Eaton Crouse-Hinds TECK075 6S Cable Gland - Armoured 3/4 NPT
Part Number: TECK075 6S
Quick Summary
TECK075 6S cable gland from Eaton Crouse-Hinds provides armored cable termination for hazardous industrial locations. Many installers struggle to maintain enclosure integrity and regulatory compliance in harsh environments. It complies with NEC/CEC standards and is rated for Hazardous/Classified Locations, including Class II, Division 1 and Class III, with a NEMA 4 enclosure protection rating. The gland is designed for general-purpose TECK armored cable and 3/4 in NPT fittings, enabling a reliable seal and straightforward installation. Using this gland helps shorten commissioning time, reduces field rework, and supports long-term maintenance costs by ensuring robust, code-compliant terminations.
Product Information
Extended Description
TECK075 6S Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Steel, Outer sheath min/max: 1.02-1.20", General purpose, 3/4" NPT, Armor range min/max: 0.91-1.12"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK075 6S
UPC
782274117263
Product Length/Depth
3.13 in
Product Height
2.13 in
Product Width
2.13 in
Product Weight
2.25 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Steel
Thread Size
3/4"
Thread type
NPT
Armor (min/max)
0.91-1.12"
Outer sheath (min/max)
1.02-1.20"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK075 6S
Feature: TECK075 6S uses a steel armored gland designed for TECK armored cable installations. Business Impact: Provides superior mechanical protection and enclosure integrity in harsh environments, reducing wear on cable conductors and minimizing ingress paths. Application: Ideal for control panels and field junctions in chemical plants, mining sites, or refineries. Feature: 3/4" NPT thread with armor range 0.91–1.12" and outer sheath range 1.02–1.20". Business Impact: Ensures compatibility with standard conduit fittings and a wide cable range, reducing inventory complexity and installation time. Application: Works with common TECK armored cables in enclosures, accelerating commissioning and reducing change orders. Feature: NEC/CEC compliance and hazardous location ratings (Class II, Division 1; Class III) plus NEMA 4 enclosure protection. Business Impact: Improves regulatory confidence, eases audits, and lowers risk of non-compliance penalties. Application: Suitable for automation cabinets in hazardous environments. Feature: General-purpose protection and armoured construction. Business Impact: Increases service life under cable flex and vibration, delivering lower maintenance costs. Application: Fits general automation and process control installations requiring robust seals. Feature: Availability of catalogs and datasheets (TECK catalog page, IF 1417 installation sheet, and spec sheet). Business Impact: Shortens specification time and improves onboarding for procurement teams. Application: Facilitates engineering reviews and routine sourcing for TECK armored cables.
Get a Quick Quote for a Eaton Crouse-Hinds TECK075 6S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK075 6S?
Enquire Now
FAQs
TECK075 6S uses a standard 3/4 in NPT thread and is designed for TECK armored cable. Ensure the enclosure opening accommodates a 3/4 in NPT gland, verify armor range (0.91–1.12 in) and outer sheath size (1.02–1.20 in), and follow the IF 1417 installation guidance to achieve a proper seal and compliant termination in hazardous areas.
TECK075 6S is specified for NEC/CEC compliance and is rated for Hazardous/Classified Locations, including Class II, Division 1 and Class III. It also carries a NEMA 4 enclosure rating, which supports protection against water and dust ingress, enabling safe operation in demanding industrial environments.
Ideal applications include control panels, junction boxes, and field enclosures that house TECK armored cables in chemical plants, mining sites, and other hazardous locations. The 3/4 in NPT thread and steel armoured construction provide robust sealing and mechanical protection, ensuring long-term reliability in automation equipment and process control setups.
Potential challenges include aligning the gland with the armor size and ensuring the outer sheath fits within the specified range. Use the defined armor (0.91–1.12 in) and sheath (1.02–1.20 in) measurements, pre-verify enclosure openings, and consult the TECK installation sheets to avoid leaks and ensure a compliant seal during commissioning.
Benefits include reduced downtime due to robust, code-compliant terminations, fewer field reworks, and longer service life of armored cables in harsh environments. By meeting NEC/CEC and NEMA 4 standards, it minimizes compliance risk and simplifies audits, delivering lower maintenance costs and faster deployment for automation projects.