Eaton GUAM26 Condulet GUA Outlet Box - Hazardous Locations
Part Number: GUAM26
Quick Summary
Eaton GUAM26 Condulet GUA conduit outlet box with cover is designed for hazardous-location control panel enclosures. Facilities struggle to keep wiring protected and code-compliant in harsh environments. This enclosure meets NEC and CEC standards and is rated for Hazardous/Classified Locations, including Class I, Division 1 and 2, Class II, Division 1 and 2, and Class III, with NEMA ratings 3, 4, 7 and 9. Its compact M-shaped body and 3/4 in trade size streamline installation in industrial enclosures while delivering reliable protection and long-term cost savings. With Feraloy iron alloy construction and a 3 inch cover opening diameter, it supports versatile conduit configurations and reduces field modifications, minimizing downtime and maintenance costs.
Product Information
Extended Description
GUAM26 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover, 3" cover opening diameter, Feraloy iron alloy, M shape, 3/4"
Product Name
Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover
Catalog Number
GUAM26
UPC
782274465906
Product Length/Depth
4.38 in
Product Height
4.38 in
Product Width
2.88 in
Product Weight
2.65 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4 7 9
Shape
M
Trade size
3/4"
Cover opening diameter
3"
Material
Feraloy iron alloy
Crouse-Hinds series GUA Conduit Outlet Boxes catalog page
Condulet GUA and GUR Explosionproof Conduit Outlet Boxes UL certification
IF 1730 - GUA/EAB/EAJ Condulet Outlet Boxes
Eaton Specification Sheet - GUAM26
Industrial Fittings Bend Radius and Cubic Capacity Chart
Feature 3/4 inch trade size and 3 inch cover opening: The compact footprint enables clean, accessible wiring routes in tight control panels, reducing installation time and misrouting while meeting space constraints in industrial environments. This translates to faster maintenance and lower labor costs during panel upgrades or expansion. Application: ideal for compact enclosures in chemical processing plants or mining facilities where space is at a premium. Feature Feraloy iron alloy material: The high-strength, corrosion-resistant alloy provides robust protection against harsh conditions, extending service life in demanding locations and reducing replacement cycles. Benefit: lowers total cost of ownership and downtime due to component failure. Application: hazardous area enclosures near aggressive chemicals or abrasive dust. Feature M-shaped body and GUA series design: The M shape supports easier gasket seating and conduit alignment, improving installation reliability and sealing integrity. Benefit: enhances safety margins and reduces rework during field installation. Application: new-build or retrofit projects in automation closets or motor control centers. Feature NEC/CEC compliance with Class I, II, III ratings and NEMA 3, 4, 7, 9: The box is engineered to meet core regulatory requirements and ruggedness standards, simplifying approvals and inspection processes. Benefit: accelerates project timelines and ensures consistent compliance across sites. Application: petrochemical, metal processing, and offshore facilities where regulatory adherence matters. Feature 3/4" trade size with 3" cover opening and documented installation guidance: Compatibility with installation sheets IF 1730 and Crouse-Hinds references reduces field guesswork. Benefit: lowers commissioning risk and standardizes field practices. Application: electrical rooms and hazardous-area panels requiring well-documented procedures.
Get a Quick Quote for a Eaton Crouse-Hinds GUAM26
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GUAM26?
Enquire Now
FAQs
GUAM26 should be installed in accordance with IF 1730 instructions and Crouse-Hinds installation practices. The 3/4" trade size and 3" cover opening support dependable conduit routing, while the Feraloy iron alloy body provides robust protection in Class I, II, and III locations. Ensure proper sealing and grounding per NEC/CEC requirements to maximize safety and compliance.
GUAM26 is certified for Hazardous/Classified Locations and carries NEC/CEC compliance, with NEC hazardous ratings for Class I, Division 1 and 2, Class II, Division 1 and 2, and Class III, along with NEMA Ratings 3, 4, 7, and 9. UL certifications are reflected in its installation and safety documentation, supporting industry approvals.
GUAM26 features a length/depth of 4.38 inches, a height of 4.38 inches, and a width of 2.88 inches. The enclosure weighs 2.65 pounds, providing a compact yet sturdy solution for mounting in control panels and restricted spaces.
Yes. GUAM26 aligns with Eaton IF1730 installation sheets and the Crouse-Hinds technical literature, including the GUAM26 specification sheet and catalog pages. This compatibility simplifies field wiring, gasket seating, and conduit connections while ensuring consistent compliance across projects.
Choosing GUAM26 delivers improved safety, regulatory compliance, and reduced maintenance downtime thanks to rugged Feraloy construction, proven NEC/CEC conformity, and reliable sealing in hazardous environments. The design minimizes field modifications, accelerates commissioning, and lowers total cost of ownership for long-term operations.