Eaton TECK075 5 Cable Gland - NEMA 4 Hazardous Locations
Part Number: TECK075 5
Quick Summary
The Eaton TECK075 5 cable gland is designed to seal TECK armored cables in harsh industrial environments. Maintenance teams struggle with field replacements that reduce uptime and expose workers to hazardous dust, moisture, and sparks. This gland aligns with NEC/CEC requirements and supports hazardous locations with Class II, Division 1 and Class III ratings, plus a NEMA 4 enclosure. By combining rugged aluminum construction with a precise 3/4 in NPT thread and defined armor and sheath clearances, it streamlines installation and ensures long-term integrity. The result is improved reliability, easier compliance documentation, and lower total cost of ownership for facilities using TECK armored cables. Engineers will appreciate the documented compatibility with Eaton's TECK fittings and installation resources.
Product Information
Extended Description
TECK075 5 Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Aluminum, Outer sheath min/max: 0.88-1.06", General purpose, 3/4" NPT, Armor range min/max: 0.77-0.98"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK075 5
UPC
782274116693
Product Length/Depth
3.13 in
Product Height
2.13 in
Product Width
2.13 in
Product Weight
0.49 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Aluminum
Thread Size
3/4"
Thread type
NPT
Armor (min/max)
0.77-0.98"
Outer sheath (min/max)
0.88-1.06"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK075 5
Feature: Aluminum construction with an armoured gland provides durable, corrosion-resistant protection in demanding environments. Business Impact: Reduces maintenance costs and extends service intervals, improving uptime for critical control circuits. Application: Suitable for TECK armored cables in chemical, oil and gas, and heavy manufacturing facilities, where moisture and dust exposure are constant. Feature: 3/4 inch NPT thread standardization enables quick integration with common conduit fittings, minimizing installation time. Business Impact: Lower labor hours per installation and fewer field adjustments, accelerating project timelines. Application: Ideal for new builds and retrofit projects with existing 3/4" NPT fittings and gland assemblies. Feature: Defined armor (0.77–0.98 in) and outer sheath (0.88–1.06 in) ranges ensure reliable sealing across standard TECK armor sizes. Business Impact: Improved seal integrity reduces ingress risk and potential equipment damage. Application: Fits a wide array of TECK armored cables, enabling consistent field performance. Feature: Certifications including NEC/CEC compliance, hazardous location ratings (Class II, Division 1; Class III) and NEMA 4 enclosure rating. Business Impact: Supports regulatory compliance and safety governance, reducing audit findings. Application: Critical for installations in classified locations and enclosures requiring robust protection. Feature: Installation resources such as IF 1417 TECK Cable Fittings and Eaton TECK catalog pages enhance deployment quality. Business Impact: Streamlines procurement, reduces misfit risk, and provides official guidance for installers. Application: Ensures consistent, documented installation practices for industrial projects.
Get a Quick Quote for a Eaton Crouse-Hinds TECK075 5
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK075 5?
Enquire Now
FAQs
TECK075 5 uses a 3/4" NPT thread and aluminum armoured gland designed for TECK armored cables, ensuring straightforward integration with standard conduit fittings. Verify armor size within 0.77–0.98" and outer sheath within 0.88–1.06" to confirm a proper seal. Use Eaton’s IF 1417 TECK Cable Fittings guide for step-by-step installation and torque recommendations to minimize leaks and reduce rework.
The TECK075 5 is specified for Hazardous/Classified Locations with NEC/CEC standards, and it carries NEC hazardous ratings Class II, Division 1 and Class III, plus a NEMA 4 enclosure rating. This combination supports safe operation in environments with dust, moisture, and potential ignition sources, helping you meet regulatory and safety requirements while reducing audit findings.
A 3/4" NPT thread is a common standard in industrial fittings, ensuring high compatibility with most conduit systems and gland adapters. It simplifies procurement and field installation, lowers the risk of mismatched components, and speeds up commissioning. The TECK075 5’s thread works in conjunction with TECK armor sizes 0.77–0.98" and outer sheath 0.88–1.06", ensuring a reliable seal when correctly mated.
Installations with TECK armored cables in hazardous locations, where ingress protection and regulatory compliance are critical, benefit most. The gland’s NEMA 4 rating, hazardous location approvals, and robust aluminum construction translate to fewer field replacements, lower maintenance costs, and improved uptime. Access to Eaton’s catalog pages and the TECK installation sheets further accelerates deployment and reduces lifecycle cost.
Eaton provides several resources to support TECK075 5 installations, including the Crouse-Hinds TECK catalog page, IF 1417 TECK Cable Fittings instruction sheet, and the Eaton Specification Sheet for TECK075 5. These docs cover dimensions, torque, material specs, and recommended installation practices to ensure compliant and efficient deployments.