Eaton Crouse-Hinds TECK200 14S Cable Gland - Hazardous/Classified Locations
Part Number: TECK200 14S
Quick Summary
The TECK200 14S cable gland by Eaton Crouse-Hinds seals TECK armored cable in hazardous or classified locations. Engineers often battle ingress, corrosion, and downtime in harsh environments, and a robust gland helps reduce unscheduled outages. It meets NEC/CEC standards, carries a NEMA 4 rating, and is approved for Hazardous/Classified Locations (Class II, Division 1; Class III). With steel construction and a 2" NPT thread, it integrates smoothly into panels, enclosures, and TECK cable runs, boosting installation efficiency and lifecycle cost. This combination supports safer, compliant automation deployments in oil, gas, mining, and manufacturing facilities.
Product Information
Extended Description
TECK200 14S Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Steel, Outer sheath min/max: 2.10-2.37", General purpose, 2" NPT, Armor range min/max: 1.99-2.28"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK200 14S
UPC
782274117386
Product Length/Depth
4.82 in
Product Height
4 in
Product Width
4 in
Product Weight
4.9 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Steel
Thread Size
2"
Thread type
NPT
Armor (min/max)
1.99-2.28"
Outer sheath (min/max)
2.10-2.37"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK200 14S
Armoured steel construction provides rugged mechanical protection for TECK armored cables, reducing wear in abrasive environments. The business impact is a lower total cost of ownership due to fewer mid-life replacements and less downtime. This is particularly valuable in mining, metal processing, and heavy manufacturing where cable runs endure constant handling and exposure to harsh materials. 2 inch NPT threading ensures robust, leak-free mounting with standard conduit systems. The business impact is faster installation and fewer field adaptations, which shortens project schedules. In practice, technicians can integrate the TECK200 14S with commonly available fittings in control panels and switchgear assemblies. Armor and sheath specifications (armor 1.99–2.28 inches; outer sheath 2.10–2.37 inches) guarantee sealing across a range of TECK cables. The business impact is consistent ingress protection and predictable performance across cable diameters, reducing rework. This is especially advantageous in environments with temperature cycling and vibration, such as refineries and pulp and paper facilities. NEC/CEC compliance, NEMA 4 rating, and Hazardous/Classified Location approvals help with regulatory alignment. The business impact is easier certification processes and reduced risk during audits. This supports faster project approvals and safer installations in oil, gas, chemical plants. General-purpose, TECK armored cable gland with a 4.82 in depth and 4 in width provides stable mounting in enclosures and panels. The business impact is predictable fit and easier mounting in tight spaces, saving time during assembly. This is beneficial for retrofits and new builds where space is at a premium.
Get a Quick Quote for a Eaton Crouse-Hinds TECK200 14S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK200 14S?
Enquire Now
FAQs
TECK200 14S is designed for TECK armored cables in hazardous or classified locations, offering robust sealing and a reliable 2" NPT mount. It aligns with NEC/CEC requirements and a NEMA 4 rating, making it suitable for panels, enclosures, and field fittings in demanding environments. Compatibility with standard TECK armor ensures straightforward integration into existing installations.
TECK200 14S carries NEC/CEC compliance and is approved for Hazardous/Classified Locations, including Class II Division 1 and Class III. Its NEMA 4 rating complements these certifications by ensuring enclosure protection against ingress. For project approvals and ongoing audits, these certifications simplify compliance workflows and reduce risk when wiring in hazardous areas.
Yes, TECK200 14S is designed for robust mounting with a 2" NPT thread, enabling standard conduit compatibility. Its footprint—approximately 4.82 in length/depth and 4 in width with a weight around 4.9 lb—facilitates stable installations in control panels and compact enclosures. Plan for adequate headroom around the gland to ensure proper tightening and cable access during maintenance.
Available resources include the Crouse-Hinds TECK catalog page, IF 1417 installation instructions for TECK cable fittings, and the Eaton TECK200 14S specification sheet. These documents provide dimensional data, installation steps, and compatibility guidance to streamline procurement, quoting, and field assembly.
The gland provides reliable ingress protection, durable steel armor, and regulatory compliance, which together reduce maintenance cycles and risk of unplanned downtime. In addition, the standardized 2" NPT mounting and documented installation procedures shorten commissioning times, lower lifecycle costs, and support safer, compliant expansions of automation networks in oil, gas, mining, and chemical processing.