Eaton Crouse-Hinds GUAT26 TB14 Condulet GUA - Hazardous
Part Number: GUAT26 TB14
Manufacturer
Eaton Crouse-Hinds
Part number
GUAT26 TB14
Quick Summary
GUAT26 TB14 Condulet GUA is a rugged conduit outlet box with cover for hazardous-location installations in industrial facilities. Maintenance teams struggle with safe, compliant enclosures in classified environments while meeting NEC/CEC requirements. This model delivers NEC/CEC compliance, NEMA ratings 3, 4, 7 and 9, and hazardous-location approvals for Class I, II and III locations. Built to endure harsh processes, the unit reduces downtime by simplifying wiring through a direct mounted terminal block and a compact T-shaped form. Choosing GUAT26 TB14 also supports scalable installation across the Condulet GUA family, improving procurement consistency and long-term maintenance planning. Engineers gain confidence from documented specs, easy field service, and consistent spare-part compatibility.
Product Information
Extended Description
GUAT26 TB14 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover, 3" cover opening diameter, Feraloy iron alloy, T shape, Direct mounted terminal block, 4 poles, 3/4"
Product Name
Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover
Catalog Number
GUAT26 TB14
UPC
782274242552
Product Length/Depth
5.25 in
Product Height
4.38 in
Product Width
2 in
Product Weight
4 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4 7 9
Shape
T
Trade size
3/4"
Cover opening diameter
3"
Material
Feraloy iron alloy
Special features
Direct mounted terminal block, 4 poles
Crouse-Hinds series GUA Conduit Outlet Boxes catalog page
Condulet GUA and GUR Explosionproof Conduit Outlet Boxes UL certification
IF 1730 - GUA/EAB/EAJ Condulet Outlet Boxes
Eaton Specification Sheet - GUAT26 TB14
Industrial Fittings Bend Radius and Cubic Capacity Chart
Feature: 3/4 in trade size with a 3 in cover opening supports standard conduit and terminal configurations in tight spaces, enabling seamless integration with common field devices. This design streamlines wiring paths, reduces panel depth, and shortens installation time for each enclosure by minimizing routing turns and eliminating redundant fasteners. Application: ideal for small-control circuits and compact motor starters in hazardous environments where usable footprint and reliability matter, such as chemical processing or upstream/downstream automation. Feature: Direct mounted terminal block with four poles provides a compact, integrated wiring interface. Business impact: reduces wiring harness length, lowers field assembly time, and minimizes error potential during panel retimings. Application: used in Condulet GUA series boxes across hazardous locations to speed assembly and maintenance, especially in restricted-control panels and step-down applications. Feature: Feraloy iron alloy housing delivers strong impact resistance and superior abrasion resistance in demanding environments. Business impact: extends service life, lowers replacement costs, and improves uptime in plants subject to mechanical stress, corrosion, or chemical exposure. Application: suits environments with chemical exposure, dust, and vibration, complementing NEC/CEC compliance. Feature: T-shaped form with dimensions 5.25 in L, 4.38 in H, 2 in W; 4 lb weight. Business impact: predictable footprint supports controlled space planning, easier mounting with standard brackets, and dependable enclosure alignment across installations. Application: supports standardized mounting in control panels, switchgear, and instrument enclosures, ensuring consistent fit within enclosure banks. Feature: NEC/CEC compliance, NEMA ratings 3, 4, 7, 9 and hazardous-location approvals (Class I/II/III). Business impact: streamlines regulatory documentation, enables faster approvals, and reduces risk during field commissioning. Application: essential for plant design reviews in oil & gas, chemical processing, mining, or any facility operating in hazardous locations.
Get a Quick Quote for a Eaton Crouse-Hinds GUAT26 TB14
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GUAT26 TB14?
Enquire Now
FAQs
GUAT26 TB14 is designed for hazardous locations under NEC/CEC with Class I, II, and III ratings and NEMA 3, 4, 7, 9. It fits standard Condulet GUA configurations and accepts a 3/4 in trade-size conduit with a 3 in cover opening. Suitable applications include control panels, junction boxes, and motor control centers in chemical plants, oil & gas facilities, and mining environments where a rugged, compliant enclosure is essential.
This model uses a 3/4 in trade size, 3 in cover opening, and a T-shaped body. It’s crafted from Feraloy iron alloy, features a 5.25 in length, 4.38 in height, 2 in width, and weighs 4 lb. It includes a direct mounted four-pole terminal block, delivering a compact, integrated wiring interface suitable for harsh industrial settings.
The direct mounted terminal block reduces wiring harness length and panel depth, speeding assembly and reducing wiring errors. Its compact 3/4 in trade size and 3 in cover opening support efficient cable routing, while NEC/CEC compliance and NEMA ratings ensure regulatory alignment, making startup and commissioning faster in oil & gas, chemical processing, and mining projects.
GUAT26 TB14 carries NEC/CEC compliance, NEMA ratings 3, 4, 7, 9, and hazardous-location approvals covering Class I, II, and III locations. This combination simplifies regulatory documentation, supports design approval processes, and reduces risk during field commissioning for industrial facilities operating in classified environments.
Key documents include the Crouse-Hinds GUA catalog page, IF 1730 installation sheets, the GUAT26 TB14 specification sheet, and UL certification references. Access to these resources facilitates correct selection, installation guidance, and compliance verification for hazardous-location enclosures.