NCDC23 NCD Enclosure - Hazardous/Classified Locations

Part Number: NCDC23
Manufacturer
Eaton Crouse-Hinds
Part number
NCDC23

Quick Summary

NCDC23 NCD Enclosure is a rugged control cabinet housing designed for hazardous locations in industrial facilities. Engineers and maintenance teams often struggle with sealing integrity, wiring access, and regulatory risk when installing equipment in Class I Division 2 environments. This enclosure delivers NEC/CEC compliance with a robust NEMA rating of 3, 4X, 7, and 12, providing solid protection in demanding conditions. Its compact 11.75 in height, 4.38 in width, and 3.81 in depth balance capacity with space constraints, while a 3-circuit through-feed design simplifies wiring and reduces installation time. By supporting MSR1 or MSR2 suffix compatibility, it offers flexibility for future upgrades and streamlined procurement for safer, more reliable automation.

Product Information

Extended Description

NCDC23 Eaton Crouse-Hinds: Eaton Crouse-Hinds series NCD enclosure, 3, Must be used with MSR1 or MSR2 suffix, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series NCD enclosure
Catalog Number
NCDC23
UPC
782274592381
Product Length/Depth
3.81 in
Product Height
11.75 in
Product Width
4.38 in
Product Weight
3.56 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2
NEMA Rating
3 4X 7 12
Number of circuits
3
Style
Through feed
Trade size
3/4"
Special features
Must be used with MSR1 or MSR2 suffix
Through-feed design simplifies wiring and supports 3/4" trade size, reducing installation time and minimizing conduit fittings in tight panels, which translates to measurable cost savings on site. The hazardous location protection and NEMA ratings—3, 4X, 7, 12—provide durable enclosure protection, lowering maintenance and ignition risk in chemical plants and oil & gas facilities. Compact dimensions (11.75 in H × 4.38 in W × 3.81 in D) with a lightweight 3.56 lb mass enable easier handling and quicker replacement during maintenance cycles, improving overall equipment uptime. Compatibility with MSR1 or MSR2 suffixes makes future upgrades and accessory integration straightforward, reducing retrofit complexity and spare-part inventory. The 3-circuit capacity supports common automation architectures while preserving interior space for wiring and devices, delivering predictable performance in harsh environments.

Get a Quick Quote for a Eaton Crouse-Hinds NCDC23

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds NCDC23? Enquire Now

FAQs

Plan for Class I, Division 2 installation with NEC/CEC compliance. Use MSR1 or MSR2 suffix accessories as required, route the 3/4" through-feed wiring neatly, and verify proper sealing and grounding to maintain NEMA protection.
Class I, Division 2 hazardous location rating with NEC/CEC standards, plus a NEMA rating of 3, 4X, 7, 12, suitable for corrosive and ignition-risk environments.
Yes. Designed for hazardous/classified locations, it meets Class I, Division 2 requirements and carries robust NEMA protection, making it appropriate for oil & gas, chemical processing, and similar applications.
It aligns with NEC/CEC standards and NEMA ratings (3, 4X, 7, 12) for hazardous locations. UL certifications for hazardous-area control enclosures are available via listed UL documents and Eaton’s data downloads.
Increased uptime and reduced maintenance costs come from proven hazardous-location protection, easier wiring and installation (through-feed 3/4"). Compatibility with MSR suffixes minimizes retrofit steps, cutting both labor and spare-part expenses over the system lifecycle.