Eaton Crouse-Hinds GUAC36 SS Condulet Outlet Box - 4X Hazardous
Part Number: GUAC36 SS
Manufacturer
Eaton Crouse-Hinds
Part number
GUAC36 SS
Quick Summary
Eaton Crouse-Hinds GUAC36 SS conduit outlet box is a rugged stainless-steel enclosure designed for hazardous-location conduit terminations in industrial plants. It helps protect critical electrical connections in harsh environments, reducing downtime and corrosion-related maintenance. The unit is certified for NEC/CEC compliance and rated for Hazardous/Classified Locations with NEMA 3 and 4X protection, delivering dependable performance in demanding applications. By combining corrosion resistance with robust enclosure integrity, the GUAC36 SS lowers total cost of ownership while ensuring safe, code-compliant installations. This solution aligns with oil & gas, chemical processing, and heavy industrial facilities, supporting reliable conduit management and fast installation in tight spaces.
Product Information
Extended Description
GUAC36 SS Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover, 3" cover opening diameter, Stainless steel, C shape, 1"
Product Name
Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover
Catalog Number
GUAC36 SS
Product Length/Depth
5.54 in
Product Height
3.6 in
Product Width
2.11 in
Product Weight
4 lb
UPC
662276520196
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4X
Shape
C
Trade size
1"
Cover opening diameter
3"
Material
Stainless steel
Crouse-Hinds stainless steel conduit, cable and wire management brochure
Crouse-Hinds series GUA Stainless Steel Conduit Outlet Boxes catalog page
Condulet GUA and GUR Explosionproof Conduit Outlet Boxes UL certification
Condulet GUA and GUR Explosionproof Conduit Outlet Boxes UL certification
Condulet GUA and GUR Explosionproof Conduit Outlet Boxes UL certification
IF 1779 - GUA Stainless Steel Condulet Outlet Boxes
IF 1779 - GUA Stainless Steel Condulet Outlet Boxes
Eaton Specification Sheet - GUAC36 SS
Industrial Fittings Bend Radius and Cubic Capacity Chart
Feature → Business Impact → Application: Stainless steel construction provides excellent corrosion resistance, increasing service life and reducing replacement costs in aggressive environments. This translates to lower maintenance intervals and predictable performance in chemical plants, offshore platforms, and mining sites. Feature → Application compatibility → Industry fit: The 1" trade size and 3" cover opening diameter enable straightforward wiring, ducting, and access for maintenance crews, supporting quick field installs and simplified conduit terminations. Feature → Compliance → Safety and risk management: NEC/CEC certification paired with hazardous-location ratings (Class I, Division 1 and 2; Class II, Division 1 and 2; Class III) and NEMA 3 4X containment ensures conformance with global standards while minimizing regulatory risk. Feature → Installation efficiency → Operational uptime: The Condulet GUA design offers reliable knockouts and mounting simplicity, reducing commissioning time and enabling rapid spares alignment with IF 1779 guidance. Feature → Performance in extreme conditions → Cost reduction: UL-certified for hazardous locations, the GUAC36 SS withstands dust, water ingress, and pressure, lowering failure modes and extending interval-based maintenance. Industry context: This enclosure is well-suited for high-humidity environments, chemical processing, and power-generation facilities where robust stainless-steel enclosures deliver tangible lifetime value.
Get a Quick Quote for a Eaton Crouse-Hinds GUAC36 SS
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GUAC36 SS?
Enquire Now
FAQs
What makes GUAC36 SS suitable for hazardous locations and how to install it? The box uses a 1" trade size with a 3" cover opening, stainless steel construction, and NEC/CEC compliance. Follow IF 1779 installation sheets for mounting, sealing, and termination procedures to ensure UL-listed performance in Class I, II, and III environments.
The GUAC36 SS is rated for Hazardous/Classified Locations, with NEC/CEC standards alignment and NEMA ratings of 3 and 4X. It is UL-certified for use in hazardous locations and suitable for environments requiring corrosion resistance and rugged enclosure integrity in industrial settings.
Yes. Its stainless steel construction and 4X NEMA rating provide superior corrosion resistance and protection against harsh chemicals, dust, and water ingress, making it suitable for offshore platforms, chemical plants, and mining facilities.
GUAC36 SS complies with NEC/CEC requirements and is designed for 1" conduit terminations with a 3" cover opening. It integrates with Crouse-Hinds GUA series accessories and installation sheets, helping maintain consistent field wiring practices and ease of retrofits.
The stainless-steelGUAC36 SS reduces maintenance costs through superior corrosion resistance and extended service life, lowers downtime from enclosure failures, and supports regulatory compliance, resulting in lower total cost of ownership in demanding industrial environments.