Eaton LTK3845 Liquidtight Connector - Hazardous Locations

Part Number: LTK3845
Manufacturer
Eaton Crouse-Hinds
Part number
LTK3845

Quick Summary

LTK3845 liquidtight connector seals FMC conduits in hazardous locations. This solves moisture ingress and dust intrusion challenges common in harsh industrial settings. It is designed to meet NEC/CEC requirements and is rated for Class I, Division 2; Class II, Division 1; and Class III environments, ensuring safe operation where ventilation and cooling are constrained. With its low-profile design and 3/8" trade size, it delivers installation flexibility, reduced clearance needs, and reliable performance in tight panels. The combination of rugged malleable iron construction and non-insulated body supports durable, serviceable connections in demanding facilities while enabling compliant, traceable installations across North American markets.

Product Information

Extended Description

LTK3845 Eaton Crouse-Hinds: Eaton Crouse-Hinds series LTK liquidtight connector, FMC, 45° angle, Non-insulated, Malleable iron, Low profile, 3/8"
Product Name
Eaton Crouse-Hinds series LTK liquidtight connector
Catalog Number
LTK3845
UPC
784564001580
Product Length/Depth
2.25 in
Product Height
2.13 in
Product Width
2.13 in
Product Weight
0.22 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
Conduit type
FMC
Connector type
45° angle
Material
Malleable iron
Insulator
Non-insulated
Trade size
3/8"
Special features
Low profile
Feature: 45° low-profile angle enables compact routing and easier enclosure penetrations → Business Impact: frees up space and reduces cabinet depth requirements, speeding up install times and improving wire management in crowded electrical rooms → Application: panel boards and junctions in space-constrained hazardous locations. Feature: Malleable iron, non-insulated body delivers robust mechanical strength and consistent grounding paths → Business Impact: improved impact resistance and long service life in vibration-prone environments, lowering maintenance costs → Application: oil & gas, mining, and chemical-processing plants. Feature: FMC conduit compatibility with a 3/8" trade size reduces the need for adapters and custom fittings → Business Impact: lowers inventory complexity and material waste, accelerating commissioning → Application: modular FMC conduit systems in hazardous areas. Feature: NEC/CEC compliance with hazardous-location ratings (Class I Division 2; Class II Division 1; Class II Division 2; Class III) → Business Impact: minimizes regulatory risk and supports cross-border projects with proven certifications → Application: industrial facilities requiring strict code compliance and safety documentation. Feature: Canadian certification and UL listings for Canada usage → Business Impact: enables seamless procurement and installation across Canadian sites, reducing project delays → Application: multi-country installations and maintenance programs. Feature: Low-profile, non-insulated design reduces protrusions and simplifies terminal access in tight spaces → Business Impact: faster terminations and safer, cleaner installations → Application: retrofits and new builds in compact electrical cabinets.

Get a Quick Quote for a Eaton Crouse-Hinds LTK3845

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds LTK3845? Enquire Now

FAQs

When installing the LTK3845, ensure FMC conduit alignment matches the 45° angle, tighten to manufacturer torque specs, and verify non-insulated malleable iron body seating. Confirm the area classification and enclosure integrity, using appropriate seals and gaskets as specified. This reduces moisture ingress and maintains hazardous-location compliance during retrofit or new builds.
Key specs include a 45° angle connector, 3/8" trade size, FMC conduit type, malleable iron construction, and a non-insulated body. It weighs 0.22 lb with dimensions around 2.25 in length and 2.13 in height/width. It is designed as a low-profile fitting suitable for hazardous-classified locations under NEC/CEC standards.
Yes. The LTK3845 carries NEC hazardous-location ratings including Class I, Division 2, as well as Class II Division 1 and Class II Division 2, plus Class III. This makes it appropriate for electrical installations in hazardous industrial environments, such as chemical processing plants and oil and gas facilities, where containment and protection are critical.
The LTK3845 complies with NEC/CEC standards and is rated for Class I Division 2, Class II Division 1 and 2, and Class III locations. It also carries Canadian certification listings and UL-related documentation, supporting cross-border procurement and installation in US and Canadian facilities.
The LTK3845 reduces installation time due to its compact, low-profile design and fewer adapters, lowering labor costs. Its malleable iron, non-insulated body withstands tough environments, reducing replacement cycles. Overall, it improves system reliability in hazardous locations, minimizes downtime, and simplifies compliance documentation for ongoing maintenance programs.