Eaton TECK150 11 Cable Gland - Armoured, 1-1/2" NPT Class II

Part Number: TECK150 11
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
TECK150 11

Quick Summary

TECK cable gland seals and terminates armored TECK cables in hazardous locations. This robust aluminum armoured gland addresses common ingress and environmental challenges faced in industrial installations, delivering reliable performance in demanding settings. It is designed for 1-1/2" NPT threads and fits outer sheath diameters of 1.70 to 1.96 inches, with armor range 1.59 to 1.88 inches, ensuring a precise, vibration-resistant fit. For engineers and procurement teams, reliable glanding reduces downtime risk and simplifies maintenance in harsh environments. Leveraging NEC/CEC compliance and NEMA 4 protection, this gland supports both safety and long-term total cost of ownership, while remaining compatible with standard TECK armored cables and general purpose applications.

Product Information

Extended Description

TECK150 11 Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Aluminum, Outer sheath min/max: 1.70-1.96", General purpose, 1-1/2" NPT, Armor range min/max: 1.59-1.88"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK150 11
UPC
782274116778
Product Length/Depth
4.6 in
Product Height
3.6 in
Product Width
3.6 in
Product Weight
1.6 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Aluminum
Thread Size
1-1/2"
Thread type
NPT
Armor (min/max)
1.59-1.88"
Outer sheath (min/max)
1.70-1.96"
Feature → Business Impact → Application: Armoured aluminum construction provides corrosion resistance and strength while reducing weight, enabling easier handling and faster installations in field conditions. This directly lowers installation time and labor costs while improving reliability for outdoor and hazardous locations where ruggedness matters. Application: TECK150 11 is suited for armored TECK cables in industrial plants, with aluminum armoured glands that resist impact and corrosion in Class II, Division 1 environments. Feature → Business Impact → Application: Threaded 1-1/2" NPT connection ensures standardized, leak-proof sealing across a broad range of fittings, improving compatibility with existing conduit systems and reducing the risk of improper mating. Application: Use in general-purpose or hazardous area wiring where secure gland termination is essential. Feature → Business Impact → Application: Outer sheath and armor diameter compatibility (1.70–1.96" sheath, 1.59–1.88" armor) minimizes rework and inventory needs, enabling quick selection and consistent performance across TECK armored cables. Application: Field replacements and retrofit projects with tight enclosure tolerances. Feature → Business Impact → Application: NEC/CEC compliance and NEMA 4 rating provide regulatory assurance and environmental protection, helping maintenance teams avoid non-compliance penalties and unplanned downtime. Application: Critical installations in hazardous or classified locations requiring durable, code-compliant gland solutions. Feature → Business Impact → Application: ISO/IEC documentation and Eaton catalog pages provide ready access to installation guidelines and datasheets, streamlining procurement and QA processes. Application: Design reviews and commissioning where traceability and compliance are required.

Get a Quick Quote for a Eaton Crouse-Hinds TECK150 11

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds TECK150 11? Enquire Now

FAQs

To install TECK150 11, select the gland rated for 1-1/2" NPT threads and compatible outer sheath and armor diameters (1.70–1.96" sheath, 1.59–1.88" armor). Secure the gland to the enclosure, insert the TECK armored cable, and hand-tighten the coupling prior to final torque per the installation sheet IF 1417. Ensure seals are seated and verify ingress protection after commissioning.
Key specs include aluminum armoured gland material, 1-1/2" NPT thread size and NPT thread type, armor range 1.59–1.88", outer sheath range 1.70–1.96", NEC/CEC compliance, Area classification for Hazardous/Classified Locations, and NEMA 4 protection. The catalog page and Eaton TECK150 11 datasheet provide comprehensive details for validation and cross-referencing in design reviews.
Yes. TECK150 11 is designed for hazardous and classified locations with NEC/CEC compliance and a Class II, Division 1 rating context indicated in its specifications. It supports safe termination of armored TECK cables in environments with flammable dust or fibers, reducing commissioning risk and helping meet regulatory requirements.
The gland aligns with NEC/CEC standards, supports Hazardous/Classified Locations, and carries a NEMA 4 rating for enclosure protection. This combination ensures regulatory compliance, environmental sealing, and suitability for industrial installations requiring proven performance in harsh conditions.
Documentation includes the Crouse-Hinds TECK catalog page, IF 1417 installation sheet for TECK cable fittings, and the Eaton TECK150 11 specification sheet. These resources help with procurement, accurate installation, and ongoing maintenance, supporting faster ROI and easier QA audits.