Eaton GHG5144405R3001 Hazardous Interlock Receptacle - IP66
Part Number: GHG5144405R3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5144405R3001
Category
Quick Summary
The Eaton Crouse-Hinds hazardous area interlock receptacle is designed to safely control power in hazardous locations. In demanding plants, misenergization and downtime cost time and safety; this interlock provides reliable locking and switching in a rugged Nylon housing. It delivers IP66 protection, NEMA 4X enclosure, and NEC/CEC IEC compliance for Zone 1/Class I, Division 2 locations. That combination reduces maintenance overhead and accelerates safe servicing during outages. Suitable for oil, gas, chemical, and mining environments, it supports industrial automation goals with extended life and lower total cost. The unit's 63A rating and IEC 60309 compatibility simplify field wiring and retrofit projects.
Product Information
Extended Description
GHG5144405R3001 Eaton Crouse-Hinds: Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 63A, Three-wire, four-pole, Nylon, M40, 690 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5144405R3001
Product Length/Depth
7.9 in
Product Height
18.7 in
Product Width
8.9 in
Product Weight
17.22 lb
EAN
4250217408168
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
63A
Trade size
M40
Configuration
Three-wire, four-pole
Voltage rating
690 Vac
Material
Nylon
IEC 60309 Hazardous Area Pin and Sleeve Devices catalog page
Eaton Specification Sheet - GHG5144405R3001
Feature → Business Impact → Application: The device delivers 63A current handling at 690 Vac in a three-wire, four-pole configuration, enabling high-load interlock functionality with precise switching. This translates to improved safety and reliable motor control in hazardous areas, ideal for large conveyors or pump trains in chemical plants. Application: supports oil & gas processing lines and mining equipment where dependable power-lock control reduces risk and downtime. Feature → Business Impact → Application: Nylon housing offers excellent chemical and impact resistance, increasing service life in corrosive environments and outdoor installations. This reduces maintenance costs and replacement frequency while preserving enclosure integrity in offshore or plant-yard settings. Application: use in marine environments or chemical facilities requiring IP66 and NEMA 4X protection. Feature → Business Impact → Application: IEC 60309 based interlock design provides standardized mating with pin-and-sleeve plugs, simplifying installation and retrofit. Application: accelerates project timelines for new builds or upgrades in industrial automation scenes. Feature → Business Impact → Application: Area classification and multiple ratings (Zone 1, Division 2, Class I) support regulatory compliance and safe operations. Application: procurement teams can specify a single solution for multiple hazardous-location applications. Feature → Business Impact → Application: Dimensional and rating consistency (M40, 7.9 in depth, 18.7 in height) enables predictable fit and wiring layouts. Application: field deployment in constrained spaces with reliable mounting.
Get a Quick Quote for a Eaton Crouse-Hinds GHG5144405R3001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GHG5144405R3001?
Enquire Now
FAQs
To install the GHG5144405R3001 in Class I Zone 1 locations, follow Eaton’s wiring diagrams and NEC/CEC IEC guidelines. Use the M40 connectors for secure mating with IEC 60309 plugs, ensure IP66 sealing, and verify a 63A, 690 Vac rating for the interlock circuit. Confirm proper enclosure integrity before energizing.
Key ratings include a 63A current capacity, 690 Vac nominal voltage, and a three-wire, four-pole configuration. The device uses a nylon body with IP66 protection and a NEMA 4X enclosure, making it suitable for hazardous locations requiring robust sealing and environmental resistance.
Yes. The product is designed for Zone 1/Class I and Division 2 locations, aligned with NEC/CEC IEC standards. Its IP66/NEMA 4X enclosure provides the necessary protection against dust and water ingress, supporting safe operation in multiple hazardous-location scenarios.
This interlock receptacle complies with NEC/CEC IEC standards and is rated for Hazardous/Classified Locations. It carries IP66 protection and a NEMA 4X enclosure, ensuring robust performance in demanding industrial environments and alignment with global electrical safety requirements.
The nylon body offers corrosion resistance and rugged durability, reducing maintenance cycles. IP66/NEMA 4X protection minimizes weather-related wear, lowering replacement costs and downtime. The standardized IEC 60309 interface also speeds up installation and retrofit projects, delivering faster ROI for facilities with hazardous-location power control needs.