Eaton Crouse-Hinds SSTG 6 Ground Hub - Hazardous Locations

Part Number: SSTG 6
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
SSTG 6

Quick Summary

SSTG 6 Ground Hub from Eaton Crouse-Hinds provides rugged grounding connections for hazardous-area electrical enclosures. Installers often struggle with corrosion, sealing, and bonding integrity in Class I Zone 1 environments; this stainless steel hub simplifies installation and long-term reliability. It carries NEC/CEC compliance along with hazardous location ratings Class I Zone 1, Division 2 and NEMA 3/3R/4/4X/12, delivering robust protection and certification confidence. Designed for 2" trade-size systems, it supports industrial automation networks with durable grounding. By reducing maintenance needs and ensuring consistent bonding, it helps projects meet timelines and compliance budgets.

Product Information

Extended Description

SSTG 6 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Myers ground hub, Stainless steel, 2"
Product Name
Eaton Crouse-Hinds series Myers ground hub
Catalog Number
SSTG 6
UPC
784731100351
Product Length/Depth
4.05 in
Product Height
1.2 in
Product Width
3.21 in
Product Weight
1.34 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 3R 4 4X 12
Trade size
2"
Material
Stainless steel
The stainless steel construction delivers superior corrosion resistance in harsh environments, improving long-term reliability and reducing replacement costs. In practical terms, this translates to lower maintenance expenses and fewer unplanned outages in hazardous area installations. This hub provides a solid bonding point for conduit connections, enhancing electrical safety and system performance across automation networks. The 2" trade size ensures straightforward compatibility with standard conduit fittings, speeding up installation and reducing the need for adapters or rework. NEC/CEC compliance and hazardous location ratings Class I Zone 1, Division 2, Class II Division 1, Class II Division 2, and Class III give project teams confidence during audits and inspections, helping you stay on schedule. NEMA ratings 3, 3R, 4, 4X, and 12 extend protection against exposure to weather, moisture, and mechanical wear, minimizing ingress and downtime. With dimensions of 4.05 in length, 1.2 in height, and 3.21 in width, plus a weight of 1.34 lb, the SSTG 6 is easy to handle in constrained spaces and supports efficient field installation. The hub aligns with UL/CSA frameworks and installation guidelines, reducing training time for technicians and ensuring consistent bonding performance across sites.

Get a Quick Quote for a Eaton Crouse-Hinds SSTG 6

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds SSTG 6? Enquire Now

FAQs

SSTG 6 should be installed in accordance with NEC/CEC requirements for Class I Zone 1 and related hazardous locations. Verify that the connected enclosure and conduit fittings are rated for the same environment, use stainless steel hardware to preserve corrosion resistance, and follow the applicable installation sheets (such as IF 1461 guidance) to ensure proper bonding and sealing. This reduces potential arcing risks and maintains a robust earth reference for the system.
The stainless steel construction provides superior corrosion resistance, maintaining a solid bonding path over time. Its 2" trade size supports direct compatibility with standard conduit fittings, reducing contact resistance at joints. The hub is designed to meet NEC/CEC standards and hazardous location ratings, ensuring reliable grounding performance even in Zone 1 conditions, which helps prevent bonding degradation that could compromise safety and equipment protection.
Yes. SSTG 6 is specified for a 2" trade size system and complements other Myers ground hubs in the field. Its stainless steel construction and standard dimensions enable straightforward integration with common conduit fittings, ensuring seamless upgrades or retrofits in existing installations without extensive rework or special adapters, which saves time and reduces project risk.
SSTG 6 carries NEC/CEC compliance and hazardous location ratings including Class I Zone 1, Division 2, Class II Division 1, Division 2, and Class III. It is compatible with NEMA ratings 3, 3R, 4, 4X, and 12, providing robust protection against environmental exposure. UL certifications for grounding and bonding equipment further support regulatory compliance and safe operation in demanding industrial settings.
The corrosion-resistant stainless steel build and robust hazardous-location ratings reduce maintenance cycles and replacement costs in harsh plants. Quick installation with standard 2" fittings lowers labor time, minimizing downtime during commissioning and expansion. Over the equipment life, reliable bonding and protection from environmental ingress translate to fewer service calls and a quicker path to return on investment for industrial automation projects.