Eaton GHG5144405L3001 Hazardous Interlock Receptacle - IP66

Part Number: GHG5144405L3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5144405L3001

Quick Summary

The Eaton GHG5144405L3001 hazardous interlock receptacle is a rugged IEC 60309 device designed for safe power connection in hazardous locations. This rugged interlock solution minimizes downtime and wiring errors in explosive atmospheres by delivering secure engagement and reliable interruptibility, reducing risk during maintenance and shutdowns. It is certified for Hazardous/Classified Locations with NEC/CEC IEC standards, offering Class I, Zone 1, Division 2, Zone 2 ratings, and NEMA 4X and IP66 protection for harsh environments. This combination supports compliant, long-life performance in oil and gas, chemical processing, and heavy manufacturing. With a 60 A, 600 Vac rating and nylon construction, it delivers robust installation compatibility while helping you meet regulatory requirements and lower lifecycle costs.

Product Information

Extended Description

GHG5144405L3001 Eaton Crouse-Hinds: Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 60A, Three-wire, four-pole, Nylon, 1-1/4", 3 phase 600 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5144405L3001
Product Length/Depth
7.9 in
Product Height
18.7 in
Product Width
8.9 in
Product Weight
17.22 lb
EAN
4250217436598
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
60A
Trade size
1-1/4"
Configuration
Three-wire, four-pole
Voltage rating
600 Vac
Material
Nylon
60A three-wire four-pole IEC 60309 interlock receptacle provides robust power control for three-phase loads in hazardous areas. This delivers secure engagement and safe shutoff, reducing arc flash risk and maintenance exposure during line-up and disconnection. Ideal for production lines, pump skids, and process equipment in oil, gas, and chemical facilities. Protecting nylon housing paired with IP66 and NEMA 4X ratings delivers weatherproof, chemical-resistant performance. This reduces ingress of moisture and dust, extends service life in harsh environments, and lowers preventive maintenance costs. Use it on outdoor switchboards, offshore platforms, and chemical processing units where reliable interlocks are essential. Trade size is 1-1/4" with a three-wire, four-pole configuration for standardized, secure mating. This simplifies installation, minimizes mis-mating risk, and speeds field wiring during commissioning. It is especially beneficial for control panels, robotics interfaces, and downstream equipment that require standardized IEC 60309 connectors. Certified for Hazardous/Classified Locations under NEC/CEC IEC standards, including Class I Zone 1, Division 2, Zone 2. Combined with IP66 and NEMA 4X protection, the receptacle supports regulatory compliance, safer audits, and reduced liability. Suitable for oil rigs, chemical plants, and refining environments where certification discipline matters. Dimensions and weight are optimized for panel mounting and remote location installations, with a compact footprint (7.9 in L, 18.7 in H, 8.9 in W) and a manageable 17.22 lb. This combination simplifies enclosure planning, cable routing, and service accessibility in tiered automation cabinets and machine rooms.

Get a Quick Quote for a Eaton Crouse-Hinds GHG5144405L3001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds GHG5144405L3001? Enquire Now

FAQs

The GHG5144405L3001 interlock receptacle is designed to provide a secure power connection for three‑phase equipment in hazardous environments. It ensures proper engagement and disconnection, reducing arc flash risk and maintenance exposure. It is suitable for oil and gas, chemical processing, and heavy manufacturing where IEC 60309 compatible interlocks are required.
Yes. This receptacle is certified for Hazardous/Classified Locations, including Class I Zone 1, Division 2, and Zone 2. Installation should be performed by qualified personnel in accordance with NEC/CEC IEC standards, ensuring safe operation and regulatory compliance in Zone 1 environments.
The device provides 60A at 600 Vac in a three‑wire, four‑pole configuration. It uses a 1‑1/4" trade size and features a nylon housing rated IP66 and NEMA 4X for rugged, corrosion-resistant service. This combination supports reliable three‑phase power distribution in harsh locations.
Plan for proper mounting in accordance with IEC 60309 and NEC/CEC requirements, verify that mating plugs also meet IEC 60309 standards, and maintain IP66/NEMA 4X integrity at all times. Conduct periodic maintenance checks to confirm secure engagement, proper sealing, and intact protective gaskets to sustain safety and compliance.
Use the catalog number GHG5144405L3001 and the EAN 4250217436598 to locate official datasheets and catalog pages. Download the IEC 60309 Hazardous Area Devices catalog page and Eaton specification sheet to confirm ratings, wiring configurations, and installation guidance before purchasing and integrating into your project.