Eaton GHG5144409R3001 Interlock Receptacle - IP66

Part Number: GHG5144409R3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5144409R3001

Quick Summary

Hazardous area interlock receptacle provides safe, plug-and-play control connections for IEC 60309-compliant installations in chemical plants, oil rigs, and manufacturing lines. Many operators struggle with corrosion, dust ingress, and compliance gaps in hazardous locations. With NEC/CEC IEC certifications, IP66 protection, and a NEMA 4X rating, this interlock receptacle is engineered for Class I Zone 1, Zone 2, and Division 2 environments. Built in a nylon M40 housing and rated at 63A and 220-240 Vac, it delivers reliable power control while easing commissioning and maintenance for contractor teams and OEMs. This combination of rugged construct and standardization supports shorter project timelines and lower lifecycle costs.

Product Information

Extended Description

GHG5144409R3001 Eaton Crouse-Hinds: Eaton's Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 63A, Three-wire, four-pole, Nylon, M40, 220-240 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5144409R3001
Product Length/Depth
7.9 in
Product Height
18.7 in
Product Width
8.9 in
Product Weight
17.22 lb
EAN
4250217408113
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
63A
Trade size
M40
Configuration
Three-wire, four-pole
Voltage rating
220-240 Vac
Material
Nylon
Feature 63A amperage rating with a 220-240 VAC three-wire, four-pole configuration delivers higher-load interlock performance, reducing the risk of under-rated connections and preventing unexpected outages. Business Impact Improved reliability and faster lockout/tagout cycles translate to less downtime on critical equipment such as conveyors and pumps. Application Ideal for heavy-industrial lines in hazardous locations where IEC 60309 devices are the standard, including chemical plants and offshore facilities. Feature IP66 ingress protection and NEMA 4X enclosure in a Nylon M40 housing resist dust, water, and corrosive exposure, extending service life in harsh environments. Business Impact Lower maintenance costs and longer service intervals due to rugged materials and sealed design. Application Suitable for outdoor or wash-down areas where frequent cleaning occurs, maintaining electrical integrity without frequent replacement. Feature Area classifications and NEC/CEC IEC certifications (Class I Zone 1, Zone 2) ensure compliance with global hazardous-location codes. Business Impact Simplified project approvals and easier OEM integration, reducing design risk. Application Works with standard Eaton accessories and IEC 60309 pin-and-sleeve configurations for rapid integration. Feature Dimensions and weight (7.9 in L x 8.9 in W x 18.7 in H; 17.22 lb) support compatibility with common electrical enclosures and mounting schemes. Business Impact Plug-and-play installation reduces field wiring time and allows faster commissioning. Application Fits production lines with limited space, improving overall plant ergonomics. Feature Nylon M40 construction and high-temperature tolerance address long-term durability concerns in demanding facilities. Business Impact Lower replacement cycles and better total cost of ownership. Application Ideal for marine, chemical, and oil-and-gas environments where exposure to humidity and chemical vapors is a concern.

Get a Quick Quote for a Eaton Crouse-Hinds GHG5144409R3001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds GHG5144409R3001? Enquire Now

FAQs

Installers should verify NEC/CEC IEC compliance and ensure the three-wire, four-pole configuration matches the controlled equipment. Mount using standard backboxes or enclosure interfaces designed for IEC 60309 devices, maintain IP66 integrity with gaskets, and follow lockout/tagout procedures. The unit's Nylon M40 housing simplifies mounting in tight spaces while sustaining ingress protection and mechanical stability.
The device is rated for 63A at 220-240 VAC, configured as three-wire and four-pole. It uses a Nylon M40 housing and provides IP66 protection with a NEMA 4X rating. The combination supports robust performance in hazardous locations while aligning with IEC 60309 standards.
Yes. The product is certified for Hazardous/Classified Locations, compatible with Class I Zone 1 and Zone 2 applications. Its NEC/CEC IEC certifications, along with IP66/NEMA 4X protection, ensure reliable operation in these hazardous locations and simplify regulatory compliance.
The interlock receptacle complies with NEC/CEC IEC standards and IEC 60309, featuring Hazardous Area classifications. It carries IP66 protection and a NEMA 4X rating, supporting use in harsh environments such as chemical plants and offshore facilities, while meeting area classification requirements for hazardous locations.
Rugged nylon construction (M40) and sealed IP66 enclosure reduce ingress and wear, lowering maintenance frequency. The device's compatibility with standard IEC 60309 accessories and field-proven reliability translate to longer service intervals, lower downtime, and a favorable total cost of ownership in demanding industries.