Eaton GHG5144409L3001 Hazardous Area Interlock - IP66
Part Number: GHG5144409L3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5144409L3001
Category
Quick Summary
Hazardous area interlock receptacle provides safe, compliant electrical connectivity for three-phase equipment in mining, oil, and chemical plants. Maintenance teams struggle with unexpected energization, safety violations, and downtime when using non-rated devices in hazardous locations. This unit delivers IP66 ingress protection, NEC/CEC IEC standards compliance for hazardous/classified locations, and a NEMA 4X enclosure rating. Designed for IEC 60309 connectivity in 60A, 250 VAC systems, it simplifies procurement of rugged, compliant components and helps protect personnel and downstream equipment, reducing incident risk and downtime. For engineering and procurement teams, it also supports standardized interfaces and faster commissioning across sites, delivering measurable reductions in installation cycles and maintenance overhead.
Product Information
Extended Description
GHG5144409L3001 Eaton Crouse-Hinds: Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 60A, Three-wire, four-pole, Nylon, 1-1/4", 3 phase 250 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5144409L3001
Product Length/Depth
7.9 in
Product Height
18.7 in
Product Width
8.9 in
Product Weight
17.22 lb
EAN
4250217436550
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
60A
Trade size
1-1/4"
Configuration
Three-wire, four-pole
Voltage rating
250 V AC
Material
Nylon
IEC 60309 Hazardous Area Pin and Sleeve Devices catalog page
Eaton Specification Sheet - GHG5144409L3001
Feature: IEC 60309 hazardous area interlock receptacle design provides certified protection for hazardous locations and supports 60A, 250 VAC three-phase power. Benefit: Ensures safe energy control and reliable operation in challenging environments, reducing arc-flash exposure and speeding up changeouts in production lines. Application: Petrochemical plants and mining operations where compliant power interfacing is critical. Feature: Three-wire, four-pole configuration enables precise interlock control and secure mating with compatible plugs. Benefit: Improves electrical safety and simplifies wiring schemes, lowering commissioning time and minimizing field wiring errors. Application: Motor control centers and hazardous-area motor starters in heavy industries. Feature: Nylon housing with IP66 protection and NEMA 4X rating provides rugged, corrosion-resistant enclosure. Benefit: Extends service life in dust, water splash, and washdown environments, reducing maintenance cycles and replacement costs. Application: Offshore platforms, chemical plants, and marine facilities. Feature: Compliance to NEC/CEC IEC standards for hazardous locations ensures regulatory alignment. Benefit: Facilitates audits and reduces non-compliance risk, enabling smoother procurement and installation across multinational sites. Application: Global projects with Class I, Zone 1 requirements. Feature: Compatibility with Eaton Crouse-Hinds wiring devices and available technical literature (catalog pages and datasheets) supports fast deployment. Benefit: Streamlines sourcing, compatibility checks, and on-site installation, cutting lead times and stock complexity. Application: New builds and retrofit projects requiring standardized hazardous-area connectors. Feature: Durable construction supports long service life and predictable performance under demanding industrial conditions. Benefit: Low total cost of ownership through reduced downtime and fewer part substitutions. Application: Any high-load, hazardous-location application that demands reliable power interlock functionality.
Get a Quick Quote for a Eaton Crouse-Hinds GHG5144409L3001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GHG5144409L3001?
Enquire Now
FAQs
Install the GHG5144409L3001 in accordance with NEC/CEC IEC standards for hazardous areas. Ensure a suitable enclosure, proper bonding and grounding, and use matching IEC 60309 plug and receptacle configurations. Verify IP66 sealing and gasket integrity after installation, and follow lockout-tagout procedures during maintenance.
Yes. The device is designed for three-wire, four-pole configurations at 250 V AC with a 60 A amperage rating, conforming to IEC 60309 hazardous-area interlock specifications for reliable three-phase operation.
Yes. It carries NEC/CEC IEC standards compliance for hazardous/classified locations and an IP66/NEMA 4X enclosure rating, supporting safe operation, reliable performance, and compliance audits in Class I, Zone 1 environments.
Regularly inspect IP66 seals, verify gasket integrity, and check electrical connections for tightness. Use approved mating plugs, replace damaged Nylon housings promptly, and follow manufacturer datasheets for torque specifications and interlock testing during preventive maintenance cycles.
Standardized hazardous-area interlock connectors reduce part variety, speed up site commissioning, and simplify procurement. The robust IP66/NEMA 4X ratings lower downtime and maintenance costs while ensuring regulatory compliance across sites with Class I, Zone 1 requirements.