Eaton TECK250 18 Cable Gland - Hazardous Locations
Part Number: TECK250 18
Quick Summary
TECK250 18 Cable Gland from Eaton seals armored TECK cables for hazardous and classified locations. Many engineers struggle to find glands that meet NEC/CEC, Class II Division 1 requirements, along with a robust 2-1/2 inch NPT thread, without compromising cable integrity. This gland is engineered for harsh environments, delivering a rugged aluminum armoured seal with reliable performance across outer sheath 2.58–2.84 inches and armor range 2.24–2.75 inches. It supports general purpose protection while simplifying field installations and maintenance. When you specify Eaton TECK, you gain predictable sealing, reduced rework, and compliance confidence for industrial facilities, chemical plants, and mining operations.
Product Information
Extended Description
TECK250 18 Eaton Crouse-Hinds: Eaton Crouse-Hinds series TECK cable gland, TECK armoured cable, Armoured gland, Aluminum, Outer sheath min/max: 2.58-2.84", General purpose, 2-1/2" NPT, Armor range min/max: 2.24-2.75"
Product Name
Eaton Crouse-Hinds series TECK cable gland
Catalog Number
TECK250 18
UPC
782274116839
Product Length/Depth
6.3 in
Product Height
4.75 in
Product Width
4.75 in
Product Weight
3.17 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III
NEMA Rating
4
Protection type
General purpose
Cable type
TECK armored
Gland type
Armoured
Material
Aluminum
Thread Size
2-1/2"
Thread type
NPT
Armor (min/max)
2.24-2.75"
Outer sheath (min/max)
2.58-2.84"
Crouse-Hinds series TECK catalog page
IF 1417 - TECK Cable Fittings
Eaton Specification Sheet - TECK250 18
Feature aluminum body and armoured design delivers corrosion resistance and lighter weight, reducing installation time and handling risk in harsh environments. Business impact: faster commissioning, lower labor cost, and extended gland life. Application: control panels, enclosures, and outdoor installations in chemical plants or mining sites. Feature 2-1/2 inch NPT thread compatibility ensures fitting compatibility with existing piping and conduit solutions. Business impact: minimizes hardware inventory and eliminates need for adapters. Application: field installations and retrofit projects with TECK armored cable systems. Feature TECK armored cable compatibility and armoured gland design provide secure sealing for hazardous locations. Business impact: enhanced safety and regulatory compliance, reducing potential leak paths and maintenance calls. Application: oil, gas, and industrial processing facilities operating under NEC/CEC standards. Feature NEMA 4 rating adds environmental protection against dust, water, and washdown exposure. Business impact: rugged performance in outdoor or washdown environments, lowering replacement frequency. Application: harsh plant floors, outdoor enclosures, and exposed conduits. Feature documented specifications for outer sheath and armor ranges (2.58–2.84 in; 2.24–2.75 in) enable precise selection. Business impact: predictable fit, fewer field reworks, and faster procurement. Application: projects requiring exact gland-to-cable matching in aerospace, automotive, and process facilities. This combination of material, dimensions, and standards supports scalable, compliant deployments across multiple TECK armored cable applications.
Get a Quick Quote for a Eaton Crouse-Hinds TECK250 18
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds TECK250 18?
Enquire Now
FAQs
TECK250 18 Cable Gland is designed for TECK armored cables with a 2-1/2 inch NPT thread. It accommodates armoured conductors with an outer sheath of 2.58–2.84 inches and armor within 2.24–2.75 inches. Use this gland for general purpose sealing in industrial installations using TECK armored cable in harsh environments.
TECK250 18 is designed to meet NEC/CEC standards for general purpose protection and is suitable for hazardous/classified locations. It carries a NEMA 4 rating for weather and washdown resistance and is applicable to Class II Division 1 and Class III environments, ensuring regulatory compliance in demanding facilities.
Installation uses the 2-1/2 inch NPT threaded gland to secure TECK armored cables. Verify outer sheath and armor ranges (2.58–2.84 inches and 2.24–2.75 inches) before mounting. Follow Eaton installation guidance (IF 1417) for TECK Cable Fittings to ensure proper seals, mating with panels, and compliance in hazardous locations.
The gland package reports a length of 6.3 inches, width and height of 4.75 inches each, and a product weight of 3.17 pounds. These dimensions support predictable enclosure fitment and straightforward handling during installation and maintenance in industrial environments.
Ideal for industries using TECK armored cables in hazardous locations, including chemical processing, oil & gas, mining, and heavy manufacturing. The gland’s aluminum construction, NPT threading, and NEMA 4 rating support durable, compliant sealing in exposed, washdown, and harsh environment settings, reducing downtime and maintenance needs.