Eaton GHG5114306L3001 Hazardous Area Receptacle - IP66
Part Number: GHG5114306L3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5114306L3001
Category
Quick Summary
Hazardous Area Receptacle safely interlocks power connections for equipment at oil, gas, and chemical sites. Maintenance teams face ingress and isolation challenges in harsh environments, risking downtime and non-compliance. This device meets NEC/CEC/IEC requirements and offers IP66 ingress protection along with NEMA 4X ruggedness for outdoor or classified spaces. It is designed for 20A, 250 VAC circuits in a 1/2" trade size, two-wire, three-pole configuration, and uses a durable nylon housing for long service life in demanding plants. Engineers appreciate IEC 60309 compatibility for plug-and-play integration across suppliers. The interlock design reduces arc-flash risk and simplifies maintenance planning, delivering safer operations and measurable cost savings for procurement teams.
Product Information
Extended Description
GHG5114306L3001 Eaton Crouse-Hinds: Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 20A, Two-wire, three-pole, Nylon, 1/2", 250 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5114306L3001
Product Length/Depth
3.5 in
Product Height
8.8 in
Product Width
4.8 in
Product Weight
2.78 lb
EAN
4250217437298
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
20A
Trade size
1/2"
Configuration
Two-wire, three-pole
Voltage rating
250 V AC
Material
Nylon
IEC 60309 Hazardous Area Pin and Sleeve Devices catalog page
Eaton Specification Sheet - GHG5114306L3001
Feature → Business Impact → Application: The IEC 60309 hazardous area interlock receptacle delivers a proven safe disconnect mechanism for 20A, 250 VAC circuits in a 1/2 inch trade size, two-wire, three-pole configuration. This reduces arc-flash exposure and minimizes unplanned downtime by ensuring proper interlock sequence during maintenance and shutdowns in hazardous environments such as oil, gas, and chemical facilities. Application: ideal for outdoor or classified locations requiring robust interlocks that comply with strict NEC/CEC IEC standards and support plug-and-play compatibility with multiple manufacturers. Feature → Business Impact → Application: IP66 ingress protection and NEMA 4X construction protect against dust, water jets, and corrosion, lowering maintenance costs and extending service life in aggressive environments. Application: suitable for offshore platforms, refineries, and chemical processing plants where reliable sealing translates to longer intervals between servicing. Feature → Business Impact → Application: Nylon housing offers chemical resistance and thermal stability, reducing wear in tough installations. Application: durable housing simplifies installation in tight spaces and supports long-term reliability. Feature → Business Impact → Application: 1/2" trade size with a 20A rating provides compatibility with common IEC 60309 devices, reducing wiring complexity and facilitating fast commissioning. Application: recommended for new builds and retrofit projects seeking compliant, scalable hazardous area interlock solutions. Feature → Business Impact → Application: Hazardous/Classified Locations and Zone 1/2, Class I ratings ensure regulatory alignment while supporting wire-tight safety practices. Application: essential for safety compliance during commissioning, maintenance, or shutdown procedures in combustible environments.
Get a Quick Quote for a Eaton Crouse-Hinds GHG5114306L3001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GHG5114306L3001?
Enquire Now
FAQs
When installing the GHG5114306L3001, verify the location falls under Hazardous/Classified Locations per NEC/CEC IEC guidelines and confirm Zone 1/2 or Division 2 requirements. Use proper IP66-rated seals and nylon housing hardware, mount on a stable panel or enclosure, and follow manufacturer torque specs for connector fixtures. Ensure correct polarity and secure wiring of the two-wire, three-pole configuration to maintain safe interlock operation during maintenance and tests.
The GHG5114306L3001 carries NEC/CEC/IEC standards alignment for hazardous locations, a Class I, Zone 1/2 and Division 2 hazardous rating, and a NEMA 4X enclosure with IP66 ingress protection. These certifications support safe operation in corrosive and wet environments and ensure compliance with industry requirements for offshore, refinery, and chemical processing applications.
Yes. The product is designed as an IEC 60309 hazardous area interlock receptacle and uses a standardized 1/2" trade size, compatible with common IEC 60309 pin-and-sleeve devices. This enables plug-and-play integration with compatible connectors and simplifies cross-vendor installation, reducing custom wiring and speeding up project timelines.
This interlock receptacle is ideal for oil and gas, chemical processing, and offshore environments where hazardous area containment and safe shutdown are critical. The 20A, 250 VAC rating, along with IP66 and NEMA 4X protections, supports reliable operation in harsh weather, chemical exposure, and high-dust conditions, while NEC/CEC/IEC compliance ensures regulatory alignment.
Expect reduced downtime due to reliable interlock sequencing and enhanced safety during maintenance, which lowers incident risk and arc-flash exposure. The rugged nylon housing and IP66/NEMA 4X protections minimize environmental wear, decreasing spare parts and service frequencies. Overall, the solution supports longer service intervals, faster maintenance, and improved regulatory compliance, delivering measurable total cost of ownership improvements.