Eaton Crouse-Hinds GUAC16 WOD Condulet - Hazardous Locations
Part Number: GUAC16 WOD
Manufacturer
Eaton Crouse-Hinds
Part number
GUAC16 WOD
Quick Summary
The GUAC16 WOD Condulet from Eaton Crouse-Hinds is a rugged conduit outlet box designed for hazardous locations. In demanding plants, engineers struggle to maintain enclosure integrity and safe terminations amid dust, moisture, and vibration. This enclosure carries NEC/CEC compliance, Hazardous/Classified Locations ratings, and robust NEMA protection for environments rated 3, 4, 7, and 9. By combining a Feraloy iron alloy body and cover with a 1/2 inch trade size and a 3 inch cover opening, it reduces field rework and improves service continuity. The GUAC16 WOD supports quick installation, reliable sealing, and long-term cost savings, making it ideal for automation panels, hazardous-area machinery, and mining or chemical processing applications.
Product Information
Extended Description
GUAC16 WOD Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover, 3" cover opening diameter, Feraloy iron alloy body and cover, C shape, 1/2"
Product Name
Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover
Catalog Number
GUAC16 WOD
Product Length/Depth
5.25 in
Product Height
3.5 in
Product Width
2 in
Product Weight
3.09 lb
UPC
782274459424
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4 7 9
Shape
C
Trade size
1/2"
Cover opening diameter
3"
Material
Feraloy iron alloy
Special features
Feraloy iron alloy cover
Crouse-Hinds series GUA Conduit Outlet Boxes catalog page
Condulet GUA and GUR Explosionproof Conduit Outlet Boxes UL certification
IF 1730 - GUA/EAB/EAJ Condulet Outlet Boxes
Eaton Specification Sheet - GUAC16 WOD
Industrial Fittings Bend Radius and Cubic Capacity Chart
Feature: Feraloy iron alloy body and cover. Business Impact: Delivers superior impact resistance and corrosion protection in harsh industrial settings, extending service life and reducing maintenance costs. Application: Chemical processing plants, mining sites, offshore installations, and other demanding environments where enclosure integrity is critical. Feature: 1/2 inch trade size with C-shaped design. Business Impact: Enables compact, versatile wiring options while minimizing space requirements and simplifying field terminations. Application: Control panels and compact automation cabinets where space is at a premium. Feature: 3 inch cover opening. Business Impact: Provides ample clearance for terminations and field fittings, reducing install time and rework. Application: Compact conduit runs with standard fittings in harsh environments. Feature: NEC/CEC compliance and Hazardous/Classified Locations rating. Business Impact: Ensures regulatory conformity, improves safety documentation, and reduces risk in regulated facilities. Application: Facilities handling flammable materials, dust, or pressurized environments requiring strict classifications. Feature: NEMA ratings 3, 4, 7, 9. Business Impact: Broad environmental protection against dust, water, corrosion, and explosive atmospheres. Application: Industries from outdoor petrochemical plants to mining and marine applications. Feature: Durable cover with Feraloy alloy. Business Impact: Enhanced impact resistance and longer service intervals, lowering total cost of ownership. Application: Maintenance-heavy installations where components face frequent access. These features collectively support installation efficiency, ongoing reliability, and regulatory peace of mind for automation projects in hazardous zones.
Get a Quick Quote for a Eaton Crouse-Hinds GUAC16 WOD
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GUAC16 WOD?
Enquire Now
FAQs
For safe installation in hazardous locations, follow the IF 1730 Condulet instructions and use appropriate seals and fittings rated for Class I/II, and Division 1/2 as required. The 1/2 in trade size supports standard conduits, while the 3 in cover opening provides space for terminations. Ensure watertight and dust- resistant sealing per NEC/CEC guidance and adhere to local code requirements.
Yes. The GUAC16 WOD is designed for NEC/CEC compliance with hazardous location ratings including Class I, Division 1 and Division 2, as well as Class II and Class III where applicable. This ensures proper electrical protection for ignition hazard scenarios across many industrial settings, reducing compliance risk during audits and inspections.
The GUAC16 WOD uses a 1/2 inch trade size and a C-shaped body to accommodate common conduit and fittings used in automation panels. It pairs with Condulet family accessories and installation sheets such as IF 1730 for reliable compatibility. Always verify conduit type and fitting ratings against your project’s environmental classifications.
This enclosure carries NEMA ratings 3, 4, 7, and 9, providing protection against rain, corrosion, and explosive atmospheres. It is suitable for outdoor industrial plants, chemical processing facilities, mining operations, and offshore environments where hazardous-location approval and rugged enclosure performance are required.
The GUAC16 WOD’s durable Feraloy iron alloy construction reduces corrosion-related maintenance and enclosure failures, lowering downtime. Its compact size and straightforward installation minimize labor costs, while NEC/CEC compliance streamlines regulatory work. Over the asset life, these factors translate to lower total cost of ownership and higher uptime in hazardous-area installations.