Eaton GHG5124409L3001 Hazardous Interlock Receptacle - IP66
Part Number: GHG5124409L3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5124409L3001
Category
Quick Summary
Eaton Crouse-Hinds hazardous area interlock receptacle safely connects power in hazardous locations across industrial facilities. Engineers often struggle with non-compliant interlocks that fail under washdowns, heat, or chemical exposure. This device delivers Class I Zone 1/Zone 2 and Division 2 approvals, IP66 protection, and a NEMA 4X rating under NEC/CEC IEC standards to streamline approvals. By integrating with IEC 60309 devices, it simplifies procurement and reduces downtime, delivering long-term reliability for hazardous area automation and control systems.
Product Information
Extended Description
GHG5124409L3001 Eaton Crouse-Hinds: Eaton's Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 30A, Three-wire, four-pole, Nylon, 1", 3 phase 250 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5124409L3001
Product Length/Depth
4.7 in
Product Height
11.5 in
Product Width
6.6 in
Product Weight
5.11 lb
EAN
4250217436796
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
30A
Trade size
1"
Configuration
Three-wire, four-pole
Voltage rating
250 V AC
Material
Nylon
IEC 60309 Hazardous Area Pin and Sleeve Devices catalog page
Eaton Specification Sheet - GHG5124409L3001
Feature: 30A, 250V AC, three-wire, four-pole configuration. Business Impact: Enables safe, high-load three-phase connections with reliable interlock control, reducing the risk of accidental energization in demanding environments. Application: Suitable for motors, pumps, and equipment in chemical plants and refineries. The result is improved uptime and safer start-up sequences. Feature: IEC 60309 compatibility and standardized geometry. Business Impact: Eases panel integration and partner plug compatibility, shortening installation time and lowering commissioning costs. Application: Applicable across constant-duty power distribution in hazardous areas. The outcome is faster project delivery and less field rework. Feature: IP66 ingress protection and NEMA 4X housing. Business Impact: Withstands washdowns, dust, and corrosive exposure, extending service life in harsh facilities. Application: Offshore platforms, onshore plants, and outdoor installations. Expect reduced maintenance and fewer part replacements. Feature: Nylon body construction. Business Impact: Lightweight, chemical-resistant housing improves handling and reduces overall system weight, while maintaining strength. Application: Environments with solvents and cleaning agents. Benefit: easier installation and lower handling risks. Feature: Hazardous-area certifications and NEC/CEC IEC compliance. Business Impact: Simplifies regulatory approvals and procurement, enabling faster adoption of safe interlock solutions. Application: Any project requiring Class I Zone 1/2, Division 2, IP66/NEMA 4X compliance. Result: reduced project risk and compliant electrical installations. Feature: Documentation and support readiness. Business Impact: Access to Eaton’s spec sheets and catalog pages accelerates design validation and vendor audits. Application: Engineering design reviews and procurement cycles in energy, chemical, and metal markets. Outcome: smoother audits and traceable equipment histories.
Get a Quick Quote for a Eaton Crouse-Hinds GHG5124409L3001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GHG5124409L3001?
Enquire Now
FAQs
Yes. The GHG5124409L3001 is designed as an IEC 60309 hazardous area interlock receptacle with a 1" trade size, three-wire four-pole configuration, and a 30A rating, making it compatible with standard IEC 60309 interlock devices used in Zone 1/Zone 2 and Division 2 environments.
Key specs include 30A amperage, 250V AC voltage rating, three-wire four-pole configuration, and a 1" trade size. Housing is nylon for chemical resistance, with IP66 protection and NEMA 4X suitability to support harsh-duty installations.
Ideal for oil & gas, chemical processing, mining, and offshore/rig installations. It supports safe energization and lockout in hazardous locations, meeting Class I Zone 1/Zone 2 and Division 2 standards while withstanding washdowns and corrosive processes.
The receptacle complies with NEC/CEC IEC standards and is rated for Hazardous/Classified Locations, Class I Zone 1/2 and Division 2, with IP66 ingress protection and a NEMA 4X enclosure rating, ensuring regulatory and installation approvals.
The rugged nylon housing and conforming hazardous-area ratings reduce maintenance cycles, prevent unplanned outages, and simplify audits. Its standardized IEC 60309 form factor speeds procurement and installation, delivering lower lifecycle costs and faster project ROI.