlights IECEx Certificate of Conformity
IF 1883 - Champ FMVA LED Floodlight
IF 1883 - Champ FMVA LED Floodlight
Eaton Specification Sheet - FMVA15LCY-UNV1-76-M25
Feature: High lumen output paired with strong efficiency — 15000 lumens at 140 lm/W and a 113W drive mean brighter, more energy-efficient coverage. Business impact: Lower operating costs per delivered lumen and reduced cooling load due to better efficacy. Application: Large outdoor work zones, loading docks, and outdoor infrastructure in hazardous locations. Feature: Dimmable driver — facilitates precise light control, reducing waste during non-peak periods. Business impact: Energy cost savings over life of the fixture and better alignment with facility lighting plans and control systems. Application: Facilities with dimming controls or occupancy-based lighting strategies in hazardous environments. Feature: Hazardous-location certification and rugged housing — IECEx/ATEX compatibility, NEC/CEC compliance, IP66 ingress protection, and NEMA 4X rating. Business impact: Compliance assurance across global sites and enhanced reliability in harsh conditions. Application: Chemical plants, oil & gas sites, mining operations, and other classified locations. Feature: Robust construction and optics — die-cast aluminum housing, heat and impact resistant glass, 7x6 optical distribution for uniform coverage. Business impact: Extended maintenance intervals and consistent light quality across mounting heights. Application: Outdoor illuminations, yards, and perimeter areas requiring durable performance. Feature: Broad electrical compatibility — 100-277 Vac and 108-250 Vdc, 50/60 Hz, 25 mm entry, yoke mounting. Business impact: Easy integration with existing power systems and retrofit potential without major electrical work. Application: Industrial plants with mixed power systems and retrofit projects in hazardous areas.
Get a Quick Quote for a Eaton Crouse-Hinds FMVA15LCY-UNV1-76-M25
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds FMVA15LCY-UNV1-76-M25?
Enquire Now
FAQs
Installers should mount the unit on the supplied yoke, connect to a suitable 100-277 VAC or 108-250 VDC power source, and ensure the fixture is within the IP66-protected enclosure. Verify proper wiring, grounding, and compliance with local codes for Class I, Division 2 or Zone 2 locations. The 25 mm entry supports standard conduit connections and allows straightforward integration with control systems.
The FMVA floodlight carries IECEx and ATEX certifications, NEC/CEC compliance, IP66 ingress protection, and a NEMA 4X rating. It is designed for hazardous/classified locations and suitable for global deployment in oil & gas, chemical processing, and mining facilities.
Ideal for outdoor yards, walkways, and perimeter lighting in hazardous locations, as well as production floors where weather and contaminants are present. Its 7x6 optical distribution provides uniform coverage, while the yoke mount enables versatile positioning for docks, skid areas, and outdoor work zones.
With 15000 lumens at 140 lm/W and a 113W driver, the fixture delivers high brightness with excellent efficiency. The dimmable driver supports energy management strategies, reducing peak demand and enabling compatibility with lighting controls while maintaining essential visibility in hazardous areas.
Yes. It runs on 100-277 VAC or 108-250 VDC, accepts 50/60 Hz, and features a 25 mm entry for easy conduit connections. The die-cast aluminum housing and robust glass lens support field retrofits, and the dimmable driver integrates with common control schemes to optimize energy use and maintenance programs in hazardous environments.