Eaton GHG5154406R3001 Interlock Receptacle - IP66

Part Number: GHG5154406R3001
Manufacturer
Eaton Crouse-Hinds
Part number
GHG5154406R3001

Quick Summary

Eaton GHG5154406R3001 hazardous area interlock receptacle enables safe 3‑phase power switching in industrial facilities. When upgrading equipment in classified locations, engineers face compatibility, regulatory, and reliability challenges that slow projects. This device meets IEC 60309 and NEC/CEC expectations, delivering IP66 ingress protection, NEMA 4X enclosure strength, and Zone 1/Zone 2 (Class I) hazardous area ratings for dependable operation. With Nylon construction and a 125 A three‑wire, four‑pole configuration, it supports robust performance and easier installation. For plant upgrades, it reduces downtime, simplifies compliance, and aligns with safety programs while enabling reliable powered interlock control in demanding environments.

Product Information

Extended Description

GHG5154406R3001 Eaton Crouse-Hinds: Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle, 125A, Three-wire, four-pole, Nylon, M63, 380-415 Vac
Product Name
Eaton Crouse-Hinds series IEC 60309 hazardous area interlock receptacle
Catalog Number
GHG5154406R3001
Product Length/Depth
226.06 mm
Product Height
535.94 mm
Product Width
254 mm
Product Weight
12.5 kg
EAN
4250217407987
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1 Class I, Zone 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Amperage Rating
125A
Trade size
M63
Configuration
Three-wire, four-pole
Voltage rating
380-415 Vac
Material
Nylon
Feature → Business Impact → Application: 125 A, three‑wire, four‑pole configuration enables high‑current interlock control with precise sequencing, reducing startup times and improving equipment safety in heavy machinery applications. Application: presses, mixers, and conveyors in chemical plants. Feature → IP66 and NEMA 4X enclosure protects against dust, water, and corrosion, lowering maintenance costs and extending service life in washdown or offshore environments. Application: outdoor installations and marine facilities. Feature → Nylon housing offers rugged mechanical strength with resistance to chemicals, lowering replacement frequency and total cost of ownership. Application: harsh chemical plants and oil & gas sites. Feature → M63 trade size with IEC 60309 compatibility ensures standard interlock wiring and panel integration, speeding installation and reducing commissioning risk. Application: retrofit projects and new builds. Feature → Area classification ratings and NEC/IEC compliance provide regulatory confidence and safer operations, minimizing non‑compliance exposure. Application: hazardous locations including Zone 1/Zone 2 and Division 2 scenarios. Feature → 125 A rating supports industrial workloads while maintaining compact form factor, delivering reliable power for heavy equipment with minimal footprint. Application: large motors and interlocked control circuits in manufacturing lines.

Get a Quick Quote for a Eaton Crouse-Hinds GHG5154406R3001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds GHG5154406R3001? Enquire Now

FAQs

Installers should follow standard IEC 60309 interlock mounting practices, ensuring secure panel fitment for the M63 trade size, proper wiring of the three‑wire, four‑pole configuration, and correct termination using compatible 380-415 Vac cabling. Verify IP66 seals and NEMA 4X enclosure integrity after installation, and confirm compliance with Class I Zone 1/Zone 2 or Division 2 requirements before energizing.
The GHG5154406R3001 is rated for 125 A, with a voltage range of 380-415 Vac, configured as three‑wire, four‑pole. It uses a Trade size M63 and features a Nylon body. The enclosure provides IP66 protection and a NEMA 4X rating, suitable for hazardous area installations per NEC/CEC and IEC standards.
Yes. It is designed for hazardous/classified locations with NEC Class I ratings (Division 2, Zone 1, Zone 2) and is IP66/NEMA 4X rated, making it appropriate for oil & gas, chemical processing, and other demanding environments where reliable interlock control is required.
The device adheres to IEC 60309 hazardous area device standards, plus NEC/CEC compliance. It carries hazardous area classifications (Class I, Division 2; Zone 1/Zone 2), IP66 ingress protection, and a NEMA 4X enclosure rating to meet stringent industrial safety and environmental requirements.
The nylon enclosure and robust build deliver long service life in harsh environments, reducing maintenance frequency and replacement costs. Its reliable interlock operation minimizes unplanned downtime, supporting faster changeovers and safer shutdown sequences in hazardous area applications, which translates to lower total cost of ownership over the system’s life.