Eaton Crouse-Hinds NCDC31 Enclosure - Class I, Division 2

Part Number: NCDC31
Manufacturer
Eaton Crouse-Hinds
Part number
NCDC31

Quick Summary

NCDC31 is an enclosure solution for hazardous locations, protecting electrical controls in industrial environments. Maintenance teams often struggle with keeping hazardous-area assemblies compliant while enabling safe, rapid wiring and access. This unit meets NEC/CEC standards, provides Class I, Division 2 hazardous-location rating, and a robust NEMA 3 4X 7 12 enclosure for tough environments. Designed for MSR1 or MSR2 suffix and through-feed 1 inch, it streamlines installation, minimizes wiring mistakes, and supports regulatory compliance across facilities. Its rugged construction supports reliable control panels in chemical, oil & gas, and manufacturing settings, delivering safety, compliance, and operational efficiency across your facilities.

Product Information

Extended Description

NCDC31 Eaton Crouse-Hinds: Eaton Crouse-Hinds series NCD enclosure, 1, Must be used with MSR1 or MSR2 suffix, Through feed, 1"
Product Name
Eaton Crouse-Hinds series NCD enclosure
Catalog Number
NCDC31
UPC
782274592466
Product Length/Depth
3.81 in
Product Height
7.25 in
Product Width
4.38 in
Product Weight
3.09 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2
NEMA Rating
3 4X 7 12
Number of circuits
1
Style
Through feed
Trade size
1"
Special features
Must be used with MSR1 or MSR2 suffix
Feature: Through-feed design and 1" trade size simplifies internal wiring and panel layout. Benefit: Reduces install time and wiring errors, lowering labor costs and project schedules while improving electrical clearances in compact control cabinets. Application: New installations or retrofits in hazardous-area panels where space is limited. Long-tail keywords: through-feed enclosure, 1 inch trade size enclosure. Feature: NEMA 3, 4X, 7, 12 protection offers superior ingress and corrosion resistance. Benefit: Extends service life in outdoor, washdown, or corrosive environments, reducing maintenance costs. Application: Outdoor substations, chemical plants, or offshore facilities. Long-tail keywords: NEMA rated enclosure, corrosion-resistant control enclosure. Feature: Class I, Division 2 hazardous-location rating ensures regulatory compliance for hazardous areas. Benefit: Enables safe operation of electrical controls in classified locations, lowering risk and avoiding costly non-compliance penalties. Application: Oil & gas, refinery, and other hazardous-process environments. Long-tail keywords: hazardous location enclosure Class I Division 2, NEC/CEC compliant enclosure. Feature: MSR1/MSR2 suffix compatibility with Eaton control devices simplifies integration. Benefit: Streamlines procurement and retrofit projects by ensuring device compatibility, reducing engineering effort. Application: Retrofit projects and new installations using Eaton MSR components. Long-tail keywords: MSR suffix compatibility, Eaton control stations. Feature: 1 circuit, 1" trade size, through-feed configuration optimizes panel density. Benefit: Maximizes available space while maintaining clear wiring routes and dependable connections. Application: Compact control panels in constrained spaces. Long-tail keywords: 1 circuit enclosure, 1" trade size enclosure. Feature: Compact dimensions (3.81 in depth, 7.25 in height, 4.38 in width) with a 3.09 lb weight. Benefit: Easy handling, shipping, and on-site mounting, reducing installation time. Application: OEM and field service deployments. Long-tail keywords: compact enclosure dimensions, lightweight hazardous-location enclosure.

Get a Quick Quote for a Eaton Crouse-Hinds NCDC31

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds NCDC31? Enquire Now

FAQs

NCDC31 is designed to work with MSR1 and MSR2 suffixes, simplifying device compatibility for Eaton control systems. This compatibility reduces engineering time during design and installation, ensuring a seamless fit for hazard-rated control stations. For retrofit projects, verify that the existing MSR components align with the enclosure’s through-feed access and terminal clearance to avoid rework.
NCDC31 carries NEC/CEC standards compliance, a Class I, Division 2 hazardous-location rating, and a NEMA rating of 3 4X 7 12. These certifications verify safe electrical control enclosure performance in classified environments and harsh conditions, supporting safe operation, regulatory compliance, and reduced risk of equipment failure in hazardous facilities.
NCDC31 has a product depth of 3.81 inches, height of 7.25 inches, and width of 4.38 inches, with a product weight of approximately 3.09 pounds. These compact dimensions enable easier installation in tight panels and space-constrained installations, while maintaining robust protection for the enclosed electrical components.
Yes. With a NEMA 3 4X 7 12 rating, NCDC31 is designed for outdoor, washdown, and corrosive environments commonly found in chemical plants, refineries, and offshore facilities. The enclosure provides reliable ingress protection and long-term durability, reducing maintenance intervals and guarding critical control equipment against moisture, dust, and corrosion.
Choosing NCDC31 yields faster installation due to through-feed design, reduced wiring errors, and compatibility with MSR components, resulting in lower labor costs. The hazardous-location rating and robust NEMA protection minimize downtime and maintenance expenses while ensuring compliance with NEC/CEC requirements, ultimately delivering safer, more reliable control panels and longer service life.