Eaton GUAX26 WOD Condulet GUA conduit outlet box - Hazardous
Part Number: GUAX26 WOD
Manufacturer
Eaton Crouse-Hinds
Part number
GUAX26 WOD
Quick Summary
Condulet GUA conduit outlet box provides rugged protection for wiring in hazardous-location installations. Engineers often struggle with achieving reliable enclosures in classified spaces while meeting NEC/CEC and NEMA requirements. The unit carries NEC/CEC compliance with hazardous-location ratings (Class I, Division 1 & 2; Class II, Division 1 & 2; Class III) and NEMA ratings 3, 4, 7, 9. As part of the Eaton Crouse-Hinds Condulet family, it supports safer installations, easier maintenance, and predictable procurement for hazardous environments.
Product Information
Extended Description
GUAX26 WOD Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover, 3" cover opening diameter, Feraloy iron alloy body and cover, X shape, 3/4"
Product Name
Eaton Crouse-Hinds series Condulet GUA conduit outlet box with cover
Catalog Number
GUAX26 WOD
UPC
782274797083
Product Length/Depth
5.25 in
Product Height
5.25 in
Product Width
2 in
Product Weight
3.55 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4 7 9
Shape
X
Trade size
3/4"
Cover opening diameter
3"
Material
Feraloy iron alloy
Special features
Feraloy iron alloy cover
Crouse-Hinds series GUA Conduit Outlet Boxes catalog page
Condulet GUA and GUR Explosionproof Conduit Outlet Boxes UL certification
IF 1730 - GUA/EAB/EAJ Condulet Outlet Boxes
Eaton Specification Sheet - GUAX26 WOD
Industrial Fittings Bend Radius and Cubic Capacity Chart
Feature: Feraloy iron alloy body and cover provide exceptional ruggedness and corrosion resistance in demanding environments. Business Impact: Reduces the risk of enclosure failure and service interruptions in chemical plants, refineries, or mines. Application: Best suited for hazardous-location wiring where enclosure integrity drives safety and uptime. Feature: 3/4" trade size and 3" cover opening diameter enable straightforward wiring access and standard conduit connections. Business Impact: Speeds up installation and servicing, lowering labor costs and downtime. Application: Instrumentation panels and field-witted control enclosures in the process industry. Feature: NEC/CEC compliance with Class I, II, III hazardous ratings and NEMA ratings 3, 4, 7, 9 provide comprehensive protection. Business Impact: Facilitates regulatory acceptance and reduces risk during inspections, audits, and project handoffs. Application: Any process area expediting safe electrical installation in hazardous locations. Feature: UL explosion-proof certification and installation resources (IF 1730) support safer field service. Business Impact: Improves inspector buy-in and accelerates project approval, lowering total cost of ownership. Application: Industrial sites requiring verified explosion-proof enclosures. Feature: 5.25 in length and height with 2 in width offers compact, yet protective enclosure for wiring terminations. Business Impact: Maximizes space efficiency in crowded control rooms and equipment cabinets. Application: Small-form, high-risk installations in constrained electrical layouts. Feature: Integration with Condulet system families aids upgrade paths and maintenance. Business Impact: Reduces spare-part diversity and simplifies procurement, stocking, and service planning. Application: Retrofit projects and new builds across oil & gas, chemical, and mining sectors.
Get a Quick Quote for a Eaton Crouse-Hinds GUAX26 WOD
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds GUAX26 WOD?
Enquire Now
FAQs
GUAX26 WOD should be installed following the IF 1730 Condulet instructions and NEC/CEC requirements for hazardous locations. Ensure proper enclosure grounding, sealant use around conduit entries, correct torque on cover screws, and appropriate mounting hardware. Confirm compatibility with existing Condulet fittings and maintain clearances per NFPA guidelines to maximize safety and service life.
Yes. The GUAX26 WOD is designed as part of the Condulet GUA family, supporting standard Condulet fittings and 3/4" trade size wiring. Its X-shaped geometry and 3" cover opening diameter enable straightforward field wiring, service access, and straightforward upgrades within the Condulet ecosystem while maintaining hazardous-location integrity.
This enclosure carries NEC/CEC compliance and hazardous-location ratings (Class I, Division 1 & 2; Class II, Division 1 & 2; Class III) along with NEMA ratings 3, 4, 7, 9. UL explosion-proof certification supports industry acceptance and regulatory alignment. These certifications translate to safer installations, easier inspector sign-off, and reduced compliance risk for your project.
Typical applications include chemical processing plants, oil and gas refineries, mining operations, and water treatment facilities where wiring must remain protected in hazardous locations. The enclosure’s rugged Feraloy iron alloy construction and cover design are well-suited for environments with corrosive aerosols, contaminants, and high-heat conditions while supporting reliable field wiring.
The GUAX26 WOD offers durable protection that reduces frequency of enclosure failures and maintenance interventions. Its corrosion-resistant body and straightforward service access minimize downtime, lowering total cost of ownership. Over multiple project cycles, the enclosure contributes to higher system availability, lower replacement costs, and predictable procurement for regulated facilities.