Eaton TECK100 7 Cable Gland - Hazardous Locations

Part Number: TECK100 7
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
TECK100 7

Quick Summary

TECK100 7 cable gland is a rugged sealing solution for armored TECK cables used in hazardous locations across industrial facilities. Engineers often struggle with finding a gland that fits precise armor and sheath dimensions while meeting rigorous codes and installation schedules. This unit meets NEC/CEC standards and hazardous location classifications, including Class II, Division 1 and Class III, with a NEMA 4 enclosure rating for reliable protection. The aluminum gland supports 1" NPT connections and armor ranges of 1.08–1.29" and sheath 1.19–1.37", reducing field adaptation. With its compact footprint and standardized documentation, it streamlines procurement and field assembly, delivering cost savings and safer terminations across diverse TECK armored cable applications.

Product Information

Extended Description

TECK100 7 Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Aluminum, Outer sheath min/max: 1.19-1.37", General purpose, 1" NPT, Armor range min/max: 1.08-1.29"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK100 7
UPC
782274116723
Product Length/Depth
3.38 in
Product Height
2.4 in
Product Width
2.4 in
Product Weight
5.85 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Aluminum
Thread Size
1"
Thread type
NPT
Armor (min/max)
1.08-1.29"
Outer sheath (min/max)
1.19-1.37"
Feature: 1" NPT aluminum armoured gland provides a durable seal and fast, straightforward mounting. Business Impact: Reduces commissioning time and maintenance—aluminum resists corrosion and the NPT connection ensures dependable interfaces. Application: Ideal for TECK armored cable terminations on pumps, motors, and control panels in factories and refineries. Feature: Armor range 1.08–1.29" and outer sheath 1.19–1.37" compatibility enables flexible installation with TECK armored cables, reducing the need for adapters and custom fittings. Business Impact: Lower inventory complexity and faster project timelines; Application: Retrofits and new builds where multiple cable sizes converge. Feature: NEC/CEC compliance, Class II, Division 1, Class III, and NEMA 4 rating provide robust regulatory and environmental protection. Business Impact: Minimizes compliance risk and insurance concerns; Application: Chemical plants, refineries, and mining operations. Feature: 1" thread size and NPT threading simplify mounting to equipment enclosures and conduit systems. Business Impact: Streamlines field terminations and serviceability; Application: New installations and upgrades across process and manufacturing facilities. Feature: Comprehensive documentation, including catalog pages and installation sheets, supports fast, code-ready deployments. Business Impact: Accelerates training, reduces misinterpretation, and improves procurement accuracy; Application: Field service, design reviews, and QA checks.

Get a Quick Quote for a Eaton Crouse-Hinds TECK100 7

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds TECK100 7? Enquire Now

FAQs

Yes. TECK100 7 uses a 1" NPT threaded gland and is designed for TECK armored cable. The aluminum gland accommodates armor 1.08–1.29 inches and outer sheath 1.19–1.37 inches, enabling secure terminations in Hazardous/Classified Locations. This compatibility supports reliable sealing, straightforward field assembly, and reduces rework.
TECK100 7 is developed to meet NEC/CEC standards and is suitable for Hazardous/Classified Locations (Class II, Division 1, Class III) with a NEMA 4 rating. These certifications ensure safe operation in demanding industrial environments and help align installations with regulatory requirements for equipment in hazardous settings.
The gland is ideal for armored TECK cable terminations in industrial facilities such as chemical plants, refineries, and mining operations where protection from dust, moisture, and hazardous atmospheres is essential. Its aluminum armoured design, 1" NPT connection, and dimension ranges support reliable, code-compliant terminations on control panels, motors, and other equipment.
TECK100 7 offers a robust 1" NPT aluminum gland with armor range compatibility and a precise outer sheath fit, enabling secure, leak-resistant terminations. The NEMA 4 enclosure rating provides protection against water and particulates, while NEC/CEC compliance ensures alignment with safety standards. Installation is facilitated by documented guidance such as catalog pages and installation sheets.
Official documentation includes the Crouse-Hinds TECK catalog page, IF 1417 TECK Cable Fittings instruction sheet, and the Eaton TECK100 7 specification sheet. These resources supply product data, installation guidance, and performance details to support design reviews, procurement decisions, and field maintenance.