Eaton TECK200 13S Cable Gland - NEMA 4 Hazardous Locations
Part Number: TECK200 13S
Quick Summary
TECK200 13S cable gland is designed to seal armored TECK cables in industrial wiring installations. In hazardous locations, installers contend with ingress risks and mis-sized fittings that can trigger costly downtime. This gland meets NEC/CEC requirements and carries a NEMA 4 rating, along with Class II, Division 1 and Class III hazardous-location approvals. Its 2 inch NPT thread, steel construction, and armoured design simplify field installation and improve long-term protection. For OEMs and maintenance teams, the result is faster commissioning, reduced maintenance, and compliant, scalable automation deployments. Common applications include factory automation, chemical processing, and mining, where rugged TECK armored cables require dependable sealing.
Product Information
Extended Description
TECK200 13S Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Steel, Outer sheath min/max: 1.90-2.19", General purpose, 2" NPT, Armor range min/max: 1.79-2.11"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK200 13S
UPC
782274117362
Product Length/Depth
4.82 in
Product Height
4 in
Product Width
4 in
Product Weight
5.66 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Steel
Thread Size
2"
Thread type
NPT
Armor (min/max)
1.79-2.11"
Outer sheath (min/max)
1.90-2.19"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK200 13S
Feature: Armoured TECK gland construction delivers robust ingress protection and reliable strain relief for armored cable assemblies. Benefit: reduces moisture ingress, shield wear, and field repairs, lowering maintenance costs and downtime. Application: designed for TECK armored cables with outer sheath 1.90-2.19 inches and armor 1.79-2.11 inches, ensuring a precise, secure fit across common installation diameters. Feature: 2 inch NPT thread standard simplifies mounting to compatible enclosures and conduits, accelerating commissioning. Benefit: eliminates the need for adapters and reduces installation torque variability, improving repeatability. Application: ideal for new builds and retrofit projects in industrial facilities. Feature: Steel construction provides rugged durability for heavy industrial environments. Benefit: longer service life, reduced replacement cycles, and resilience under thermal cycling. Application: mining, chemical processing, and outdoor installations where abrasion and corrosion resistance matter. Feature: Armor and outer sheath dimensional ranges ensure consistent seal performance with TECK cables across nominal differences. Benefit: prevents over-tightening or under-sealing, preserving enclosure integrity. Application: OEM panel and harness standardization across multiple projects. Feature: Hazardous-location certifications NEC/CEC, Class II Division 1, Class III, and NEMA 4 enable regulatory compliance. Benefit: simplifies safety audits and accelerates approvals in regulated facilities. Application: installations in Hazardous/Classified Locations such as manufacturing and energy sectors. Feature: NEMA 4 rated protection adds water and dust resistance for indoor and outdoor deployments. Benefit: reduces maintenance frequency and extends gland life in harsh environments. Application: industrial automation, oil and gas, and mining environments where reliability is critical.
Get a Quick Quote for a Eaton Crouse-Hinds TECK200 13S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK200 13S?
Enquire Now
FAQs
TECK200 13S requires standard 2" NPT mounting to compatible enclosure openings. Ensure the outer sheath fits within 1.90-2.19" and armor within 1.79-2.11" for a secure seal. Use appropriate gasketing and ensure threads are clean and lubricated to achieve proper torque without over-tightening.
TECK200 13S carries NEC/CEC compliance with a NEMA 4 rating and hazardous-location approvals including Class II, Division 1 and Class III. It is suitable for area classifications such as Hazardous/Classified Locations, supporting compliance audits and safe operation in regulated facilities.
Yes. The gland’s 2" NPT armoured design and steel construction suit rugged factory automation, mining, and chemical processing environments. Its armor and sheath size ranges ensure reliable sealing of TECK armored cables, reducing maintenance needs and boosting uptime in demanding applications.
TECK200 13S is specifically designed for TECK armored cables with defined armor and outer sheath ranges (1.79-2.11" and 1.90-2.19" respectively), a 2" NPT thread, steel material, and hazardous-location certifications. This combination delivers enhanced protection, easier installation, and regulatory readiness compared with generic glands.
The gland offers durable protection that reduces ingress-related wear and field repairs, extending gasket life and lowering maintenance frequency. Its standardized size and mounting simplify procurement and installation, enabling faster commissioning and predictable lifecycle costs, which translates to improved total cost of ownership for harsh-environment installations.