Eaton Crouse-Hinds TECK200 16S Cable Gland - Class II, Div 1
Part Number: TECK200 16S
Quick Summary
TECK cable gland from Eaton Crouse-Hinds provides rugged sealing for armored TECK cables in hazardous industrial environments. Eliminate installation delays caused by mismatched fittings and rework with a 2" NPT gland designed to fit armor from 2.39" to 2.66" and outer sheath from 2.50" to 2.75". This solution carries NEC/CEC safety with Class II, Division 1 and Class III ratings and a NEMA 4 enclosure rating, supporting reliable operation in demanding conditions. Coupled with compatible TECK armored cable fittings and accessible installation guides, it helps streamline procurement, compliance, and maintenance across automation projects.
Product Information
Extended Description
TECK200 16S Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Steel, Outer sheath min/max: 2.50-2.75", General purpose, 2" NPT, Armor range min/max: 2.39-2.66"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK200 16S
UPC
782274117409
Product Length/Depth
4.87 in
Product Height
4.4 in
Product Width
4.4 in
Product Weight
4.85 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Steel
Thread Size
2"
Thread type
NPT
Armor (min/max)
2.39-2.66"
Outer sheath (min/max)
2.50-2.75"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK200 16S
Feature: Armoured steel gland with a 2" NPT thread; Business Impact: Delivers robust sealing for TECK armored cables, reducing ingress for better reliability in vibration-prone environments; Application: Best in general purpose and hazardous locations within industrial automation lines. Feature: Precise armor (2.39-2.66") and outer sheath (2.50-2.75") ranges; Business Impact: Ensures correct fit, lowering commissioning time and inventory mismatch; Application: Essential for safe, fast field installs on armored cable runs. Feature: NEC/CEC compliance with NEC hazardous ratings Class II, Division 1 and Class III; Business Impact: Lowers regulatory risk and accelerates approvals in regulated facilities; Application: Chemical plants, refineries, and mining sites. Feature: NEMA 4 enclosure rating; Business Impact: Enables outdoor and wet-location reliability with long-term protection; Application: Outdoor electrical rooms and process enclosures. Feature: General purpose protection type in TECK armored cable systems; Business Impact: Streamlines compatibility and spare-part planning; Application: Retrofit projects and new installations. Feature: Included installation resources (catalog page, IF 1417 instructions, spec sheet); Business Impact: Reduces learning curve and speeds up field work; Application: Procurement teams and maintenance crews in automation environments.
Get a Quick Quote for a Eaton Crouse-Hinds TECK200 16S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK200 16S?
Enquire Now
FAQs
TECK200 16S is designed to mate with TECK armored cables and related fittings in armored cable systems. Its 2" NPT thread size and precise armor/outer sheath ranges ensure a proper, secure connection, reducing rework and leakage risk. For field installs, confirm the armor range (2.39"–2.66") and sheath range (2.50"–2.75") prior to assembly, and reference Eaton's installation sheets for best practices.
Key specs include a steel armoured gland with a 2" NPT thread, armor range 2.39–2.66" and outer sheath range 2.50–2.75". The unit weighs 4.85 lb and measures about 4.87 in long with a 4.4 in width and height. The gland is intended for general purpose protection in TECK armored cable systems and supports NEC/CEC compliance.
Yes. TECK200 16S carries NEC/CEC standards with NEC hazardous ratings Class II, Division 1 and Class III, making it suitable for hazardous/classified locations. It also holds a NEMA 4 rating, suitable for exposed outdoor or moisture-prone environments. These certifications help ensure compliant installation in chemical plants, refineries, or other demanding facilities.
Industries requiring armored cable seals in hazardous locations, including oil & gas, mining, and chemical processing, benefit most. The gland’s exact armor and sheath ranges ensure reliable fit, while NEC/CEC and NEMA 4 ratings protect against ingress and environmental exposure. The result is improved uptime, lower maintenance costs, and safer enclosure integrity.
The gland’s precise sizing reduces field rework and component mismatches, shortening installation times and reducing downtime. Availability of installation instructions, catalog pages, and specification sheets supports quicker commissioning, easier spare-part planning, and predictable long-term costs, translating to favorable total cost of ownership in automation projects.