Eaton GHG5124405L3001 Hazard Interlock Receptacle - IP66

Part Number: GHG5124405L3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5124405L3001

Quick Summary

Hazardous Area Interlock Receptacle provides safe, interlocked power connections for 3-phase equipment in hazardous locations. Maintenance teams struggle with accidental energization and noncompliant connectors that slow startup or violate codes. This interlock meets NEC/CEC IEC specifications and provides Class I Zone 1/Zone 2 ratings with IP66 and NEMA 4X, ensuring reliable protection in demanding environments. Beyond safety, it enables consistent IEC 60309 connectivity and straightforward maintenance planning, delivering measurable business value. Widely used in oil and gas, chemical processing, and mining applications, the rugged nylon housing and 1\" trade size support seamless installation across facilities while reducing wiring errors and downtime.

Product Information

Extended Description

GHG5124405L3001 Eaton Crouse-Hinds: Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 30A, Three-wire, four-pole, Nylon, 1", 3 phase 600 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5124405L3001
Product Length/Depth
4.7 in
Product Height
11.5 in
Product Width
6.6 in
Product Weight
5.11 lb
EAN
4250217436840
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
30A
Trade size
1"
Configuration
Three-wire, four-pole
Voltage rating
600 Vac
Material
Nylon
Feature: 30A at 600 Vac with a three-wire, four-pole configuration aligns with IEC 60309 interlock devices. Business Impact: Reduces mis-wiring, ensures correct interlock sequencing, and accelerates commissioning in hazardous environments. Application: Ideal for three-phase motors and equipment in chemical plants, refineries, and mining operations where safe energization is critical and uptime matters. Feature: Nylon housing provides rugged durability and IP66/NEMA 4X protection. Business Impact: Delivers reliable operation in washdown, dust, and corrosion-prone settings, lowering maintenance costs and downtime while extending service intervals. Application: Suitable for outdoor, offshore, and plant-floor installations where tough ingress protection is required and long-term reliability matters. Feature: Compliance with NEC/CEC IEC standards and Class I Zone 1/Zone 2 (Division 2) ratings. Business Impact: Helps you pass audits, maintain regulatory compliance across sites, and reduce risk of penalties or retrofits. Application: Used in hazardous locations across energy, chemical, and heavy manufacturing sectors, including oil & gas, mining, and processing plants. Feature: 1 inch trade size and IEC 60309 compatibility. Business Impact: Simplifies integration with existing plugs, fixtures, and cabling, minimizing spares and installation time while improving inventory control. Application: Supports retrofits and new builds that rely on standard IEC 60309 connectors in demanding environments. Feature: Interlock mechanism to enforce safe sequence and fault indication. Business Impact: Improves safety by preventing energization until enclosure is closed or keyed; reduces incident risk, injury potential, and insurance exposure. Application: Essential for control panels, process equipment, and powered enclosures in hazardous environments; compatible with Eaton Crouse-Hinds interlock ecosystems.

Get a Quick Quote for a Eaton Crouse-Hinds GHG5124405L3001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds GHG5124405L3001? Enquire Now

FAQs

When installing the GHG5124405L3001, ensure proper enclosure, secure mounting, and use approved IEC 60309 mating connectors. Verify correct wiring per three-wire, four-pole configuration and maintain the 1 inch trade size as specified. Use appropriate seals and fittings to preserve IP66 rating in wet or dusty environments, and follow local hazardous-location wiring standards during terminations.
The interlock receptacle is rated for Class I Zone 1 and Zone 2 (Division 2) with a 30A, 600 Vac three-phase configuration. It complies with NEC/CEC IEC standards and provides IP66/NEMA 4X protection, which supports reliable operation in active hazardous environments and reduces risk during energization sequences in demanding industrial processes.
Yes. The GHG5124405L3001 uses a 1" trade size and IEC 60309 interface, ensuring compatibility with standard hazardous-area plugs and cordsets. This simplifies retrofits and new installations alike, minimizes spare parts, and accelerates commissioning by preserving existing cabling layouts and connector mating practices.
KeyROI comes from reduced unplanned downtime, improved safety compliance, and faster maintenance cycles. The IP66/NEMA 4X protection and robust nylon housing resist washdown and corrosion, lowering repair costs. By enforcing proper interlock sequences, the device minimizes energization errors, protecting personnel and extending equipment life in harsh facilities.
The device carries NEC/CEC IEC standards alignment, Class I Zone 1 and Zone 2 ratings (Division 2), IP66 ingress protection, and NEMA 4X ruggedness. These certifications support compliance with hazardous-location wiring codes, safety mandates, and industrial maintenance guidelines, aiding audit readiness and site-wide regulatory conformity.