Eaton Crouse-Hinds TECK150 11S Cable Gland - Class II, Division 1
Part Number: TECK150 11S
Quick Summary
TECK150 11S cable gland provides robust armored sealing for TECK armored cable in hazardous locations. Installations in harsh industrial environments often struggle with leaks, corrosion, and varied cable diameters, which can slow projects and raise maintenance costs. This gland aligns with NEC/CEC standards, features Class II, Division 1 and Class III ratings, and carries a NEMA 4 enclosure rating to withstand washdowns and moisture ingress. By offering a 1-1/2 inch NPT thread and steel construction, it delivers a reliable, long-life seal in demanding conditions. Designed specifically for TECK armored cable, it complements rugged equipment while simplifying installation, inspection, and future upgrades. The result is safer installations, faster commissioning, and predictable total cost of ownership for plant engineers.
Product Information
Extended Description
TECK150 11S Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Steel, Outer sheath min/max: 1.70-1.96", General purpose, 1-1/2" NPT, Armor range min/max: 1.59-1.88"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK150 11S
UPC
782274117348
Product Length/Depth
4.6 in
Product Height
3.6 in
Product Width
3.6 in
Product Weight
3 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Steel
Thread Size
1-1/2"
Thread type
NPT
Armor (min/max)
1.59-1.88"
Outer sheath (min/max)
1.70-1.96"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK150 11S
Steel construction delivers rugged protection for TECK armored cables, reducing corrosion risk and mechanical damage in demanding installations. The business impact is longer service life and lower replacement costs, even in washdown environments. This is particularly relevant where armored cable needs secure, leak-tight seals with 1-1/2 in NPT connections. Feature: General purpose protection with a precise 1-1/2 in NPT thread. Business impact: simplifies sourcing and compatibility with common conduits, saving installation time and avoiding custom fittings. Application: can be used across a range of armored cable installations where standard NPT glands are required. Feature: Armor and sheath size tolerances, 1.59-1.88 in and 1.70-1.96 in respectively, ensure a consistent fit across TECK cables. Business impact: reduces retrofit costs and project rework. Application: suitable for diverse armoured cable diameters in industrial plants. Feature: NEC/CEC compliance with Class II, Division 1 and Class III ratings plus NEMA 4 protection. Business impact: regulatory alignment minimizes risk of noncompliance and maintenance downtime. Application: essential in chemical, mining, oil and gas environments. Feature: Easy installation and maintenance workflow with standard hardware; robust sealing supports longer intervals between service. Business impact: lowers labor costs, accelerates commissioning, and improves uptime. Application: scalable for plant expansions and retrofits. Feature: Availability of TECK catalog guidance and installation sheets (IF 1417) supports technicians in field and shop settings. Business impact: reduces misapplications and accelerates training. Application: essential for contractor and in-house teams.
Get a Quick Quote for a Eaton Crouse-Hinds TECK150 11S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK150 11S?
Enquire Now
FAQs
TECK150 11S requires threading into a compatible enclosure with a 1-1/2 in NPT interface. Confirm that the TECK armored cable outer sheath fits within 1.70-1.96 inches and the armor diameter is within 1.59-1.88 inches before installation. Tighten to seal and ensure the sealing path remains unobstructed for reliable ingress protection.
Key specs include steel construction for rugged use, 1-1/2 in NPT thread, armor range of 1.59-1.88 inches, and outer sheath range of 1.70-1.96 inches. It is rated for NEC/CEC compliance with Class II, Division 1 and Class III, and a NEMA 4 enclosure, making it suitable for hazardous and washdown environments.
Yes. TECK150 11S is designed to meet NEC/CEC Class II, Division 1 requirements and offers a NEMA 4 rating, which is well-suited for hazardous locations common in chemical processing facilities. Its steel armoured construction and precise cable fit help ensure compliant, durable sealing in demanding chemical environments.
TECK150 11S adheres to NEC/CEC standards, features Class II, Division 1 and Class III ratings, and is a NEMA 4 enclosure product. These certifications collectively support compliance for hazardous locations, including chemical and mining applications, while maintaining reliable enclosure integrity.
The steel armoured gland design reduces corrosion and wear, lowering replacement and maintenance costs over time. Its durable seal and standard 1-1/2 in NPT thread simplify compatibility with common enclosures, accelerating commissioning and reducing labor costs. Over a plant lifecycle, these factors contribute to a favorable total cost of ownership and predictable maintenance planning.