Eaton TECK075 5S Cable Gland - Armoured, 3/4" NPT, Hazardous Locations
Part Number: TECK075 5S
Quick Summary
Eaton TECK075 5S cable gland seals TECK armored cable for hazardous-location installations. Engineers often struggle with maintaining seal integrity, adequate strain relief, and ingress protection in harsh industrial environments. This gland meets NEC/CEC requirements and offers a NEMA 4 enclosure rating, supporting safe operation in wet or dusty plants. It is designed for Class II, Division 1 and Class III locations, ensuring compliance in mining, chemical processing, and heavy manufacturing. By delivering robust mechanical protection and straightforward installation, TECK075 5S reduces maintenance cycles and downtime. The gland's 3/4 inch NPT thread and steel armor compatibility also simplify retrofits and supplier standardization, aligning with broader automation infrastructure goals and long-term cost efficiency.
Product Information
Extended Description
TECK075 5S Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Steel, Outer sheath min/max: 0.88-1.06", General purpose, 3/4" NPT, Armor range min/max: 0.77-0.98"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK075 5S
UPC
782274117249
Product Length/Depth
3.13 in
Product Height
2.13 in
Product Width
2.13 in
Product Weight
1.17 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Steel
Thread Size
3/4"
Thread type
NPT
Armor (min/max)
0.77-0.98"
Outer sheath (min/max)
0.88-1.06"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK075 5S
Feature: Armoured steel gland provides robust mechanical protection for TECK armored cables, resisting wear in demanding installations. Business Impact: This reduces field damage, maintenance, and downtime in harsh environments. Application: Ideal for mining, metals processing, and heavy manufacturing where armored cables traverse exposed conduits. Feature: 3/4" NPT thread and standard TECK fitting compatibility. Business Impact: Simplifies mounting, procurement, and stock management, accelerating installation and reducing commissioning time. Application: Panel and field-inlet connections in automation and process systems. Feature: Area classification and NEC/CEC compliance. Business Impact: Improves regulatory alignment and reduces rework risk, protecting project timelines. Application: Hazardous and Classified Locations across chemical plants and refineries. Feature: NEMA 4 rating. Business Impact: Delivers effective ingress protection against dust and water, enabling outdoor or wash-down environments. Application: Plants with washdowns, outdoor equipment enclosures, and damp production floors. Feature: Defined armor and sheath dimensions (Armor 0.77-0.98", Outer sheath 0.88-1.06"). Business Impact: Ensures precise seal and cable compatibility, lowering the risk of improper fits. Application: TECK armored cables within specified size ranges in automation and material handling. Feature: Documentation and compatibility resources. Business Impact: Streamlines procurement and installation with official TECK catalogs and IF 1417 sheets. Application: Engineering teams standardizing hardware across multiple facilities.
Get a Quick Quote for a Eaton Crouse-Hinds TECK075 5S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK075 5S?
Enquire Now
FAQs
Yes. TECK075 5S is designed for TECK armored cables and uses a 3/4" NPT thread, ensuring secure mounting in standard conduit systems. Its armor and sheath size ranges (0.77-0.98" armor, 0.88-1.06" sheath) help verify fit with common cable dimensions. Follow Eaton's IF 1417 installation instructions for proper sealing, grounding, and strain relief in hazardous locations.
Armor range 0.77-0.98" and outer sheath range 0.88-1.06" ensure a tight, compliant seal with TECK armored cables. This precision supports consistent ingress protection and maintains seal integrity across production tolerances, reducing the chance of leaks, moisture ingress, or field rework in demanding environments.
TECK075 5S is well-suited for industries with harsh or hazardous environments, including mining, chemical processing, oil and gas, power generation, and heavy manufacturing. It is ideal where TECK armored cables require reliable sealing, strain relief, and protection against dust and moisture in classified locations.
The gland supports NEC/CEC standards, Hazardous/Classified Locations area classification, and a NEMA 4 rating. These certifications confirm suitability for hazardous areas, ensure regulatory alignment, and help avoid rework or delays during audits and installations in industrial facilities.
TECK075 5S reduces maintenance downtime through robust mechanical protection, precise fits, and certified performance. Standardized fittings streamline procurement, installation, and future retrofits, lowering lifecycle costs and improving overall return on investment for automation and electrical infrastructure projects.