Eaton GHG9601955R0024 Ex-e Cable Gland - IP66/IP68
Part Number: GHG9601955R0024
Quick Summary
Ex-e cable gland provides safe, explosion-protected cable termination for non-armoured cables in hazardous locations. Engineers often struggle to maintain sealing integrity while meeting strict IECEx/ATEX requirements and fast installation schedules. This gland carries IECEx/ATEX certification, IP66/IP68 protection, and area classifications for hazardous environments, supporting compliant, reliable plant operation. By using a lightweight polyamide 6 long-thread gland with an M25 metric thread and non-armoured cable compatibility, you can reduce maintenance cycles and speed terminations without compromising safety. It finds application across oil & gas, chemical processing, and other heavy-industry facilities where safety, reliability, and compliance are non-negotiable.
Product Information
Extended Description
GHG9601955R0024 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-e cable gland, Non-armoured cable, Non-armoured gland, Polyamide 6, Increased safety, M25, Long thread
Product Name
Eaton Crouse-Hinds series Ex-e cable gland
Catalog Number
GHG9601955R0024
Product Length/Depth
42.5 mm
Product Height
29 mm
Product Width
29 mm
Product Weight
0.02 kg
EAN
4250217429439
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX
Ingress protection (IP) ratings
IP66 IP68
Protection type
Increased safety
Cable type
Non-armored Non-armoured
Gland type
Non-armoured
Type
Long thread
Thread Size
M25
Thread type
Metric
Material
Polyamide 6
Crouse-Hinds series CEAG GHG Non-metallic EX Cable Glands catalog page for North American applications
Enlargement Gland IECEx Certificate of Conformity
Enlargement Gland IECEx Certificate of Conformity
Enlargement Gland IECEx Certificate of Conformity
Eaton Specification Sheet - GHG9601955R0024
Feature: Increased safety with Ex-e protection. Benefit: Ensures safe terminations in hazardous locations, reducing risk of ignition and improving operator confidence. Application: Oil & gas, chemical plants, and mining facilities require robust safety barriers and verifiable compliance. Feature: IP66/IP68 ingress protection. Benefit: High-level sealing against dust and water ingress, extending equipment life in washdown and outdoor environments. Application: Offshore platforms, refineries, and plant exteriors—where harsh conditions demand durable enclosures. Feature: M25 long-thread gland design. Benefit: Simplifies installation with a secure, reliable seal and easier tightening, cutting installation time. Application: Control panels and junction boxes in space-constrained environments. Feature: Non-armoured, polyamide 6 construction. Benefit: Lightweight yet sturdy construction with chemical resistance, lowering handling costs and maintenance. Application: Sensitive process lines and factory floors with exposure to chemicals. Feature: IECEx/ATEX certification with area classification. Benefit: Regulatory compliance across global markets, enabling cross-border projects and safer commissioning. Application: Multinational facilities needing consistent hazardous-location approvals.
Get a Quick Quote for a Eaton Crouse-Hinds GHG9601955R0024
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GHG9601955R0024?
Enquire Now
FAQs
The gland is designed for non-armoured (non-armoured) cables and uses an M25 metric thread with a long-thread design. It accommodates standard non-armoured cable entries and is suited for applications requiring increased safety in hazardous locations. Ensure the cable outer diameter falls within the gland’s defined range for a proper seal.
GHG9601955R0024 carries IECEx/ATEX certification for hazardous areas and IP66/IP68 ingress protection. It is specified for Hazardous/Classified Locations and supports area classifications. These certifications ensure compliance with global safety standards and reliable performance in challenging environments.
Yes. The gland features an M25 metric thread with a long-thread design, enabling secure installation and robust sealing. This makes it ideal for panel ingress protection and connector integrity in space-constrained cabinets, reducing rework and ensuring consistent performance in demanding environments.
Absolutely. The Ex-e classification, IECEx/ATEX certification, and North American compatibility documentation support global deployments. For North American applications, reference the Crouse-Hinds North American catalog page and the IECEx certificate to verify compliance with local regulations and installation practices.
The polyamide 6 construction provides chemical resistance and lightweight handling, reducing maintenance strain and downtime. The robust IP66/IP68 seal minimizes ingress-related failures, lowering long-term repair costs. Combined with rapid, secure installation, the gland delivers faster project delivery and improved total cost of ownership in hazardous-location installations.