Eaton Crouse-Hinds TECK050 1S Cable Gland - Hazardous/Classified Locations
Part Number: TECK050 1S
Quick Summary
TECK050 1S cable gland provides rugged sealing for TECK armored cable in industrial settings. This gland addresses the persistent challenge of securing armored conductors while maintaining reliable ingress protection in harsh environments. Facilities operating in hazardous or classified locations require fittings that combine robust construction with regulatory compliance, and TECK050 1S delivers just that. It carries NEC/CEC compliance and hazardous-location ratings — including Class II, Division 1 and Class III — plus a NEMA 4 protection rating for outdoor or wet environments. By pairing a steel armoured gland with precise sizing for armor and outer sheath, it simplifies procurement and installation. This solution also suits OEM and maintenance teams seeking durable fittings with predictable performance for 1/2" NPT connections and TECK cables.
Product Information
Extended Description
TECK050 1S Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Steel, Outer sheath min/max: 0.52-0.65", General purpose, 1/2" NPT, Armor range min/max: 0.41-0.57"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK050 1S
UPC
782274117140
Product Length/Depth
2.93 in
Product Height
1.35 in
Product Width
1.35 in
Product Weight
2 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Steel
Thread Size
1/2"
Thread type
NPT
Armor (min/max)
0.41-0.57"
Outer sheath (min/max)
0.52-0.65"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK050 1S
Armoured steel construction delivers rugged durability and corrosion resistance, meeting NEMA 4 protection requirements for indoor and outdoor installations. This provides long-term reliability in harsh environments, reducing maintenance costs and downtime. The 1/2" NPT thread enables fast, standard conduit connections with common fittings, simplifying field installs and reducing labor time. Precise sizing for armor (0.41–0.57 in) and outer sheath (0.52–0.65 in) ensures a secure, leak-free seal on TECK armored cables, minimizing ingress and extending service life in hazardous locations. As a general-purpose armoured gland, it offers flexible use across motor controls, process equipment, and instrumentation, helping procurement teams standardize fittings across projects. Certified for NEC/CEC compliance and hazardous-area ratings, it supports regulatory alignment while lowering total cost of ownership. Installation compatibility with TECK cables and related fittings (such as IF 1417) reduces risk of mismatch and rework, accelerating project timelines. Industry context notes steel glands perform reliably under washdown, vibration, and temperature cycling common in mining, chemical processing, and oil & gas environments. This TECK050 1S gland is a practical choice for engineers seeking durability, compliance, and predictable performance.
Get a Quick Quote for a Eaton Crouse-Hinds TECK050 1S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK050 1S?
Enquire Now
FAQs
TECK050 1S is designed specifically for TECK armored cables and uses a 1/2 in NPT thread. It accommodates armor in the 0.41–0.57 in range and outer sheath 0.52–0.65 in, ensuring a proper seal when mated with standard gland adapters and TECK-compatible fittings. For best results, pair with TECK cable fittings and consult the IF 1417 instruction sheet for installation specifics.
TECK050 1S carries NEC/CEC compliance and hazardous-location ratings suitable for Classified Locations, including NEC hazardous rating Class II, Division 1 and Class III, with a NEMA 4 enclosure protection level. This combination supports safe operation in environments with dust, moisture, and potential explosive atmospheres while aligning with common industrial codes.
Industries such as mining, chemical processing, oil and gas, and heavy manufacturing benefit from TECK050 1S due to its rugged steel construction, armored cable compatibility, 1/2 in NPT fitting, and certification suite. Its performance in hazardous/classified locations makes it a reliable choice for equipment enclosures, motors, and instrumentation exposed to washdown, vibration, or harsh temps.
Ensure proper gland sizing by verifying armor and outer sheath measurements fall within the 0.41–0.57 in and 0.52–0.65 in ranges, respectively. Use a 1/2 in NPT gland with compatible TECK fittings, tighten to manufacturer torque specs, and follow IF 1417 guidance for TECK cable fittings. Verify NEMA 4 ingress protection and confirm NEC/CEC compliance after installation to maintain hazardous-location integrity.
TECK050 1S offers durable steel construction and reliable sealing for armored cables, reducing ingress risk and maintenance frequency in hazardous environments. By standardizing on a single gland type for TECK cables, maintenance teams lower stocking variety, shorten inventory checks, and achieve faster repairs, contributing to lower downtime and improved overall equipment effectiveness.