Eaton GHG9601955R0130 Ex-i Cable Gland - IECEx/ATEX
Part Number: GHG9601955R0130
Quick Summary
Ex-i cable gland for hazardous locations provides reliable cable sealing for industrial automation enclosures. Engineers often struggle with ingress protection, sealing integrity, and compliance when wiring equipment in harsh environments. This gland carries IECEx/ATEX approvals for hazardous/classified locations and IP66/IP68 ratings, with area classifications to support safe operation. Designed with a polyamide body and a long-thread M25 x 1.5, it enables quick installation and durable sealing, driving lower maintenance costs. For procurement and traceability, the 42.5 mm length, 29 mm width, and 0.018 kg weight help standardize installations across plants. This Ex-i gland is ideal for mining, chemical processing, water treatment, and other hazardous-area projects.
Product Information
Extended Description
GHG9601955R0130 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Ex-i cable gland, 8-10 mm cable sealing range, Blue, Polyamide, -40/-55°C up to +70°C, M25 x 1.5 Metric, Long thread
Product Name
Eaton Crouse-Hinds series Ex-i cable gland
Catalog Number
GHG9601955R0130
Product Length/Depth
42.5 mm
Product Height
29 mm
Product Width
29 mm
Product Weight
0.018 kg
EAN
4250959947277
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX
Ingress protection (IP) ratings
IP66 IP68
Type
Long thread
Thread Size
M25 x 1.5
Thread type
Metric
Material
Polyamide
Crouse-Hinds series CEAG GHG Non-metallic EX Cable Glands catalog page for North American applications
CEAG GHG Non-metallic Ex Cable Glands EU Type Examination Certificate
Crouse-Hinds series CEAG GHG Non-metallic EX Cable Glands operating instructions
Feature: 8-10 mm cable sealing range combined with a long-thread M25 x 1.5 metric interface and a tough polyamide body. Business impact: Delivers reproducible seals on mixed cable diameters, reduces field rework, and speeds panel wiring. Application: Ideal for control panels in process plants, water treatment, and packaging lines where cable ingress is a risk. Feature: IECEx/ATEX approvals for hazardous/classified locations and IP66/IP68 protection. Business impact: Demonstrates global compliance and lowers certification time for new builds. Application: Suitable for zones 1 and 2, mining operations, oil and gas facilities, and any facility needing robust explosion protection. Feature: Long-thread design and metric connectivity enable secure retention with built-in sealing. Business impact: Improves mechanical stability against vibration and external loads, extending gasket life. Application: Retrofitting existing enclosures or integrating into new installations that demand reliable seals under dynamic conditions. Feature: Clear product specifications and readily accessible installation resources. Business impact: Reduces downtime and procurement risk by matching catalog data and providing official instructions. Application: Tight integration with Eaton Crouse-Hinds gland families and compatibility with standard conduit systems.
Get a Quick Quote for a Eaton Crouse-Hinds GHG9601955R0130
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GHG9601955R0130?
Enquire Now
FAQs
This gland uses a metric M25 x 1.5 long-thread connection and seals cables in the 8-10 mm range. Ensure the enclosure opening accommodates the 42.5 mm length and 29 mm width, tighten to the recommended torque to compress the gasket, and verify IP66/IP68 integrity after installation. Suitable for control panels in industrial environments such as mining and chemical processing.
Yes. The Ex-i cable gland carries IECEx/ATEX approvals for hazardous/classified locations, supporting installation in zones 1 and 2 and other hazardous environments. It also carries area classifications to confirm safe operation within explosive atmospheres, streamlining global compliance for multi-site projects.
The gland provides an 8-10 mm cable sealing range, allowing a range of small to mid-sized cables to be sealed with a single gland type. This reduces the number of SKUs required, simplifies inventory, and speeds up retrofits or new installs in electrical enclosures while maintaining a reliable seal.
The gland offers IP66 and IP68 ingress protection, guarding against dust ingress and temporary or continuous immersion. It is designed for operation from -40°C to +70°C and is suitable for outdoor, damp, or chemically challenging environments common in mining, water treatment, and oil & gas facilities.
Using the Ex-i gland reduces maintenance downtime by delivering reliable seals quickly, lowering the risk of ingress-related failures. IECEx/ATEX certification simplifies regulatory compliance, while the robust polyamide body and long-thread interface shorten installation time and minimize field adjustments, yielding lower total cost of ownership over the equipment lifecycle.