Eaton Crouse-Hinds PVML-5-UNV1-EM1 LED Light - IP66

Part Number: PVML-5-UNV1-EM1
Manufacturer
Eaton Crouse-Hinds
Part number
PVML-5-UNV1-EM1

Quick Summary

PVML-5-UNV1-EM1 LED light fixture provides emergency back-up illumination for industrial facilities. In harsh environments, outages and poor visibility can halt production; this unit ensures continuous visibility when power is interrupted. It features IP66 ingress protection, NEMA 4X enclosure, and NEC/CEC compliance to support safe operation in ordinary and non-hazardous locations. With 5000 lumens at 128 lm/W and a compact 43 W footprint, it delivers high-efficiency lighting with flexible installation and reduced total cost of ownership, making it a reliable choice for facilities aiming to improve uptime and safety while meeting industry standards.

Product Information

Extended Description

PVML-5-UNV1-EM1 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Champ PVML LED light fixture with emergency back-up, Cool white, 0-10V dimming, No guard, Tempered glass lens, 5000 lumens, 128 lm/W, Copper-free aluminum, No mounting module, Type V, 100-277 Vac, 43W
Product Name
Eaton Crouse-Hinds series Champ PVML LED light fixture with emergency back-up
Catalog Number
PVML-5-UNV1-EM1
UPC
662276968653
Product Length/Depth
13.13 in
Product Height
15.68 in
Product Width
12.75 in
Product Weight
32.7 lb
Area classification
Ordinary/Non-Hazardous Locations
Standards type
NEC/CEC
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lumens
5000
Lumens per watt
128
Color temperature
Cool white
Mounting Method
No mounting module
Optical distribution
Type V
Guard type
No guard
Voltage rating
100-277 Vac
Material
Cast copper-free aluminum
Lens material
Tempered glass
Special features
Emergency driver system
Dimming
0-10 V
Frequency rating
50/60 Hz
Power factor
> 0.90
Wattage
43 W
Feature → Business Impact → Application: Emergency driver system provides reliable back-up during outages, reducing downtime and enabling compliant egress in critical areas. Application: plant floors, corridors, and safety-critical zones where uninterrupted light is essential. Feature → High lumen output with excellent efficiency delivers 5000 lumens at 128 lm/W, lowering energy consumption and cooling loads while maintaining bright, clear illumination for workers and equipment. Application: manufacturing lines and maintenance areas requiring consistent visibility. Feature → Universal input 100-277 VAC simplifies installation across sites with mixed electrical infrastructure, decreasing stocking needs and on-site wiring complexity. Application: new installs and retrofits in facilities with variable power supply. Feature → Type V optical distribution and tempered glass lens optimize light spread and durability, supporting uniform coverage in large areas and reducing maintenance cycles. Application: warehouses and outdoor ingress paths in non-hazardous environments. Feature → Copper-free aluminum housing, IP66 and NEMA 4X protection, plus no guard requirements, deliver corrosion resistance and rugged performance in demanding environments while simplifying procurement and compliance checks. Application: outdoor lighting, wash-down zones, and damp locations where exposure to moisture or contaminants is a concern.

Get a Quick Quote for a Eaton Crouse-Hinds PVML-5-UNV1-EM1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds PVML-5-UNV1-EM1? Enquire Now

FAQs

PVML-5-UNV1-EM1 is designed for easy integration in ordinary/non-hazardous locations with a Type V light distribution. It ships without a mounting module, so installation typically requires a compatible mounting approach per project specs and the installation instructions IF 1918. The unit's IP66 and NEMA 4X rating provide dependable protection against dust and water ingress, enabling reliable placement in indoor and outdoor environments.
The fixture incorporates an emergency driver system that supports back-up operation, ensuring continuous illumination during power interruptions. With 5000 lumens and a 43 W draw, it delivers high visibility with energy efficiency, helping facilities meet life-safety requirements and maintain safe egress without frequent maintenance escalations.
PVML-5-UNV1-EM1 accepts 100-277 VAC and consumes 43 W, delivering 5000 lumens at 128 lm/W. It supports 0-10 V dimming for compatible control systems, enabling flexible scene lighting and energy management across different shift patterns and tasks.
The fixture is designed to meet NEC/CEC standards and carries a NEMA 4X enclosure with IP66 ingress protection, suitable for ordinary/non-hazardous locations. These certifications support safe operation, regulatory compliance, and broader adoption in industrial facilities with rigorous codes.
With 5000 lumens and high lumen-per-watt efficiency, the PVML-5-UNV1-EM1 reduces energy costs while providing reliable emergency illumination. The copper-free aluminum housing, tempered glass lens, and robust enclosure minimize maintenance and replacement needs, contributing to lower total cost of ownership and longer service life in industrial environments.