Eaton TECK200 13 Cable Gland - Hazardous Class II/III

Part Number: TECK200 13
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
TECK200 13

Quick Summary

TECK200 13 cable gland provides armored, seal-tight entry for TECK cables in hazardous locations. When selecting fittings for rugged industrial environments, engineers often face inconsistent sealing and time-consuming assembly. This gland delivers reliable containment with aluminum construction, a 2" NPT thread, and precise armor/outer sheath fits. It is certified for NEC/CEC hazardous locations with Class II, Division 1 and Class III ratings, and carries a NEMA 4 enclosure protection, supporting safe operation in wet or dusty environments. By pairing it with TECK armored cable, you gain installation efficiency, reduced maintenance, and long-term cost savings. Use this gland where durability, compatibility, and regulatory compliance are essential to uptime and personnel safety.

Product Information

Extended Description

TECK200 13 Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Aluminum, Outer sheath min/max: 1.90-2.19", General purpose, 2" NPT, Armor range min/max: 1.79-2.11"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK200 13
UPC
782274116792
Product Length/Depth
4.82 in
Product Height
4 in
Product Width
4 in
Product Weight
11.05 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Aluminum
Thread Size
2"
Thread type
NPT
Armor (min/max)
1.79-2.11"
Outer sheath (min/max)
1.90-2.19"
Feature aluminum body and TECK armored design → Improved durability and corrosion resistance in harsh environments → Ideal for robust automation and packaging lines where fittings must endure vibration and exposure. Feature 2" NPT thread → Faster, standard-conduit compatible installations with fewer adapters, reducing field labor and potential leak paths → Suitable for control panels and junction boxes in hazardous zones. Feature armor range 1.79-2.11" and outer sheath range 1.90-2.19" → Precise fit for TECK armored cable, minimizing movement and protecting insulated conductors → Lower risk of abrasion, shortening commissioning time. Feature general purpose protection with NEMA 4 and NEC/CEC certifications → Regulatory compliance and weather/water resistance → Peace of mind for mining, chemical, and industrial facilities. Feature aluminum material → Lightweight yet sturdy, easing handling during installation and future maintenance checks → Better total cost of ownership for asset-intensive environments. Installation compatibility with TECK catalog pages and IF 1417 instructions → Streamlined procurement and standardized maintenance practices → Reduces downtime by providing clear, manufacturer-backed guidance.

Get a Quick Quote for a Eaton Crouse-Hinds TECK200 13

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds TECK200 13? Enquire Now

FAQs

TECK200 13 is engineered for TECK armored cable systems, featuring a 2" NPT gland with aluminum construction and armoured design. It accommodates armor in the range of 1.79 to 2.11 inches and outer sheath in the range of 1.90 to 2.19 inches, ensuring a secure fit and reliable seal in demanding environments. This compatibility minimizes field modification and simplifies procurement for projects employing TECK cables.
The TECK200 13 carries NEC/CEC compliance for hazardous/classified locations with Class II, Division 1 and Class III ratings, and a NEMA 4 protection level. These certifications support safe operation in potentially explosive dust and hazardous liquids environments, providing regulatory confidence for facilities such as chemical plants, mining operations, and offshore installations.
While designed for hazardous locations, the TECK200 13 also offers general purpose protection and weather resistance (NEMA 4). It can be deployed in non-hazardous settings where robust sealing and corrosion resistance are beneficial, but users should verify that the application aligns with the product’s certification scope and environmental ratings.
Plan for a 2" NPT connection and verify cable armor dimensions (1.79–2.11 in) and outer sheath size (1.90–2.19 in) before mounting. Refer to CAT 1417 TECK Cable Fittings and the TECK catalog page for installation guidance. Use appropriate torque and sealing practices to maintain NEMA 4 integrity and ensure compliant routing in conduit systems.
The TECK200 13 provides durable sealing and a robust armored interface, reducing gasket failures and leak paths in harsh environments. Its authorized certifications and standardized dimensions support faster commissioning, lower maintenance costs, and improved uptime for mission-critical automation, ultimately delivering a favorable total cost of ownership for asset-intensive facilities.