Eaton TECK125 10 Cable Gland - Class II/Division 1
Part Number: TECK125 10
Quick Summary
TECK125 10 cable gland delivers rugged armoured sealing for hazardous locations in industrial environments. Engineers often face reliability gaps and regulatory hurdles when sourcing glands that fit TECK armored cable and survive harsh service. It carries NEC/CEC compliance and Class II, Division 1 hazardous location ratings, plus NEMA 4 protection for dependable outdoor or washdown environments. Aluminum construction and a 1-1/4 in NPT thread enable fast installations, reduce weight, and extend service life in demanding facilities. This combination minimizes maintenance cycles and improves regulatory audits, delivering measurable uptime gains for process control, manufacturing, and payload harnessing. Rely on TECK125 10 for proven industry performance in oil & gas, chemical processing, mining, and water treatment facilities.
Product Information
Extended Description
TECK125 10 Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Aluminum, Outer sheath min/max: 1.60-1.87", General purpose, 1-1/4" NPT, Armor range min/max: 1.49-1.79"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK125 10
UPC
782274116754
Product Length/Depth
4.3 in
Product Height
3.13 in
Product Width
3.13 in
Product Weight
5.1 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Aluminum
Thread Size
1-1/4"
Thread type
NPT
Armor (min/max)
1.49-1.79"
Outer sheath (min/max)
1.60-1.87"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK125 10
Armoured TECK gland is engineered for TECK armored cable, delivering robust sealing and strong mechanical retention in harsh environments. The design minimizes ingress of dust, water, and contaminants while resisting pull-out forces from vibration and equipment movement. In practice this translates to reduced downtime and fewer field repairs in plants such as mining operations, oil and gas facilities, and chemical processing plants. For installation teams, this gland pairs with existing TECK fittings to streamline sourcing and simplify inventory management. Aluminum construction lowers overall weight, making handling and mounting easier while offering corrosion resistance in harsh washdown or coastal environments. This lighter form factor also reduces mounting stress on enclosures and reduces wear on threaded connections over time. Across facilities that perform frequent inspections, aluminum glands help speed replacements during maintenance windows. Thread Size and NPT compatibility ensure standardization with common conduit systems, enabling leak-tight connections and faster rack or enclosure work. Armor range and outer sheath dimensions of 1.49-1.79" and 1.60-1.87" guarantee a precise fit for TECK armored cable, minimizing the risk of movement or misalignment in crowded electrical rooms. Certifications and regulatory alignment are built in, with NEC/CEC standards, Class II Division 1, and NEMA 4 protection to support safe operation in hazardous or washdown environments. Compatibility with TECK armored cable and drive to streamline procurement makes stocking simpler, reducing downtime when crews swap components during plant modifications. In practical terms, contractors report faster installation times, fewer call-backs, and predictable maintenance planning when using this gland with TECK cable systems.
Get a Quick Quote for a Eaton Crouse-Hinds TECK125 10
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK125 10?
Enquire Now
FAQs
TECK125 10 is specifically designed for TECK armored cables and uses a standard 1-1/4 in NPT thread, ensuring straightforward mating with compatible glands and enclosures. The armor range of 1.49–1.79 inches and outer sheath range of 1.60–1.87 inches provide a precise fit, reducing installation time and the need for additional adapters or shims.
Key performance specs include NEC/CEC compliance, Class II, Division 1 hazardous location rating, and a NEMA 4 enclosure protection level. The gland is aluminum and armoured, with a 1-1/4" NPT thread and defined armor and sheath ranges to fit TECK armored cable securely, ensuring robust ingress protection and long service life in tough environments.
Yes. The TECK125 10 is rated for Class II, Division 1 hazardous locations and carries NEMA 4 protection, making it appropriate for indoor outdoor installations, washdown areas, and zones with hazardous dust or splashing water. This combination supports safe operation and compliance in many industrial facilities.
This gland aligns with NEC/CEC standards and provides Class II, Division 1 hazardous location ratings. It also meets NEMA 4 for enclosure protection. These certifications help simplify compliance during audits and reduce the risk of nonconforming installations in hazardous or damp environments.
The gland reduces maintenance cycles by offering reliable sealing, corrosion resistance from aluminum construction, and a lighter weight for easier handling. Its precise fit minimizes leakage pathways and wear on threads, while standard 1-1/4" NPT connections speed up installation and stocking, lowering labor and inventory costs over the life of the installation.