Eaton TECK050 4S Cable Gland - Hazardous Locations
Part Number: TECK050 4S
Quick Summary
TECK050 4S cable gland is designed to seal TECK armored cables in hazardous industrial locations. Engineers often struggle with securing robust, code-compliant penetrations in harsh environments where dust, moisture, and explosive atmospheres threaten equipment reliability. This armoured gland carries NEC/CEC Certifications with hazardous area ratings including Class II, Division 1 and Class III, plus a NEMA 4 protection rating to ensure dependable operation. With steel construction and a 1/2" NPT thread, it offers durable mounting and straightforward installation on TECK armored cables, while compact dimensions help save panel space. The result is faster implementation, fewer part variations, and improved uptime for critical automation and safety systems.
Product Information
Extended Description
TECK050 4S Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Steel, Outer sheath min/max: 0.82-0.98", General purpose, 1/2" NPT, Armor range min/max: 0.71-0.90"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK050 4S
UPC
782274117225
Product Length/Depth
2.93 in
Product Height
1.6 in
Product Width
1.6 in
Product Weight
0.64 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Steel
Thread Size
1/2"
Thread type
NPT
Armor (min/max)
0.71-0.90"
Outer sheath (min/max)
0.82-0.98"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK050 4S
Feature: Steel construction and armoured gland design deliver rugged mechanical protection and a reliable seal. Business Impact: Reduces field maintenance, minimizes leakage risk, and extends service life in harsh environments. Application: Ideal for TECK armored cables entering process enclosures in chemical plants or outdoor installations. Feature: Armor (min/max) 0.71-0.90" and Outer sheath (min/max) 0.82-0.98" ensure precise compatibility with common TECK cable diameters. Business Impact: Fewer field adaptations, lower inventory of gland sizes, and consistent ingress protection. Application: Supports standardized installation in hazardous locations with minimal tuning. Feature: 1/2" NPT thread and steel gland provide a robust mounting interface. Business Impact: Simplifies sourcing and installation, reduces tool burden, and improves torque retention under vibration. Application: Works with standard conduit entries on panels and enclosures handling TECK armored cables. Feature: Certifications and ratings NEC/CEC, NEC hazardous rating Class II, Division 1 Class III, and NEMA 4. Business Impact: Compliance assurance, smoother audits, and reduced risk of non-conformance. Application: Required in hazardous/classified locations across industries such as oil & gas, mining, and chemical processing. Feature: Compact form factor (2.93 in length, 1.6 in width and height) and armoured gland design optimize panel space. Business Impact: Higher enclosure packing density, faster installation, and lower installation costs. Application: Suitable for instrument panels and control cabinets with TECK armored cable penetrations. Feature: Documentation and installation support including IF 1417 TECK Cable Fittings, TECK catalog page, and datasheet. Business Impact: Accelerates design-in, ensures correct assembly, and reduces training time. Application: Used by installers and procurement teams to quickly verify compatibility and installation steps.
Get a Quick Quote for a Eaton Crouse-Hinds TECK050 4S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK050 4S?
Enquire Now
FAQs
TECK050 4S uses a 1/2" NPT thread on steel, designed for armoured TECK cables. For hazardous locations, mount through appropriate enclosures, seal with proper gaskets, and follow IF 1417 installation guidelines to ensure a reliable, code-compliant penetration and ingress protection.
Yes. The gland is certified under NEC/CEC with hazardous area ratings that support Class II, Division 1 and Class III locations, and it carries a NEMA 4 rating for rain, washdown, and dusty environments, aiding regulatory compliance.
The gland is made of steel, with a 1/2" NPT thread size. It is compatible with TECK armored cables having armor 0.71-0.90" and outer sheath 0.82-0.98", and the overall footprint is 2.93 in length by 1.6 in width and height.
This gland is designed for TECK armored cables with steel armoured glands and 1/2" NPT entries. For best results, verify cable outer sheath and armour dimensions (0.82-0.98" sheath, 0.71-0.90" armour) and consult TECK fittings and IF 1417 instructions for correct installation practices.
Official Eaton resources include the Crouse-Hinds TECK catalog page, IF 1417 TECK Cable Fittings instruction sheet, and the Eaton Specification Sheet for TECK050 4S. These documents provide dimensional data, installation steps, and performance certifications to expedite procurement and field setup.