Eaton GHG5124405R3001 Hazardous Interlock Receptacle - IP66
Part Number: GHG5124405R3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5124405R3001
Category
Quick Summary
The Eaton Crouse-Hinds hazardous area interlock receptacle provides safe power isolation for industrial equipment in hazardous locations. Users struggle with accidental energization and corrosion in harsh environments, leading to costly downtime. This device carries IP66, NEMA 4X, and NEC/CEC IEC hazardous-location certifications, including Zone 1/Zone 2 and Division 2 ratings. Designed for IEC 60309 systems with M32 wiring, it supports high-load equipment while simplifying compliance. By combining rugged construction with certified protection, it delivers reliable, maintainable power connectors for demanding facilities.
Product Information
Extended Description
GHG5124405R3001 Eaton Crouse-Hinds: Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 32A, Three-wire, four-pole, Nylon, M32, 690 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5124405R3001
Product Length/Depth
4.7 in
Product Height
11.5 in
Product Width
6.6 in
Product Weight
5.11 lb
EAN
4250217427060
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
32A
Trade size
M32
Configuration
Three-wire, four-pole
Voltage rating
690 Vac
Material
Nylon
IEC 60309 Hazardous Area Pin and Sleeve Devices catalog page
Eaton Specification Sheet - GHG5124405R3001
Feature → Business Impact → Application: The 32A amperage rating paired with a 690 Vac supply capacity enables safe, high-load equipment operation without frequent upstream protection trips, reducing electrical nuisance and increasing line throughput in manufacturing cells that rely on IEC 60309 devices. This translates to measurable uptime gains and lower maintenance costs for industrial automation lines using hazardous-area interlocks. Application-wise, the part fits standard IEC 60309 interlock ecosystems and supports quick porting between machines, enabling streamlined line changes and modular expansion. Feature → Business Impact → Application: IP66 ingress protection combined with NEMA 4X enclosure and a nylon body delivers durable, corrosion-resistant performance in washdown zones and chemical environments, cutting replacement cycles and lowering total cost of ownership for marine facilities and processing plants. Application: harsh production floors, offshore rigs, and chemical plants demanding robust, seal-tight connectivity. Feature → Business Impact → Application: Hazardous-location compliance (Area classification: Hazardous/Classified Locations; NEC/CEC IEC standards) reduces regulatory risk and accelerates safe commissioning of new lines; engineers can document conformity quickly during audits. Application: panel assemblies in Zone 1/Zone 2 and Division 2 environments. Feature → Business Impact → Application: M32 trade size and three-wire, four-pole configuration simplify wiring and integration with existing control panels and plug-in devices, shortening installation time and ensuring compatibility with common automation components. Application: retrofits and new installations across industrial control architectures. Feature → Business Impact → Application: Nylon construction and sealed design offer improved chemical resistance and lower maintenance demands, supporting longer service intervals and predictable performance in challenging environments. Application: continuous-process facilities and offshore operations that prioritize reliability and lifecycle savings.
Get a Quick Quote for a Eaton Crouse-Hinds GHG5124405R3001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GHG5124405R3001?
Enquire Now
FAQs
Plan for the M32 wiring size and three-wire, four-pole configuration to ensure proper interlock operation. Verify panel cutouts and mating connector compatibility with IEC 60309 standards, and confirm enclosure sealing meets IP66/NEMA 4X requirements. Use appropriate gland sizes and seals to maintain ingress protection after installation.
It is certified for hazardous/classified locations with Zone 1/Zone 2 and Division 2 ratings, plus IP66 and NEMA 4X enclosure protections. These certifications ensure safe operation in explosive atmospheres, enable compliance with NEC/CEC IEC standards, and simplify regulatory audits for industrial and marine environments.
Yes. The device is designed for Class I, Zone 1 and Zone 2 locations, with corresponding Division 2 approvals. This means it can serve in areas with flammable gases or vapors and control panel applications requiring robust protective enclosures, reducing ignition risks and enabling safe maintenance routines.
The receptacle provides 32A at 690 Vac, configured as three-wire, four-pole, with an M32 trade size. It is compatible with IEC 60309 connectors and standard industrial equipment that requires hazardous-area interlock solutions, supporting reliable power delivery to heavy-duty motors and control circuits.
Durable Nylon housing and sealed IP66/NEMA 4X construction reduce corrosion and washdown wear, lowering replacement frequency. The reliable interlock mechanism minimizes accidental energization, improving uptime and safety, which translates to lower maintenance costs and a faster return on investment for facilities operating in harsh environments.