Eaton GHG5144407R3001 Interlock Receptacle - IP66
Part Number: GHG5144407R3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5144407R3001
Category
Quick Summary
Eaton GHG5144407R3001 Interlock Receptacle delivers safe, reliable control for hazardous-area automation. In industrial deployments, startups can be slowed by equipment that isn’t certified for hazardous locations or protective housings that fail in tough environments. This interlock receptacle combines a 63A, 500 Vac rating with a nylon body that withstands chemicals, moisture, and wear. It carries NEC/CEC IEC certifications for Hazardous/Classified Locations, IP66 ingress protection, and a NEMA 4X enclosure rating, with Zone 1 and Division 2 suitability for offshore and plant applications. Designed for seamless IEC 60309 compatibility and three-wire, four-pole configurations, it simplifies wiring and panel integration. The result is safer operations, reduced maintenance, and lower lifecycle costs for facilities requiring compliant hazardous-area interlocks.
Product Information
Extended Description
GHG5144407R3001 Eaton Crouse-Hinds: Eaton's Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 63A, Three-wire, four-pole, Nylon, M40, 500 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5144407R3001
Product Length/Depth
7.9 in
Product Height
18.7 in
Product Width
8.9 in
Product Weight
17.22 lb
EAN
4250217408120
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
63A
Trade size
M40
Configuration
Three-wire, four-pole
Voltage rating
500 Vac
Material
Nylon
IEC 60309 Hazardous Area Pin and Sleeve Devices catalog page
Eaton Specification Sheet - GHG5144407R3001
63A current rating and 500 Vac capability enable robust interlock control for high-demand equipment in hazardous areas, while the three-wire, four-pole configuration ensures reliable signaling and power isolation. The nylon housing provides chemical resistance and durable operation in tough plants, reducing replacement cycles. This combination simplifies panel wiring and supports straightforward installation in new builds or retrofits. IP66 ingress protection and a NEMA 4X enclosure protect against dust, water jets, and corrosion, delivering longer service life in harsh environments and reducing field maintenance. IEC 60309 compatibility allows plug-and-play integration with existing connectors and distribution systems, accelerating project timelines and improving overall system reliability. Compliance with Hazardous/Classified Locations standards (NEC/CEC IEC) minimizes regulatory risk while enabling safer work practices. With M40 trade size, 63A rating, and a durable nylon body, installation remains straightforward across varied plant layouts, reducing commissioning time and total cost of ownership. The product’s weight and mounting geometry support stable installation on panels and enclosures, even in tight spaces, making retrofits and upgrades cost-effective. For operators, this translates to improved uptime, fewer unplanned outages, and more predictable maintenance planning in hazardous-area automation.
Get a Quick Quote for a Eaton Crouse-Hinds GHG5144407R3001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GHG5144407R3001?
Enquire Now
FAQs
The GHG5144407R3001 is designed for panel mounting with IEC 60309 compatibility and a 3-wire, 4-pole configuration. Its M40 trade size and nylon housing simplify installation in hazardous locations, enabling straightforward mounting on standard control panels or enclosures while maintaining IP66 and NEMA 4X protection. Consider using compatible gasketed enclosures to maximize seal integrity in demanding environments.
Key ratings include 63A amperage and 500 Vac voltage, with three-wire, four-pole configuration. These ratings guide conductor sizing, protective device selection, and interlock sequencing in safety circuits. Design should ensure compatible IEC 60309 connectors, appropriate overcurrent protection, and adherence to NEC/CEC IEC standards for Hazardous/Classified Locations while maintaining IP66/NEMA 4X enclosure integrity.
This interlock receptacle excels in oil and gas, chemical processing, and marine/offshore environments where hazardous locations are present. Its Zone 1 and Division 2 suitability, IP66 protection, and NEMA 4X enclosure support reliable operation in dusty, damp, or corrosive conditions, while IEC 60309 compatibility enables seamless integration with existing hazardous-area power distributions.
Certification highlights include NEC/CEC IEC standards for Hazardous/Classified Locations, NEC hazardous rating for Class I, Zone 1 and Division 2, and Class I, Zone 2. The device also carries IP66 ingress protection and a NEMA 4X enclosure rating, ensuring robust protection against dust, water, and corrosion in harsh environments.
Maintenance benefits arise from the nylon housing’s chemical resistance and the interlock’s rugged IP66/NEMA 4X protection, reducing corrosion-related downtime. ROI is driven by longer service life, fewer field repairs, easier installation with IEC 60309 compatibility, and improved uptime in hazardous locations, resulting in lower total cost of ownership and predictable maintenance planning.